    WINE-MATE Split System Installation, Operation & Care Manual VINO-1500SSL VINO-2500SSL VINO-4500SSL VINO-6500SSL V V i i n n o o t t e e m m p p I I n n t t e e r r n n a a t t i i o o n n a a l l C C o o r r p p . . w w w w w w . . w w i i n n e e m m a a t t e e . . c c o o m m RE AD A ND SAVE THESE I NSTRUCTIONS ...

  • Vinotemp WM-650SCU - page 2

    - 1 - TABLE OF CONTENTS Important Safety Info rmation…..........................................2 Feature Description…………………………….……………..3 Cellar Construction.…………………………….……………..6 Installer’s Instruction…………….…..….……..……………..7 Temperature Control & Hu ...

  • Vinotemp WM-650SCU - page 3

    - 2 - Important Safety Information • DO NOT USE A GROUND FAUL T INTERRUPTER (GFI). • A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED. ...

  • Vinotemp WM-650SCU - page 4

    - 3 - Feature Description • Wine-Mate split cooling system s VINO1500-6500SSL are designed and used to provide a cold temperature between 50~65 ° F for a properly insulated wine room at a normal environment. • The wine room will maintain hum idity of 50~70% RH even when the environment becomes dry and humid. These temperatures and humilities a ...

  • Vinotemp WM-650SCU - page 5

    - 4 - Fig. 1.1 WM15-25SFCL Evaporator Unit Fig. 1.2 WM45-65SFCL Evaporator Unit NOTES: LIQUID AND SUCTION LIN ES MAY DIFFER FROM WHAT ARE SHOWN HERE, PLEASE CHECK ON THE UNITS FOR PROPER INSTALLATION. ...

  • Vinotemp WM-650SCU - page 6

    - 5 - Fig. 1.3 WM150-450SCU Condensing Unit Fig. 1.4 WM-650SCU Condensing Unit ...

  • Vinotemp WM-650SCU - page 7

    - 6 - Cellar Construction This is only a guide and shall be c onsidered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier s hall be installed on the warm side of the insulation ...

  • Vinotemp WM-650SCU - page 8

    - 7 - Installer’s Instruction Federal law requires that WINE--M ATE split cooling systems be installed by an EPA certified refrigeration technician. WINE-MATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed, charged and tested the system. Proper installation is crit ...

  • Vinotemp WM-650SCU - page 9

    - 8 - 1. Condensing Unit • Place the condensing units WM150- 650SCU in a properly ventilated location. If it is not, heat exhaust ed by the condensing unit will build up and the cooling system will not operate properly. • Leave minimum 5 feet clearance for the exhaust side and leave minimum 1 foot clearance for the fresh air intake side. • Co ...

  • Vinotemp WM-650SCU - page 10

    - 9 - • High side pressure: 130 -150 psig at 75 -90 ° F ambient temperatures The line sizes and refrigerant charges are listed as follows. MODEL REFRIGERATION LINES LIQUID LINE SUCTION LINE DRAIN LINE CHARGE VINO-1500SSL < 50 FT 1/4" OD 3/8” OD 1/2” OD R134a/ 15 OZ VINO-2500SSL < 50 FT 1/4" OD 3/8” OD 1/2” OD R134a/ 20 OZ ...

  • Vinotemp WM-650SCU - page 11

    - 10 - 6. Valve Operation SPINDLE BACK POSITION SPINDLE FRONT POSITION SPINDLE MIDDLE POSITION Fig. 2.2 Valve Operation Back Position : Process and manometer port closed for normal operation Front Position : Main connection to liquid or suction line closed Middle Position : All ports open for vacuum, charge and measurement 7. Electrical Wiring Fig. ...

  • Vinotemp WM-650SCU - page 12

    - 11 - Fig. 2.4 VINO1500-4500SSL Wiring Diagram (DIGITAL CONTROLLER) Fig. 2.5 VINO6500SSL Electrical Wiring Diagram (VTSTAT) ...

  • Vinotemp WM-650SCU - page 13

    - 12 - Fig. 2.6 VINO6500SSL Electrical Wiri ng Diagram (DIGITAL CONTROLLER) 8. Use of the adjustable low pr essure control (if applicable) Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig It may need to adjust the setting in the field to get the right cycle time. Fig. 2.7 Adjustable Pressure Control ...

  • Vinotemp WM-650SCU - page 14

    - 13 - 9. Condensing Unit Troubleshooting Unit not running a. Incorrect power supply b. Incorrect or loose wiri ng s c. Failed components d. Liquid refrigerant in the compressor e. Low pressure switch shutting down the system a. Check for proper voltage b. Check all wirings a nd co nnections c. Check start relay, start ca pacitor, overload protecto ...

  • Vinotemp WM-650SCU - page 15

    - 14 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantit y of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize th ...

  • Vinotemp WM-650SCU - page 16

    - 15 - Dip-switch description (See detail in VSTAT instruction ) 1, 2 differential: added to the Set Point, es tablishes the temperature threshold, measured by the regulation probe, beyond which the co mpressor is activated; 3 compressor safety function: OFF - function disabled; ON - function enabled; 4 temperature display: OFF - display ed in °C; ...

  • Vinotemp WM-650SCU - page 17

    - 16 - If the function is enabled, the compressor is not energized for three minutes after controller power up. The function is also active in hot-gas defrost mode. 5) LED & Display Messages 1. LED off 2. LED on 3. LED blinking 0.5s on/0.5s off 4. LED blinking 0.5s on/1.5s off 5. Display A1 6. Display A2 1. Compressor and defrost deactivated 2. ...

  • Vinotemp WM-650SCU - page 18

    - 17 - 2) Alarm Signals 2.1 Code Description 2.2 Alarm Recovery Probe alarms P1”, start a few seconds afte r the fault in the re lated probe; they automatically stop a few seconds afte r the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms “HA”, “LA” automatically stops as soon as the tem p ...

  • Vinotemp WM-650SCU - page 19

    - 18 - 2. The value of the set point will be di splayed and the “°C” or “°F” LED starts blinking; 3. To change the Set value, push the o or n arrows within 10s. 4. To memorize the new set point value, push the SET key again or wait 10s. 4) Humidity Adjustment The parameter Fon is used to adjust the humidity in the wine cabinet. The higher ...

  • Vinotemp WM-650SCU - page 20

    - 19 - Care Guide In general, always unplug system or di sconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty. • Plug ...

  • Vinotemp WM-650SCU - page 21

    - 20 - User’s Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration servic e person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1.Unit not running a. No power b. Power cord unplugged c. Setting higher than ambient temperature d. Defrost li ...

  • Vinotemp WM-650SCU - page 22

    - 21 - e. Malfunctioning fans f. Improper evaporator or condenser airflow g. Dir ty C ondenser h. Iced evaporator i. Refrigeration system restriction j. Sealed system problem k. Undercharge or overcharge intake side e. Check for both evaporator and condenser fans f. Check for air re strictions g. Clean condenser h. Defrost and reset temperature i. ...

  • Vinotemp WM-650SCU - page 23

    - 22 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com ...

  • Vinotemp WM-650SCU - page 24

    - 23 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and se rial numbers in the space provided: Model_____________ _________________________ __ _________________ Serial No.___________________ ___________________ ________________ Attach your purchase receipt to this owner’s manual. 1. Limited Warranty VIN ...

  • Vinotemp WM-650SCU - page 25

    - 24 - VINOTEMP will, at its discret ion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect. 2. Limitation of Implied Warranty VINOTEMP’S SOLE LIABI LITY FOR ANY DEFECTIVE PRODUCT ...

メーカー Vinotemp カテゴリー Refrigerator

Vinotemp WM-650SCUのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- WM-650SCUの取扱説明書
- Vinotempの製品カード
- パンフレット
- またはVinotemp WM-650SCUの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vinotemp WM-650SCUの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vinotemp WM-650SCUの取り付け説明書、サービスマニュアル、簡易説明書、またはVinotemp WM-650SCUのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vinotemp WM-650SCUの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Vinotemp WM-650SCUデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVinotemp WM-650SCUを使用するのを助ける技術的文書のことです。説明書は通常、全てのVinotemp WM-650SCUユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vinotempの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vinotemp WM-650SCUの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVinotemp WM-650SCUの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vinotemp WM-650SCUに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vinotemp WM-650SCUデバイスの基本機能を使うにあたってのヒント。 Vinotemp WM-650SCUのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vinotemp WM-650SCUに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVinotemp WM-650SCUのメーカー/サービスへの連絡先に関する情報。

Vinotemp WM-650SCUについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVinotemp WM-650SCUの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVinotemp WM-650SCUで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)