Miller Electric 188 036Gの取扱説明書

28ページ 1.01 mb
ダウンロード

ページに移動 of 28

Summary
  • Miller Electric 188 036G - page 1

    Visit our website at www.M il ler Weld s.c om OM -2219 188 036G October 1999 Processes Processes Descrip tio n Air Plasma Cutting and Gouging Air Plasma Cutter Spectrum L ynx R ...

  • Miller Electric 188 036G - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .MillerW eld ...

  • Miller Electric 188 036G - page 3

    T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Plasma Arc Cutting Hazards 1 . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric 188 036G - page 4

    ...

  • Miller Electric 188 036G - page 5

    OM-2219 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING pom _nd_9/98 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means W arning! Watch ...

  • Miller Electric 188 036G - page 6

    OM-2219 Page 2 D On inverter power sources, failed parts can ex- plode or cause other parts to explode when power is applied. Always wear a face shield and long sleeves when servicing inverters. EXPLODING P ARTS can injure. Sparks and hot metal blow out from the cutting arc. Chipping and grinding cause flying metal. FL YING SP ARKS can cause injury ...

  • Miller Electric 188 036G - page 7

    OM-2219 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance HOT P ARTS can cause severe burns. D Do not touch hot parts bare handed. D Allow cooling period before working on torch. MOVING P ARTS can cause injury . D Keep away from moving parts such as fans. D Keep all doors, panels, covers, and guards closed and securely in ...

  • Miller Electric 188 036G - page 8

    OM-2219 Page 4 1-4. Principal Safety Standards Safety in Welding and Cutting , ANSI Standard Z49.1, from American W elding Society , 550 N.W . LeJeune Rd, Miami FL 33126 Safety and Health Standards , OSHA 29 CFR 1910, from Superinten- dent o f Documents, U.S. Government Printing Of fice, Washington, D.C. 20402. Recommended Practices for Plasma Arc ...

  • Miller Electric 188 036G - page 9

    OM-2219 Page 5 SECTION 1 – CONSIGNES DE S É CURIT É – LIRE A V ANT UTILISA TION pom_nd_fre_5/97 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives. Y Identifie un message de s é curit é particuli ...

  • Miller Electric 188 036G - page 10

    OM-2219 Page 6 D N ’ approchez pas le tube du chalumeau et l ’ arc pilote lorsque la g â chette est enfonc é e. D Le c â ble de masse doit ê tre pinc é correctement sur la pi è ce à couper , m é tal contre m é tal (et non de telle sorte qu ’ il puisse se d é tacher), ou sur la table de travail le plus pr è s possible de la ligne de ...

  • Miller Electric 188 036G - page 11

    OM-2219 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance DES PIECES CHAUDES peuvent pro- voquer des br û lures graves. D Ne pas toucher des parties chaudes à mains nues. D Laisser refroidir avant d ’ intervenir sur la torche. DES ORGANES MOBILES peuvent provoquer des blessures. D S ...

  • Miller Electric 188 036G - page 12

    OM-2219 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American W el- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Of fice, Washington, D.C. 20402. Recommended Safe Practice for th ...

  • Miller Electric 188 036G - page 13

    OM-2219 Page 9 SECTION 2 – INST ALLA TION 2-1. Specifications Rated Cutting Maximum Open- T ype of Output Plasma Gas Rated Output Rated Cutting Capacity Maximum Open- Circuit V oltage DC Direct Current, Straight 50 A @ 1 10 V olts DC, 0.7 in (16 mm) Direct Current, Straight Polarity (DCEN) Air Or Nitrogen Only 50 A @ 1 10 V olts DC, 50% Duty Cycl ...

  • Miller Electric 188 036G - page 14

    OM-2219 Page 10 2-4. Selecting A Location loc_2 3/96 - ST-801 976 1 Lifting Handles Use handles to lift unit. 2 Hand Cart Use cart or similar device to move unit. Y Special installation may be required where gasoline or volatile liquids are present – see NEC Article 51 1 or CEC Section 20 . Dimensions And W eight 1 2 Y Do not move or operate unit ...

  • Miller Electric 188 036G - page 15

    OM-2219 Page 1 1 2-5. Connecting W ork Clamp And Gas/Air Supply Ref. 801 977-A 1 Work Clamp 2 W orkpiece W ork clamp cable is attached to front o f unit. Connect work clamp to a clean, paint-free location on work- piece, as close to cutting area as possible. . Use only clean, dry air with 90 to 150 psi pressure. 3 Gas/Air Inlet Opening 4 Hose 5 T e ...

  • Miller Electric 188 036G - page 16

    OM-2219 Page 12 SECTION 3 – OPERA TION If the welding generator includes a fine adjust control, be sure to set the control to maximum for full output control capacity . When using the Lynx, auxiliary power output is not available from the 120 or 240 V AC receptacles on the welding generator . NOTE 3-1. Controls Ref. ST -189 734 / Ref. 801 977 – ...

  • Miller Electric 188 036G - page 17

    OM-2219 Page 13 1 Output Control 2 Power Switch Place controls as indicated above. Only gas/ air circuit is activated when the Power switch is turned On with Output Control in Gas/Air Set position. 3 Gas/Air Pressure Adjustment Knob Pull knob and turn to adjust pressure. Push knob in to lock setting. Select desired cutting output with Output Contro ...

  • Miller Electric 188 036G - page 18

    OM-2219 Page 14 3-3. Sequence Of Operation Put On Personal Safety Equipment After cutting arc starts, slowly start moving torch across metal. Adjust torch speed so sparks go thru metal and out bottom of cut. Pause briefly at end of cut before releasing trigger . Install & Connect Equipment EXAMPLE Of Cutting Operation ST-801 400-A Press trigger ...

  • Miller Electric 188 036G - page 19

    OM-2219 Page 15 SECTION 4 – MAINTENANCE & TROUBLESHOOTING 4-1. Routine Maintenance Y Disconnect power before maintaining. . Maintain more often during severe conditions. Each Use Check T orch T ip, Electrode, And Shield Cup Check Gas/Air Pressure Every Week Check Shield Cup Shutdown System 3 Months Service A i r Filter/Regulator Assembly Filt ...

  • Miller Electric 188 036G - page 20

    OM-2219 Page 16 4-2. Ground Fault Circuit Interrupter (GFCI) Ref. 801 977-A / Ref. 802 180-A 1 Ground Fault Circuit Interrupter GFCI 2 Spring-Loaded Door (Shown Open) GFCI provides ground fault protec- tion for the input power connection. If a ground fault is detected, GFCI RESET button pops out and the unit will not function. Press button to reset ...

  • Miller Electric 188 036G - page 21

    OM-2219 Page 17 4-3. T rouble Lights 1 Pressure Light Lights if gas/air pressure is below 40 PSI (276 kPa). Tur n power Of f, and check for prop- er gas/air pressure (see Section 3-2). 2 Cup Light Lights if shield cup is loose. T urn power Of f, and check shield cup connection (see torch Owner ’ s Manual). Power must be reset whenever the cup shu ...

  • Miller Electric 188 036G - page 22

    OM-2219 Page 18 T rouble Remedy No cutting output; Power light of f; T rouble lights of f; Ready light o f f; fan mo- tor FM does not run. Place Power switch in On position. Reset welding generator circuit breaker CB1 and/or CB2. Check power plug connection at welding generator . Have Factory Authorized Service Agent check power switch S1, transfor ...

  • Miller Electric 188 036G - page 23

    OM-2219 Page 19 SECTION 5 – ELECTRICAL DIAGRAM 193 622 Figure 5-1. Circuit Diagram ...

  • Miller Electric 188 036G - page 24

    OM-2219 Page 20 SECTION 6 – P ARTS LIST . Hardware is common and not available unless listed. 802 180-C 1 2 3 4 6 7 8 9 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 48 49 50 5 47 53 54 51 51 52 57 55 55 56 19 Figure 6-1. Complete Assembly ...

  • Miller Electric 188 036G - page 25

    OM-2219 Page 21 Description Part No. Dia. Mkgs. Item No. Figure 6-1. Complete Assembly Quantity 1 187 782 WRAPPER 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 126 416 HANDLE, molded 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric 188 036G - page 26

    OM-2219 Page 22 Description Part No. Dia. Mkgs. Item No. Figure 6-1. Complete Assembly (continued) Quantity 51 138 442 LABEL, caution falling equipment 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 178 739 FITTING, plastic straight fem 1/8 NPT 1 . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric 188 036G - page 27

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y ou r distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise ...

  • Miller Electric 188 036G - page 28

    PRINTED IN USA  2000 Miller Electric Mfg. Co. 6/00 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Company 1635 West Spencer St reet Applet on, WI 54914 USA International He adquarters – USA USA Phone: 920-735-4505 Aut o-At t ended USA & C anada FAX: 920-735-4134 Int ernati onal F A X : 920-735-4125 European H eadqua rters – United ...

メーカー Miller Electric カテゴリー Welder

Miller Electric 188 036Gのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 188 036Gの取扱説明書
- Miller Electricの製品カード
- パンフレット
- またはMiller Electric 188 036Gの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miller Electric 188 036Gの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miller Electric 188 036Gの取り付け説明書、サービスマニュアル、簡易説明書、またはMiller Electric 188 036Gのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miller Electric 188 036Gの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Miller Electric 188 036Gデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiller Electric 188 036Gを使用するのを助ける技術的文書のことです。説明書は通常、全てのMiller Electric 188 036Gユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Miller Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miller Electric 188 036Gの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiller Electric 188 036Gの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miller Electric 188 036Gに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miller Electric 188 036Gデバイスの基本機能を使うにあたってのヒント。 Miller Electric 188 036Gのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miller Electric 188 036Gに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiller Electric 188 036Gのメーカー/サービスへの連絡先に関する情報。

Miller Electric 188 036Gについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiller Electric 188 036Gの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiller Electric 188 036Gで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)