Renesas SH7600 Seriesの取扱説明書

36ページ 0.21 mb
ダウンロード

ページに移動 of 36

Summary
  • Renesas SH7600 Series - page 1

    2003.7.3 SuperH  Family E10A Emulator Additional Docume nt for User’ s Manual SH7630 E10A HS7630KCM02HE Renesas M icrocomput er Developm ent Envi ronment Sy stem SuperH  Family / SH7600 Series Specific G uide for t he SH763 0 E10A Emul ator Rev.1.00 ...

  • Renesas SH7600 Series - page 2

    Cautions Keep safety firs t in your circ uit designs! 1. Renesas Technology Corporat ion puts the ma ximum effort into making s emiconductor products better and more reliable, but there is always the possibility that trouble may occ ur with them. Troubl e with semi conductors may lead t o persona l injury, fire or property dama ge. Remember to give ...

  • Renesas SH7600 Series - page 3

    i Contents Section 1 Connecting the Emulator with the User System ................................1 1.1 Components of the Emulator ............................................................................................ 1 1.2 Connecting the E10A Em ulator with the User System ..................................................... 4 1.3 Installin ...

  • Renesas SH7600 Series - page 4

    ii ...

  • Renesas SH7600 Series - page 5

    1 Section 1 Connecting the Emulator with the User System 1.1 Components of the Emulator The SH7630 E10A emulator s upports the S H7630. Table 1.1 l ists the components of the e mulator. ...

  • Renesas SH7600 Series - page 6

    2 Table 1.1 Com ponents of t he Emulator (HS763 0KCM01H, HS7630KCM 02H, HS7630KCI01 H, or HS7630 KCI02H) Classi- fication Component Appearance Quan- tity Remarks Hard- ware Card emulator PC PC Card (PCMCIA) or (PCI) 1 HS7630KCM01H (PCMCIA: 14-pin t ype): Depth: 85.6 mm , Width: 54.0 mm, Height: 5.0 m m, Mass: 27.0 g HS7630KCM02H (PCMCIA: 36-pin t y ...

  • Renesas SH7600 Series - page 7

    3 For EMI countermeasure, us e the ferrite core by c onnecting the user interface ca ble. When the user interface cable is connected with the emulator or us er system, connect the ferrite core in the us er system as shown i n figure 1.1. User interface cable Host computer (PC with PC card slot) E10A emulator PC card slot PC PC Card User system User ...

  • Renesas SH7600 Series - page 8

    4 1.2 Connecting the E10A Emulator with the User System To connect the E10A emulator (hereina fter referred t o as the emulator), the H-UDI p ort connector must be installed on the user system to connect t he user system interface cable. When designing the user system, refer t o the recommended circuit between the H-UDI port connector and the MCU. ...

  • Renesas SH7600 Series - page 9

    5 1.3 Installing the H-UDI Port Connector on the User System Table 1.3 show s the recommended H-UDI port connecto rs for the emul ator. Table 1.3 Recommended H-UDI Port Connectors Connector Type Number Manufacturer Specifications DX10M-36S Screw type 36-pin conne ctor D X10M-36SE, DX10G1M-36SE Hirose Electri c Co., Ltd. Lock-pin ty pe 14-pin conne ...

  • Renesas SH7600 Series - page 10

    6 Notes: H-UDI port connector (Pin 1 mark) (top view) Unit: mm 4.8 M2.6 x 0.45 9.0 0.3 3.9 H-UDI port connector (front view) 1. Input to or output from the user system. 2. The slash (/) means that the signal is active-low. 3. The emulator monitors the GND signal of the user system and detects whether or not the user system is connected. Pin No . Si ...

  • Renesas SH7600 Series - page 11

    7 Pin 1 mark Notes: 1. Input to or output from the user system. 2. The slash (/) means that the signal is active-low. 3. The emulator monitors the GND signal of the user system and detects whether the user system is connected or not. 25.0 23.0 6 x 2.54 = 15.24 (2.54) 0.45 Pin 1 Pin 8 Pin 7 Pin 14 Pin 1 mark H-UDI port connector (top view) H-UDI por ...

  • Renesas SH7600 Series - page 12

    8 1.5 Recommended Circuit between the H- UDI Port Connector and the MPU 1.5.1 Recommended Circuit ( 36-Pin Ty pe) Figure 1.4 s hows a recommen ded circuit between the H -UDI port c onnector (36 pins ) and the MPU. Notes: 1. Do not connect anything t o the N.C . pin of the H-UDI po rt connector . 2. The processing of the /ASEM D0 pin differs dependi ...

  • Renesas SH7600 Series - page 13

    9 1 AUDATA0 AUDATA2 AUDATA1 AUDATA3 TCK TMS AUDSYNC N.C. N.C. RESET TDI TDO TRST ASEBRKAK NC GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 2 4 6 8 12 10 14 16 18 20 22 24 26 28 30 32 34 36 AUDATA0 AUDATA2 AUDATA1 AUDATA3 TCK RESETP TMS TDO TDI TRST ASEBRKAK AUDCK AUDSYNC A ...

  • Renesas SH7600 Series - page 14

    10 1.5.2 Recommended Circuit ( 14-Pin Ty pe) Figure 1.5 shows a recomme nded circuit between the H-UDI port c onnector and the MPU. Notes: 1. Do not connect anythi ng to the N.C . pin of the H-UDI p ort connector. 2. The processing of the /ASEM D0 pin differs depending on w hether the emulat or is used or not. As the emulator d oes not control t hi ...

  • Renesas SH7600 Series - page 15

    11 1 TCK TMS RESET TDI TDO TRST ASEBRKAK GND GND GND GND GND GND 2 3 4 5 6 7 ASEMD0 8 9 11 10 12 13 14 TCK RESETP TMS TDO TDI TRST ASEBRKAK NC SH7630 VccQ (3.3 V) VccQ (3.3 V) H-UDI port connector (14-pin type) Reset signal 4.7 k Ω 4.7 k Ω 1 k Ω Figure 1.5 Recommended Circuit for Connection between the H-UDI Port Connector and MPU (14 - Pin T ...

  • Renesas SH7600 Series - page 16

    12 ...

  • Renesas SH7600 Series - page 17

    13 Section 2 Specifications of the SH7630 E10A Emulator’ s Software 2.1 Differences between the SH7630 and the Emulator • When the emu lato r system is initiated, it initializes th e g eneral reg ister s an d part of the control registers as s hown in table 2.1. The initial values of the actual SH7630 regis ters are undefined. Table 2.1 Regi st ...

  • Renesas SH7600 Series - page 18

    14 • Reset Signals The SH7630 res et signals are only valid duri ng emulation s tarted with cli cking the GO or STEP- type button. I f these signals are input from t he user system i n command input wait s tate, they are not sent t o the SH7630. Note: Do not break the user program when t he /RESETP and /WA IT signals are being low. A TIMEOUT erro ...

  • Renesas SH7600 Series - page 19

    15 • UBC When [User] is specified in th e [UBC mode] lis t box in the [ Configuration ] dialog box, the UBC can be used in the us er progra m. Do not use the UB C in the use r program as it is used by the E10A emul ator when [EML] i s specified in the [U BC mode] li st box in the [Co nfiguration] dialog box. • Loading Ses sions Information i n ...

  • Renesas SH7600 Series - page 20

    16 • Illegal Instru ctions If illegal instru ctio ns are executed by STEP-type command s, the emulato r cannot go to the next program count er. 2.2 Specific Functions for the SH7630 E10A Emulator The SH7630 E10A em ulator d oes not support the following function: • MMU-related funct ions (The S H7630 does not m ount the MMU.)  VPMAP-rela ted ...

  • Renesas SH7600 Series - page 21

    17 Table 2.4 Ty pes of Break Co ndit ions Break Conditi on Type Description Address bus condition (A ddress) Breaks when the SH7630 ad dress bu s value or th e program counter value matc hes the spe cifi ed val ue. Data bus c ondition (Dat a) Breaks when the SH7630 dat a bus va lue matches th e specified value. Byte, word, or longword can be specif ...

  • Renesas SH7600 Series - page 22

    18 Table 2.5 lists the combi nations of conditions that can be set under Break Condition 1, 2, 3. Table 2.5 Di alog Boxes for Setting B reak Condition s Type Dialog Box Address Bus Condition (Address) Data Bus Condition (Data) Bus State Condition (Bus Status) Count Condition (Count) Internal I/O Break [Break Condi tion 1] dialog bo x O O O O X [Bre ...

  • Renesas SH7600 Series - page 23

    19 AUD Trace Functions: This fun ction is operational wh en the AUD pin of the d evice is connected to the emulator. Table 2.8 shows th e AUD trace acq uisition mode that can be set in each trace function. Table 2.8 AUD Trace Acqu isitio n Mode Type Mode Description Continuou s trace occurs Realtime tr ace When the n ext branch oc curs while t he t ...

  • Renesas SH7600 Series - page 24

    20 To set the AUD trace acquisition mode, click the [Trace] window with the right m ouse button and select [Setting] from the pop-u p menu to display the [Acquis ition] dialog box. The AUD tr ace acquisition mode can be s et in the [AUD mode1] or [AUD mode2] group box in the [Tra ce mode] page of the [Acq uisition] dial og box. Figure 2.1 [Trace mo ...

  • Renesas SH7600 Series - page 25

    21 (a) Branch Trace Function The branch source and destinat ion addresses and thei r source l ines are displayed. Branch trace can be acquire d by selecting the [Branc h trace] check box in the [AUD fu nction] group box of the [Trace mode ] page. The branch type can be selected in the [AUD Branch trace] page. Figure 2.2 [AUD Branch trace] Page (b) ...

  • Renesas SH7600 Series - page 26

    22 Figure 2.3 [W indow trace] Page Note: Wh en the [L-bus] or [I-bus] r adio button is selected, the f o llowing bus cycles will be traced. L-bus: A bus cycl e generated by the CPU is acqui red. A bus cycle is also acquired when the cache has been hit. I-bus: A bus cycl e generated b y the CPU or DMA is acquired. A bus cycl e is not acquire d when ...

  • Renesas SH7600 Series - page 27

    23 (c) Software Trace Function Note: This functio n can be supported with SHC comp iler V7.0 and later. When a specific instruction is executed, the PC value at execution and the contents of one general register are acquire d by trace. Describe the Trace(x ) function (x is a va riable name) to be compiled a nd linked be forehand. For deta ils, refe ...

  • Renesas SH7600 Series - page 28

    24 Internal Trace Function: This function is activated by selecting the [Internal trace] radio button in the [Trace type] group box of the [T race mode] page. Se e figure 2.1, [Trace m ode] Page. The internal trace functions are als o activated by selecting each check bo x on the [Branch trace ] page. Notes: 1. If an interrupt is ge nerated at the ...

  • Renesas SH7600 Series - page 29

    25 6. When a BREAKP OINT is set to th e slot instructio n of a delayed branch in struction, the PC value becom es an illegal value. Accord ingly , do not set a BREAKPOI NT to the slot instructi on of a delayed branc h instructi on. 7. When a BREAKPOINT is set to the cacheable area, the cac he block containing t he BREAKPOINT addres s is filled imme ...

  • Renesas SH7600 Series - page 30

    26 2.2.7 Notes on Setting the UBC_MODE Command In the [Confi guration] wind ow, if [User] is set while t he [UBC mode] list box has been set, t he STEP-type comman ds that use B reak Condition 2 for imple mentation cannot be used. 2.2.8 Performance Measurement Function The SH7630 E10A em ulator s upports the perf ormance measurement f unction. 1. S ...

  • Renesas SH7600 Series - page 31

    27 Figure 2.4 [Perform ance Analys is] Dialog B ox  Measurement range One of the foll owing ranges c an be specified. This depends on the i tem selected fo r [Mode] in the [Performance Anal ysis] dialog box. 1. From the start t o the end of th e user program execut ion (When Normal B reak is selected for [Mo de]) 2. From the satisfactio n of the ...

  • Renesas SH7600 Series - page 32

    28 2. Step execution is n ot possible when Break condition 1->2 or Break con d itio n 2->1 is selected for the PERFOR MANCE_SET command or in [Mode] of the [Per formance Analysis ] dialog box. 3. When Break con dition 1->2 or Break conditio n 2->1 is selected in [ Mo de] of the [Performance Anal ysis] dialog box, specify one or more ite ...

  • Renesas SH7600 Series - page 33

    29 Table 2.10 Measurement Item Selected Name Option Disabled None Elapsed tim e AC Number of exe cution stat es VS Branch instru ction count s BT Number of e xecution instr uctions I DSP-instructi on execution counts DI (Devices incorporating t he DSP funct ion can only be mea sured.) Instructi on/d ata con fli ct cycle MAC Other confl ict cycle s ...

  • Renesas SH7600 Series - page 34

    30 Table 2.10 Measurement Item (cont) Selected Name Option Cacheable area instru ction acces s cycle CIC Cacheabl e area d ata access cycle CDC Access counts othe r than instr uction/data NAM Non-cacheable are a access count s NCN Non-cache able are a instructi on acce ss counts NCIN Non-cacheable ar ea d ata access counts NCDN Cacheable area ac ce ...

  • Renesas SH7600 Series - page 35

    SuperH TM Family E10A Emulator Additional Document for User's Manual Specific Guide for the SH7630 E10A Emulator Publication Date: Rev.1.00, July 3, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd.  2003 Renesas T ...

  • Renesas SH7600 Series - page 36

    SuperH  Family E10A Emulator Addition al Document for User’ s Manual REJ10B0015-0100H ...

メーカー Renesas カテゴリー Network Card

Renesas SH7600 Seriesのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SH7600 Seriesの取扱説明書
- Renesasの製品カード
- パンフレット
- またはRenesas SH7600 Seriesの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Renesas SH7600 Seriesの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Renesas SH7600 Seriesの取り付け説明書、サービスマニュアル、簡易説明書、またはRenesas SH7600 Seriesのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Renesas SH7600 Seriesの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Renesas SH7600 Seriesデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRenesas SH7600 Seriesを使用するのを助ける技術的文書のことです。説明書は通常、全てのRenesas SH7600 Seriesユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Renesasの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Renesas SH7600 Seriesの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRenesas SH7600 Seriesの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Renesas SH7600 Seriesに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Renesas SH7600 Seriesデバイスの基本機能を使うにあたってのヒント。 Renesas SH7600 Seriesのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Renesas SH7600 Seriesに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRenesas SH7600 Seriesのメーカー/サービスへの連絡先に関する情報。

Renesas SH7600 Seriesについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRenesas SH7600 Seriesの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRenesas SH7600 Seriesで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)