    H-IM-CU August 2008 P ar t No . 25008101 H-IM-CU-0808 | V ersion 000 C ondensing Units Installation and Opera tions Manual T able of C ontents General Safety Information...............................................................................2 Inspection ......................................................................................... ...

  • Heatcraft Refrigeration Products H-IM-CU - page 2

    2 General Safety Information Installation and maintenance to be performed only by qualied personnel who are familiar with this type of equipment. Some units are pressurized with dry air or iner t gas. All units must be evacuated befor e charging the system with r efrigerant. 1. 2. W ARNING: Refr igerant can be harmful if it is inhaled. Refrigera ...

  • Heatcraft Refrigeration Products H-IM-CU - page 3

    3 © 2008 Heatcraft Refrigeration Products LL C The most important consideration which must be taken into account when deciding upon the location of air-cooled equipment is the provision for a supply of ambient air to the condenser , and removal of heated air fr om the condensing unit or remote c ondenser area. Where this essential requirement is n ...

  • Heatcraft Refrigeration Products H-IM-CU - page 4

    4 Requirements for Remot e and Wa ter Cooled Condensing Units General Installation The indoor compressor units ar e designed to be used with a remote condenser . T he water cooled units are similar , except that they have an integral wat er cooled condenser . Inlet and outlet water connections are to be made in the eld. On units having a compr e ...

  • Heatcraft Refrigeration Products H-IM-CU - page 5

    5 Figur e 3. Spring Mount Figur e 5. Spring Mount Figur e 4. Solid Mount for Mobile or Deep Sump Application Condensing Unit Rigging and Mounting Rigging holes are provided on all units . Caution should be exer cised when moving these units. T o prevent damage to the unit housing during rigging, cables or chains used must be held apart by spacer ba ...

  • Heatcraft Refrigeration Products H-IM-CU - page 6

    6 CAUTION: Under no circumstance should all condenser motors be allo wed to cycle o on one control . At least one motor shall be wired t o operate at all times. Under most circumstances, the c ondenser motor nearest the inlet header should remain on whenev er the compressor is operating . CAUTION: F ans closest to the headers should not be c ycl ...

  • Heatcraft Refrigeration Products H-IM-CU - page 7

    7 Refrigeration Oils* With the changes that hav e taken place in our industry due to the CFC issue, we hav e reevaluated our lubricants t o ensure compatibility with the new HFC refrigerants and HCFC interim blends o ered by several chemical producers. A s a secondary criteria, it is also desirable that any new lubricant be compatible with the t ...

  • Heatcraft Refrigeration Products H-IM-CU - page 8

    8 Figur e 9. Example of Pipe Support Figur e 10. Condensing Unit / C ompressor to W all Suppor t Suction Lines Horizontal suction lines should slope away from the evapor ator towar d the compressor at the rat e of 1/4 inch per 10 feet for good oil r eturn. W hen multiple evaporators are c onnected in series using a common suction line, the branch s ...

  • Heatcraft Refrigeration Products H-IM-CU - page 9

    9 Liquid Lines Liquid lines should be sized for a minimum pressur e drop to prev ent “ashing” . Flashing in the liquid lines would creat e additional pressure drop and poor expansion valve operation. If a system r equires long liquid lines from the receiv er to the evaporator or if the liquid has to rise v ertically upward an y distance, the ...

  • Heatcraft Refrigeration Products H-IM-CU - page 10

    10 Pipe size example: Given: -10°F Fr eezer with one system having (2) ev aporators • One condensing unit rated at 24,000 B TUH’ s @ -20°F SST R404A refrigerant. • T wo evaporators each rated at 12,000 BTUH ’ s @ 10°F TD . • 100 feet of actual line run between condensing unit to rst evaporat or and 20 feet of actual line run between ...

  • Heatcraft Refrigeration Products H-IM-CU - page 11

    11 T able 4. Pressure L oss of Liquid Refrigerants in Liquid Line Risers (Expressed in Pr essure Drop , PSIG, and Subcooling Loss, ˚F) Refrigerant Liquid Line Rise in Feet 10' 15' 20' 25' 30' 40' 50' 75' 100' PSIG ˚F PSIG ˚F PSIG ˚F PSIG ˚F PSIG ˚F PSIG ˚F PSIG ˚F PSIG ˚F PSIG ˚F R22 4.8 1.6 7. ...

  • Heatcraft Refrigeration Products H-IM-CU - page 12

    12 T able 7. Recommended Line Sizes for R-22 * Capacity BTUH Suction Line Size Liquid Line Size Suction T emperature Receiver to Expansion V alve Equivalent Lengths +40˚F Equivalent Lengths +20˚F Equivalent Lengths +10˚F Equivalent Lengths 0˚F Equivalent Lengths -10˚F Equivalent Lengths -20˚F Equivalent Lengths 25' 50' 100' 150 ...

  • Heatcraft Refrigeration Products H-IM-CU - page 13

    13 T able 8. Recommended Line Sizes f or R-404A and R507* Capacity BTUH Suction Line Size Liquid Line Size Suction T emperature Receiver to Expansion V alve Equivalent Lengths +20˚F Equivalent L engths +10˚F Equivalent L engths -10˚F Equivalent L engths -20˚F Equivalent L engths -30˚F Equivalent L engths -40˚F Equivalent L engths 25' 50& ...

  • Heatcraft Refrigeration Products H-IM-CU - page 14

    14 Evacua tion and Leak Detection Due to the smaller molecule size of HFC’ s, they will tend to leak more r eadily than CFC’ s. Consequently , it is of the utmost impor tance that proper system evacuation and leak detection procedures be emplo yed. Copeland recommends a minimum evacua tion to 500 microns. In addition, a vacuum decay test is str ...

  • Heatcraft Refrigeration Products H-IM-CU - page 15

    15 Check Out and Start Up After the installation has been completed, the f ollowing points should be cover ed before the syst em is placed in operation: Check all electrical and refrigerant connections. Be sure they are all tight. Observe compressor oil level befor e start-up. The oil level should be at or slightly abov e the 1/4 level of the sight ...

  • Heatcraft Refrigeration Products H-IM-CU - page 16

    16 Sy stem Balancing - Compr essor Superheat IMPORT ANT: In order to obtain the maximum capacity from a system, and to ensur e trouble-free operation, it is necessary to balance each and every system. This is extremely important with any refrigeration system. The critical value which must be checked is suction superheat. Suction superheat should be ...

  • Heatcraft Refrigeration Products H-IM-CU - page 17

    17 Electric Defrost T roubleshooting The electric defrost units are relativ ely simple and trouble-free in operation: Timer If the system does not go through its proper sequence , check timer operation through a defrost cycle . Check for loose wires or terminals . Before replacing timer , check other components. Operation of P aragon T imer T o set ...

  • Heatcraft Refrigeration Products H-IM-CU - page 18

    18 T able 10. System T roubleshooting Chart PROBLEM POSSIBLE CA USES POSSIBLE C ORREC TIVE STEPS Compressor will not run 1. Main switch open. 2. F use blown. 3. Thermal ov erloads tripped. 4. Defective con tactor or coil. 5. Sy stem shut down by safety devices . 6. No cooling r equired. 7. Liquid line solenoid will not open. 8. Motor electrical tro ...

  • Heatcraft Refrigeration Products H-IM-CU - page 19

    19 Air-Cooled C ondensing Units Quarterly 1) Visually inspect unit • Look for sig ns of oil stains on interconnection piping and condenser coil. P ay close attention t o areas around solder joints , building penetrations and pipe clamps. Check an y suspect areas with an electronic leak detector . Repair any leaks found and add refrigerant as need ...

  • Heatcraft Refrigeration Products H-IM-CU - page 20

    20 Diagram 3. T ypical W iring Diagram for Single Evapora tor with and without Defrost Timer Diagram 4. T ypical W iring Diagram for Single Evapora tor with Defrost Timer Only ...

  • Heatcraft Refrigeration Products H-IM-CU - page 21

    21 Diagram 5. T ypical W iring Diagram for Multiple Evapora tors with Defrost Timer Only Diagram 6. T ypical W iring Diagram for Single Evapora tor / Single Phase Defrost and E vaporat or F an Contactors ...

  • Heatcraft Refrigeration Products H-IM-CU - page 22

    22 Diagram 7. T ypical W iring Diagram for Single Evapora tor Defrost and E vaporat or F an Contactors Diagram 8. T ypical W iring Diagram for Multiple Evapora tors with Ev aporator F an Contactors/without Heat er Limit Defrost ...

  • Heatcraft Refrigeration Products H-IM-CU - page 23

    23 Diagram 10. T ypical W iring Diagram for Multiple Evapora tors Defrost and E vaporat or F an Contactors with Unit Cooler Holdout Rela y Diagram 9. T ypical W iring Diagram for Multiple Evapora tors with Heater Limit Defr ost and Evapor ator F an Contactors ...

  • Heatcraft Refrigeration Products H-IM-CU - page 24

    Since product improv ement is a continuing eort, we reserve the right to make changes in specications without notice. C L I M A T E C O N T R O L Commercial Refrigeration Parts The name behind the brands you trust. ™ H-IM-CU-0808 Commercial Refrigeration Parts Replacement P arts by InterLink™ Comercial Refrigeration Parts is your link t o ...

メーカー Heatcraft Refrigeration Products カテゴリー Humidifier

Heatcraft Refrigeration Products H-IM-CUのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- H-IM-CUの取扱説明書
- Heatcraft Refrigeration Productsの製品カード
- パンフレット
- またはHeatcraft Refrigeration Products H-IM-CUの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Heatcraft Refrigeration Products H-IM-CUの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Heatcraft Refrigeration Products H-IM-CUの取り付け説明書、サービスマニュアル、簡易説明書、またはHeatcraft Refrigeration Products H-IM-CUのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Heatcraft Refrigeration Products H-IM-CUの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Heatcraft Refrigeration Products H-IM-CUデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHeatcraft Refrigeration Products H-IM-CUを使用するのを助ける技術的文書のことです。説明書は通常、全てのHeatcraft Refrigeration Products H-IM-CUユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Heatcraft Refrigeration Productsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Heatcraft Refrigeration Products H-IM-CUの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHeatcraft Refrigeration Products H-IM-CUの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Heatcraft Refrigeration Products H-IM-CUに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Heatcraft Refrigeration Products H-IM-CUデバイスの基本機能を使うにあたってのヒント。 Heatcraft Refrigeration Products H-IM-CUのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Heatcraft Refrigeration Products H-IM-CUに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHeatcraft Refrigeration Products H-IM-CUのメーカー/サービスへの連絡先に関する情報。

Heatcraft Refrigeration Products H-IM-CUについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHeatcraft Refrigeration Products H-IM-CUの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHeatcraft Refrigeration Products H-IM-CUで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)