    P art Number 550-141-816/0798 Contents I . New installation .......... 2 II . Existing installation .... 4 III. Water and steam trim components .................. 4 IV. Gas piping ................... 5 V. Wiring ........................... 5 Sequence of operation ..... 8 Wiring procedure .............. 8 VI. Leak test procedure ... 1 0 VII. Operati ...

  • Weil-McLain 6-20 Series - page 2

    P art Number 550-141-816/0798 2 LGB -6 to LGB -20 Ser ies 2 – Control S upplement I New installation 1 . R emove all bu r ners from base bo x assembly . Remo ve 3.95 mm natural gas main burner orifices in manifold. Install 2.40 mm propane gas main burner orifices. Use pipe dope sparingly only on male ends. Use pipe dope compatible with propane ga ...

  • Weil-McLain 6-20 Series - page 3

    P art Number 550-141-816/0798 3 CSD-1 Control System – Propane gas Figure 1 Pilot burner assembly , typical Figure 2 Main flame sensor assembly I New installation – continued ...

  • Weil-McLain 6-20 Series - page 4

    P art Number 550-141-816/0798 4 LGB -6 to LGB -20 Ser ies 2 – Control S upplement 1 . These instructions are for use with Propane Control Cartons as listed in Gas Control Arrangement, T able 2 (page 2). 2 . Remove jacket door(s) and access panel(s). 3 . Disconnect wiring and tubing from existing pilot burner and main flame sensor . 4 . Remove all ...

  • Weil-McLain 6-20 Series - page 5

    P art Number 550-141-816/0798 5 CSD-1 Control System – Propane gas IV Gas piping 1 . Contact gas supplier to siz e pip es, tanks and regulator . a. Inlet gas pressure to manual main shut-off gas valve — minimum 11” W .C., maxim um 13” W .C. b. If pressure to gas valv e exc eeds 13” W .C., install 100% lock-up gas pressure regulat or upstr ...

  • Weil-McLain 6-20 Series - page 6

    P art Number 550-141-816/0798 6 LGB -6 to LGB -20 Ser ies 2 – Control S upplement P art Number 550-141-816/0798 7 CSD-1 Control System – Propane gas Figure 3 Wiring diagram SENSOR MAIN FLAME FIRING RATE CONTROL (WHEN USED) STAGE COMBINATION VALVE W/REGULATOR MAIN GAS VALVE - TWO MAIN GAS VALVE TERMINAL. FIELD WIRED TO GAS VALVE OR FIRING IGNITI ...

  • Weil-McLain 6-20 Series - page 7

    P art Number 550-141-816/0798 8 LGB -6 to LGB -20 Ser ies 2 – Control S upplement 1 . Operating control begins startup sequence. a. Limit control contacts are closed. 2 . Pilot proving module energized. a. Pilot solenoid opens. b. Pilot ignition spark begins. c . Pilot ignites. d. Pilot proves. 3 . Main flame proving module energized from pilot p ...

  • Weil-McLain 6-20 Series - page 8

    P art Number 550-141-816/0798 9 CSD-1 Control System – Propane gas Figure 5 Field wiring diagram ...

  • Weil-McLain 6-20 Series - page 9

    P art Number 550-141-816/0798 10 LGB -6 to LGB -20 Ser ies 2 – Control S upplement 1 . Remove red (MV) and blue (PV) wires from main gas valve. 2 . Close main test firing valve attached to the manifold. 3 . Check that both leak test valves are closed and remove plugs. 4 . Attach manometer to first leak test valve. 5 . Open first leak test valve a ...

  • Weil-McLain 6-20 Series - page 10

    P art Number 550-141-816/0798 11 CSD-1 Control System – Propane gas This document is intended only as a supplement to the LGB Gas-Fired Boiler Manual . Follow all instructions in the Manual, including those regarding start-up (found in Section VIII, “Placing boiler in operation ”). A . This boiler is equipped with a pilot which must be lighte ...

  • Weil-McLain 6-20 Series - page 11

    P art Number 550-141-816/0798 12 LGB -6 to LGB -20 Ser ies 2 – Control S upplement W eil-McLain 500 Blaine Street Michigan City , IN 46360-2388 http://www .weil-mclain.com VIII P arts list Figure 6 Ref . No. Descri ption Size Vendor /Part Nu mber Weil- McLain P art Number 1 Main flame sen sor Honeyw ell 392956 511-724- 274 Main bur ner with pilo ...

メーカー Weil-McLain カテゴリー Boiler

Weil-McLain 6-20 Seriesのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 6-20 Seriesの取扱説明書
- Weil-McLainの製品カード
- パンフレット
- またはWeil-McLain 6-20 Seriesの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Weil-McLain 6-20 Seriesの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Weil-McLain 6-20 Seriesの取り付け説明書、サービスマニュアル、簡易説明書、またはWeil-McLain 6-20 Seriesのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Weil-McLain 6-20 Seriesの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Weil-McLain 6-20 Seriesデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWeil-McLain 6-20 Seriesを使用するのを助ける技術的文書のことです。説明書は通常、全てのWeil-McLain 6-20 Seriesユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Weil-McLainの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Weil-McLain 6-20 Seriesの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWeil-McLain 6-20 Seriesの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Weil-McLain 6-20 Seriesに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Weil-McLain 6-20 Seriesデバイスの基本機能を使うにあたってのヒント。 Weil-McLain 6-20 Seriesのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Weil-McLain 6-20 Seriesに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWeil-McLain 6-20 Seriesのメーカー/サービスへの連絡先に関する情報。

Weil-McLain 6-20 Seriesについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWeil-McLain 6-20 Seriesの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWeil-McLain 6-20 Seriesで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)