Lennox Hearth SOLANA-BKの取扱説明書

26ページ 1.77 mb
ダウンロード

ページに移動 of 26

Summary
  • Lennox Hearth SOLANA-BK - page 1

    SOLANA-BK SOLANA-BN SA VE THESE INSTRUCTIONS FOR FUTURE REFERENCE This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation. Do not alter or modify the fireplace or its components under any cir - cumst ...

  • Lennox Hearth SOLANA-BK - page 2

    2 W ARNING NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flammable liquids a safe distance from the fireplace at all times. W ARNING The bottom refractory can be cra cked by excess ive abu se such as tossi ...

  • Lennox Hearth SOLANA-BK - page 3

    3 T AB LE O F C O NT E NT S Safety Rules .......................................Page 2 Introduction .......................................Page 3 Parts Required ..................................Page 3 Optional Equipment ............................Page 3 EP A Qualified .....................................Page 3 Operating The Fireplace .......... ...

  • Lennox Hearth SOLANA-BK - page 4

    4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Building A Fire (starting and maintaining a fire) T o start a fire, place several crumpled up balls of newspaper in the firebox. Place small dry pieces of kindli ng on top of the paper , criss-c rossing the kindling so that there are air spaces in between. Keep the fuel far back enough so t ...

  • Lennox Hearth SOLANA-BK - page 5

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5 Figure 1 - Outside air Register D. Wet wood Wet or tarred wood will smoulder and smoke instead of burning properly . Y our dealer can help you determine if you have properly seasoned wood for burning. E. Dirty or blocked chimney Check to make sure the chimney is clear and clean. If dirty call ...

  • Lennox Hearth SOLANA-BK - page 6

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 6 Caution: It is necessar y to remove the baffle from the top of the firebox before cleaning the chimney . Dealing With a Chimney Fire Regular chimney maintenance and inspection can preve nt chim ney fires. If you hav e a chim ney fire, follow these steps: 1. Close the fireplace glass doors ...

  • Lennox Hearth SOLANA-BK - page 7

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 7 REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractory . These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractory . If large cracks develop, then t ...

  • Lennox Hearth SOLANA-BK - page 8

    8 Marginal Location Wind Direction Location Not Recommended Outside Air Intake Facing the Wind Location Not Recommended Location Recommended Figure 6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. FIREPLACE INST ALLA TION Locating The Solana Fireplace A. The best location to install your fireplace is determined by considering the location o ...

  • Lennox Hearth SOLANA-BK - page 9

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 9 W ARNING When using a gas burner , it is mandatory to keep the chimney outside air register opened. Preinstallation Please Read Before Installing: 1. Before beginning the installation of your fireplace, read these safety tips and instal- lation instructions carefully to be sure you understand ...

  • Lennox Hearth SOLANA-BK - page 10

    Non-Combustible Material NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 10 Mantel A wood mantel, if installed, must be at least 48" (1.2 m) above the base of the fireplace ( see Figure 8B ) . There is no restriction regarding the length or the width of the mantel. Hearth Extension Requirements ( refer to Figures 8A and 8B ) A non-combu ...

  • Lennox Hearth SOLANA-BK - page 11

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 11 42” (1067 mm) 43” (1092 mm) 43” (1092 mm) 27-1/2” (699 mm) 10-5/8” (270 mm) 33” (838mm) 42-1/2” (1080 mm) 17-1/8” (435 mm) 28-5/16” (719 mm) F J 21-1/2” (546mm) E D OUTSIDE CHASE G H C L * Back Wa ll of Chase/Enclosur e In clu din g F ini sin g M ate ria ls if any Rough Fr ...

  • Lennox Hearth SOLANA-BK - page 12

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 12 Fireplace Side Insulated Chase Construction Fireplace Facing The fireplace should be framed using 2" x 3" (50mm x 75mm) or heavier lumber . Figure 9 on Page 11 shows the general framing layout. Combustible materials must be installed flush with the fireplace facing. They may not ...

  • Lennox Hearth SOLANA-BK - page 13

    13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 12 - External Air Intake (Detail A) (Detail C) Outside Air Assembly (Fireplace and AC Chimney) The outside air assembly is mandator y for the fireplace and the AC chimney . During operation, the fireplace requires air for combustion and draws air out of the house. It may starve other ...

  • Lennox Hearth SOLANA-BK - page 14

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 14 INST ALLA TION OF THE BLOWER KIT MODEL UZY5 NOTE: This blower kit can easily be installed when the fireplace has a pre-installed junction box. Y ou just have to plug them in. Rating: 120 Volts, 60Hz, .63A. The blowers have magnetic blower mounts. The junction box (factory installed on approv ...

  • Lennox Hearth SOLANA-BK - page 15

    15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CHIMNEY SYSTEM GENERAL INFORMA TION The Sol ana™ firep lace is listed only with Security Chimneys™ Interna- tional Ltd. chimney systems, models ASHT+ 8", S-2100+ 8", or AC 8". Do not connect the fireplace to a masonry chimney , chimney liner , or other brand of factory-bu ...

  • Lennox Hearth SOLANA-BK - page 16

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 16 CHIMN EY INST ALLA TION INSTR UCTIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 19 ) . Use a plumb-bob to line up the center of the holes. The hole sizes are indicated in T able 3 for the floor and ceiling holes and in T able 4 ( Page ...

  • Lennox Hearth SOLANA-BK - page 17

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 17 Roof Down Slope Hole Size SLOPE ASHT+ S-2100+ AC Roof Pitch 8" 8" 8" 0 * 14-3/8" (365mm) 16" (406mm) 15" (380mm) 2/12 14-5/8" (371mm) 16-1/4" (413mm) 15-3/8" (390mm) 4/12 15-1/4" (387mm) 16-7/8" (429mm) 16-1/8" (410mm) 6/12 16-1/8&qu ...

  • Lennox Hearth SOLANA-BK - page 18

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 18 Figure 24 Ch im ney 8” Elbow Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48" 8” & 48” 12 ” & 4 8 ” 1 8” & 4 8 ” 2 4 ” & 48 ” 36” & 48 ” 48” & 48 ” S e cu re T e m p A SH T + N o v ...

  • Lennox Hearth SOLANA-BK - page 19

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 19 ANGLED WALL RADIA TION SHIELD (RSM+, RSMI30, RSMI45) When traversing a combustible wall with the chimney at a 30° or 45° angle, an angled firestop and/or wall radiation shield must be installed. Only one is required ( Figure 27 ) . T able 6 gives recommended hole size for installing a wall ...

  • Lennox Hearth SOLANA-BK - page 20

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 20 Figure 29 - S-2100 Chimney Adaptor Chimney Adaptor - Canada only CHIMNEY ADAPTOR (S-2100+ / HT6000+) CANADA ONL Y The fireplace is normally supplied with a chimney adaptor suitable for the ASHT / HT6103+ chimney . If you want to install a S-2100+ / HT6000+ chimney , an adaptor is available ( ...

  • Lennox Hearth SOLANA-BK - page 21

    21 Fireplace Model Solana™ - Approved Venting Components 8" Diameter Chimney - Model ASHT+, S-2100+, HT6000+, HT6103+ or AC manufactured by Security Chimneys International only . Notes: 1. (Projet NovaT emp™) HT6000+ is equivalent to S-2100+ 2. (Projet NovaT emp™) HT6103+ is equivalent to ASHT+ 3. This appliance is equipped with the ASHT ...

  • Lennox Hearth SOLANA-BK - page 22

    22 Se cu re T em p™ A SH T+ H ig h T em p. I ns ul a te d St ai nl es s St ee l Ch im ne y 8" D iam ete r , Lis ted t o C AN / UC L-S 60 4 a nd UL -1 03H T a t 120 0° F Description Cat./ Part No. Lengths and Misc. Chimney Components 8" Length, 8" Dia., 8L8 8L8 12" Length, 8" Dia., 8L12 8L12 18" Length, 8" Dia., ...

  • Lennox Hearth SOLANA-BK - page 23

    23 CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation; Side wall: 18” (457 mm) Ceiling: 7 feet (2135 mm) measured from the base of the fireplace Fireplace enclosure : Bottom: 0” Side: 0” to spacer Back: 0” to spacer T op: Do not fill the space above the fireplace with any material, 7 ...

  • Lennox Hearth SOLANA-BK - page 24

    24 Item # Description Cat. No. 1 Refractory Baffle PR-SR2028 2 Back Refractory PR-SR2027 3 Right Side Refractory PR-SR2025D 4 Left Side Refractory PR-SR2025G 5 Bottom Refractory PR-SR1722 6 Front Refractory Ash Lip PR-SR2026 7 Log Support Grate H7706 8 T op Louver PR-SR15P 9 Bottom Louver PR-SR15P 10 Louver Hinges PR-PIVOT 11 Rigid Firescreen (Rig ...

  • Lennox Hearth SOLANA-BK - page 25

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 25 REPLACEMENT P ARTS - SOLANA™ P A I N T 18 1 2 3 4 6 7 9 8 10 10 12 11 13 15 16 14 17 19 20 21 22 5 ...

  • Lennox Hearth SOLANA-BK - page 26

    26 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number ________________________________________ The Date On Which Y our Fireplace Was Installed ___________________________ Y our Dealer's Name _________________________________________________ Y our Dealer's Phone Number ________ ...

メーカー Lennox Hearth カテゴリー Indoor Fireplace

Lennox Hearth SOLANA-BKのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SOLANA-BKの取扱説明書
- Lennox Hearthの製品カード
- パンフレット
- またはLennox Hearth SOLANA-BKの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lennox Hearth SOLANA-BKの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lennox Hearth SOLANA-BKの取り付け説明書、サービスマニュアル、簡易説明書、またはLennox Hearth SOLANA-BKのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lennox Hearth SOLANA-BKの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lennox Hearth SOLANA-BKデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLennox Hearth SOLANA-BKを使用するのを助ける技術的文書のことです。説明書は通常、全てのLennox Hearth SOLANA-BKユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lennox Hearthの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lennox Hearth SOLANA-BKの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLennox Hearth SOLANA-BKの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lennox Hearth SOLANA-BKに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lennox Hearth SOLANA-BKデバイスの基本機能を使うにあたってのヒント。 Lennox Hearth SOLANA-BKのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lennox Hearth SOLANA-BKに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLennox Hearth SOLANA-BKのメーカー/サービスへの連絡先に関する情報。

Lennox Hearth SOLANA-BKについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLennox Hearth SOLANA-BKの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLennox Hearth SOLANA-BKで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)