  • Electro-Voice R300 - page 1

    R 300 UH F W i re l e ss MicropHon e U SER GUID E EZ sync Clear Scan Electro-V oice R 300 SET SYNC ...

  • Electro-Voice R300 - page 2

    2 ...

  • Electro-Voice R300 - page 3

    3 TA B L E o F co nte nt s 1. Quick System Setup  •Receiver ................................................................................................................. 4  •T ransmitter ............................................................................................................. 5  •SystemsOperation . ...

  • Electro-Voice R300 - page 4

    4 0 1 QU ICK S ETU P: r ec eive r 1.Donotconnectthereceivertoanyotherequipmentyet! 2.ConnectthetwoAntennastothereceiver . 3.Installthebladesintothepowersupply,plugitintothebac kofthereceiver , andintoanoutlet. 4.PressthePOWE Rs ...

  • Electro-Voice R300 - page 5

    5 QU ICK S E TU P: tran sM itte r 1.W iththePowerswitc honthetransmitterO FF ,installtwofreshAAbatteriesintothetransmitter . 2.PressthetransmitterPowerSwitc huntilthedisplaycomeson. 3.HoldthetransmitterwiththeE ZsyncP ortfacingthereceiver, ...

  • Electro-Voice R300 - page 6

    6 QU ICK S E TU P: s y s teMs opera t ion 1.Setthemixer/ampgain. 2. T alkorsingintothemicrophoneorplaytheguitaratanormalvolume.Y ou shouldhearaudiocomingoutofthesystem. 3. Y oumayhavetoadjustthegain(viathecontrolnextto ...

  • Electro-Voice R300 - page 7

    7 SYNC R 300 EZ sync Clear SET EZ sync Clear Scan Electro- Vo ice R 300 ANTENNA B ANTENNA A 12V .500mA MIN MAX VOLUME LEVEL -10dB 0dB BALANCED OUT UNBALANCED OUT DET AILE D coMpone n t de scri p tions 2.1 | R300 Receiver R ECEIVE R CONTROLS, CON N ECT OR S 1.PowerON /OFF 2.S YNCDat aT ransferButton 3.InfraredE ZsyncW indo ...

  • Electro-Voice R300 - page 8

    8 DET AILE D coMpone n t de scri p tions 2.1 | Receiver Setup & Operation 1. Placethereceiverandantennaswherethereisaclearlineofsighttotheareawherethetransmitter willbeused.Rotatetheantennastoseparatethemby9 0degrees. 2. Install the appropriate power ...

  • Electro-Voice R300 - page 9

    9 e.PresstheS YNCbuttononthereceivertotransferthechannelinformation. f.ThereceiverwilldisplayS YN Cuntilthedataistransferred,thenreturntothemainscreen. g.Thetransmitterdisplayscreenwillnowshowthenewc hannelandfrequency . h. ...

  • Electro-Voice R300 - page 10

    10 DET AILE D coMpone n t de scri p tions 4. ClearScan: Thisfeatureautomatestheprocessofndingaclearchannel.   a. T oscanfortheclearestc hannelinagroup,pressandhold untilCLEAR S C AN appearsinthedisplay ,thenreleasethebutton.   b.W he ...

  • Electro-Voice R300 - page 11

    11 7 .  W iththetransmitteron,speakintothemicrophoneorplaytheguitar.T urnupthelevelonthemixer oramplieruntilyouareabletohearthedesiredsignal.Ifnoaudioispresent,repeatsetupand refertothetroubleshootingsection. Not ...

  • Electro-Voice R300 - page 12

    12 DET AILE D coMpone n t de scri p tions 9. Change Lock-Out Thisfeaturecanbeusefulwhenthereceiverisinalocationwhere unauthorizedpersonnelhaveaccesstothereceiver .W iththeL OC KON,thechannelcannot bechangedandthewordL OC Kisdisplayedwhenthe? ...

  • Electro-Voice R300 - page 13

    13 1 0. Squelc h Adjustment –Thesquelc hsettingcanbeusedtomaximizerangeorimmunitytonoise.   a.T urnthetransmitteroff.   b.PressandholdtheSETbuttonuntilD ISP L Yshowsinthedisplay .   c.Press twotimestodisplaySQE L C H. ? ...

  • Electro-Voice R300 - page 14

    14 DET AILE D coMpone n t de scri p tions 2.1.2 | Receiver Main Operating Screen Display: 1. R FSignalMeter 2. AudioMeter 3. LockIndicator 4. NoSignalIndicator 5. ChannelNumber(0 1to32)orFrequency 6. SquelchSetting 7 . AntennaDiversityStatusAorBantenna Controls: 1. ...

  • Electro-Voice R300 - page 15

    15 2.2 | Handheld T ransmitter HT -300CO NTROLS,CO NN ECT O R SANDI N DICA T O RS 1. MicrophoneElement 2. B ac klitL C DDisplay   a.Channel   b.Frequency   c.BatteryLevel   d.MuteIndicator 3. E ZSyncInfraredPort 4. B atteryCover–Screwtype. 5. B atte ...

  • Electro-Voice R300 - page 16

    16 DET AILE D coMpone n t de scri p tions 2.2 | Handheld T ransmitter Setup & Operation 1. Insert Batteries.   a.Removethebatterycompartmentcoverbyunscrewingitcompletely.   b.  InserttwoAAbatteriesasshown,slidingoneupintothehousingtomakeroomfor  the? ...

  • Electro-Voice R300 - page 17

    17 5. Mute Function –pressandholdon/offbuttonfor2secondsuntilM UTEappearsintheL CD DisplaybetweentheChannelandFrequency .Thesoundisthenmuted.Repeattoturnmuteoff. 2.3 | Bodypack T ransmitter B P-300CO NTROLS,CO NN E C T O RSAN DI N DICA T O ...

  • Electro-Voice R300 - page 18

    18 DET AILE D coMpone n t de scri p tions 2.3 | Bodypack T ransmitter continued 5. L CDDisplay   a.Channel   b.Frequency   c.BatteryLevel   d.MuteIndicator 6. E Zsyncinfraredwindow 7 . BatteryCompartmentLatch–pushdownlatchandslidecoverasshown. 8. T wo? ...

  • Electro-Voice R300 - page 19

    19 2.3.1 | Bodypack T ransmitter Setup & Operation 1. Insert Batteries   a. Openthebatterycompartmentbypressinginonthelatchandslidingthedoordown.   b.InserttwoAAbatterieswith+and–asindicated.   c.Closethebatterydoorbypushing ...

  • Electro-Voice R300 - page 20

    20 GUID EL INES A N D  R ECOMM EN D A TIONS  F orBestPerformance Compatibility Thetransmitterandreceivermustbeofthesamefrequencybandandsettothesamechannelinorder toworktogether .TheR300isavailableinthreefrequencybands,A,BandE(Europe? ...

  • Electro-Voice R300 - page 21

    21 adverselyaffecttheperformanceofyourwirelesssystem.Itisalwaysbesttoplacethereceiverasfar awayaspossiblefromthesedevicestominimizepotentialproblems. AnalogandDigitalT elevisionstationscanalsointerferewithyourwirelesssystem.TheR30 ...

  • Electro-Voice R300 - page 22

    22 TROU B L E SHOO T I NG GUI DE 0 4 Problem P ossible Causes Solutions Noaudioandnodisplayon thereceiver Receiverisoff Makesurethatthepowersupplyisproperly connectedandtheon/offbuttonisintheonposition NoaudioandnoR F signalindicatoronthe ...

  • Electro-Voice R300 - page 23

    23 Problem P ossible Causes Solutions Interference Anotherwirelessproductintheareais onthesamefrequencyorthesignals aremixing UseClearScantochangetheoperatingfrequency . Ifproblemspersist,callEVat800-3 92-3497for coordinationhelp Receiveristooclose ...

  • Electro-Voice R300 - page 24

    24 S PECI F IC A TION S R300 Receiver ReceiverT ype SynthesizedPLL FrequencyRange(R F) ABand618–63 4MHz  BBand67 8–6 94M Hz  EBand85 0–865M Hz NumberofChannels 32 Modulation +/-40kHz Diversity Antenna R FSensitivity <1.0μVfor12dBSI NAD Image ...

  • Electro-Voice R300 - page 25

    25 Audio Parameters FrequencyResponse 80–18kHz+/-2dB BalancedOutput 20dBV(max@4 0kHzdeviation) UnbalancedOutput Adjustable8mVto0. 755VR MS Distortion <1.0%,0.4%typical(ref1kHz,40kHzdeviation) Signal-to-NoiseRatio >1 00dBAW eighted DynamicRange >9 ...

  • Electro-Voice R300 - page 26

    26 CE RTI FICA TION S (Dependingonfrequencyselectedandcountryofoperation) R300receiver,HT -3 00andBP-3 00transmitters:CertiedtoET S IEN3 00422-2andET SIE N3 0 148 9-9, ConformstoEuropeanUniondirectives,eligibletobearCEmarkingaspertheR&a ...

  • Electro-Voice R300 - page 27

    27 F ACTORY  SE RV ICE Factory Service (North America) Iffactoryserviceisrequired,shiptheunitprepaidinitsoriginalcartonto: EVAudioService c/oBoschSecuritySystems,Inc. 86 0 1EastCornhuskerHighway Lincoln,N E68507 -97 02U.S.A. T el:402-467 -5321or8 00-553-5992 Fax: ...

  • Electro-Voice R300 - page 28

    28 A C C ESS O RIES AN DP A RT S 0 8 Accessories and Parts Model # Order # R300-LSystemUniLapel U LM18 F .0 1U.168.8 03 R300-ESystemHeadwornMicrophone H M3 F .0 1U.168.8 04 W indscreenforU LM18 WS-18 F .01U.168.802 W indscreenforH M3 WS-H3 F .01U.1 7 0. 77 8 BeltclipforB P-300 B C-300 F .01U.168. 7 97 Guita ...

  • Electro-Voice R300 - page 29

    29 A CC ESS O RIES A N DP ARTS APPEN D IX A  CO MP A T IBL E  CH A NNEL  GROUP S (UseonlychannelswithinthesamegroupwhenusingmorethantwoR300unitsinoneroom. Ifyouneedadditionalhelpcall1-800-3 92-3497(USandCanadaonly). 0 9 US /E URO Band A 6 1 8-63 4 MHz Gr ...

  • Electro-Voice R300 - page 30

    30 APPENDIX A  CO MP A T IBL E  CH A NNEL  GRO UPS 0 9 US /E URO Band B 678-694 M Hz Group 1 Group 2 Group 3 Group 4 Channel Freq Channel Fre q Channel Freq Channel Freq 1 6 78.500 9 67 8.9 00 17 6 79.300 25 679 . 70 0 2 682. 700 10 680.1 00 18 68 0.500 26 68 0.900 3 684.4 00 11 681.500 19 6 81.900 27 682.3 00 4 688.3 00 12 683.1 00 20 6 8 ...

  • Electro-Voice R300 - page 31

    31 APPENDIX A  CO MP A T IBL E  CH A NNEL  GRO UPS Euro Band E 850-8 65 M Hz Group 1 Group 2 Group 3 Group 4 Channel Freq Channel Fre q Channel Freq Channel Freq 1 850.4 00 9 850.8 00 17 851.200 25 850.000 2 851.600 10 852.000 18 852.4 00 26 854.200 3 853.000 11 853.400 19 853.8 00 27 855.900 4 854.600 12 855.000 20 855.4 00 28 859.800 5 8 ...

  • Electro-Voice R300 - page 32

    32 Americas: HeadquartersAmericas BoschSecuritySystems,Inc. 12000PortlandA veSouth, Burnsville,M N5533 7 ,USA USA–Ph:1-8 00-392-34 9 7 Fax:1-800-955-6 831 Canada: Ph:1-86 6-505-5551 Fax:1-86 6-336-84 6 7 Latin America: Ph:1-952-887 -5532 Fax:1-952- 736-4212 Europe, Africa & Middle-East: Headquar ...

メーカー Electro-Voice カテゴリー Headphones

Electro-Voice R300のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- R300の取扱説明書
- Electro-Voiceの製品カード
- パンフレット
- またはElectro-Voice R300の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Electro-Voice R300の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Electro-Voice R300の取り付け説明書、サービスマニュアル、簡易説明書、またはElectro-Voice R300のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Electro-Voice R300の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Electro-Voice R300デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがElectro-Voice R300を使用するのを助ける技術的文書のことです。説明書は通常、全てのElectro-Voice R300ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Electro-Voiceの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Electro-Voice R300の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははElectro-Voice R300の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Electro-Voice R300に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Electro-Voice R300デバイスの基本機能を使うにあたってのヒント。 Electro-Voice R300のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Electro-Voice R300に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるElectro-Voice R300のメーカー/サービスへの連絡先に関する情報。

Electro-Voice R300についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもElectro-Voice R300の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがElectro-Voice R300で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)