Heat Controller BHD-301-Cの取扱説明書

27ページ 4.09 mb
ダウンロード

ページに移動 of 27

Summary
  • Heat Controller BHD-301-C - page 1

    Dehumidifier Service Manual CAUTION -Before servicing the unit, read the "safety precautions" in this manual. -Only for authorized service personnel. HEA T CONTROLLER, INC. MODELS: BHD-301- C BHD-501- B BHD-651- C ...

  • Heat Controller BHD-301-C - page 2

    —2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ...........................................................................................................................3 1.2 FEATURES AND DIMENSIONS ................................................................................................................3 1.2.1 FEATURES ........................ ...

  • Heat Controller BHD-301-C - page 3

    —3— 1. PREF A CE This Service Manual provides various service information, including the mechanical and electrical parts. This dehumidifier was manufactured and assembled under the strict quality control procedures. The refrigerant is charged at the factory. Be sure to read the safety precaution prior to servicing the unit. 1.1 SAFETY PRECA UTI ...

  • Heat Controller BHD-301-C - page 4

    —4— 1.3 SPECIFICA TIONS *NOTE: Specifications are subject to minor change without notice for further improvement. CAPACITY(Pints/24hrs) 30 50 65 POWER SUPPLY(Phase,V,Hz) 1Ø, 115V,60Hz INPUT(W) 560 560 800 RUNNING CURRENT(A) 5.1 5.4 7.6 ENERGY FACTOR(L/kw.h) 1.05 1.75 1.60 REFRIGERANT R22 REFRIGERANT CHARGE, oz(g ) 5.29 (1 5 0 ) 9.17(260 ) 8.64 ...

  • Heat Controller BHD-301-C - page 5

    — 5 — 1 2 3 4 5 6 7 8 9 Off Max High Low Fan Speed Humidity Control Auto Shut-Off Humidity Control • When y ou first use the dehumidifier , tur n the humidity control to 5 or 6. If you still ha ve moisture , turn the humidity control to a higher setting. MAX is the highest setting. • When e xcess moisture and dampness odors are gone, adjust ...

  • Heat Controller BHD-301-C - page 6

    — 6 — 1.5.1 HO W DOES THE DEHUMIDIFIER WORK? Moist, humid air is drawn over a cold refrigerated dehumidifying coil. Moisture in the air condenses on this coil and drains into a bucket (or through the bucket into a hose and drain). Dry, clean air is drawn over the condenser where it is actually heated several degrees and discharged out the rear ...

  • Heat Controller BHD-301-C - page 7

    —7— 1.5.5 HUMIDITY CONTROLLER 1.5.5.1 Mechanical Type The humidity control can be set anywhere between Off and Max for normal operation. If you need more dehumidification, turn the Humidity Control toward Max. If you need less dehumidification, turn the Humidity Control toward Off. The relative humidity range is from 20% to 80%. (See Figure 6) ...

  • Heat Controller BHD-301-C - page 8

    —8— 2. CIRCUIT DIA GRAM • MODEL : BHD-301- C Q'TY PER SET 1 1 1 1 1 1 1 1 1 1 1 RE- MARKS S S S S S S S S S S S 1 2 3 4 5 6 7 8 9 10 11 DESCRIPTION POWER CORD ASSEMBLY SWITCH, ROCKER MOTOR ASSEMBLY CAPACITOR COMPRESSOR, SET OLP PWB(PCB) ASSEMBLY, DISPLAY SENSOR ASSEMBLY SWITCH ASSEMBLY, ROTARY SWITCH ASSEMBLY, MICRO PWB(PCB) ASSEMBLY, MA ...

  • Heat Controller BHD-301-C - page 9

    —9— W I R I N G W I R I N G D I A G R A M D I A G R A M M A I N P C B M A I N P C B C N - S / VA L V E C N - S / VA L V E C N - F A N C N - F A N R E V E R S I N G R E V E R S I N G C O I L C O I L B K ( H I ) B K ( H I ) Y L ( C O M ) O R ( C O M ) R D ( L O W ) R D ( L O W ) M O T O R M O T O R G N / Y L G N / Y L W H ( B L ) ( N ) W H ( B L ...

  • Heat Controller BHD-301-C - page 10

    3.1 MECHANICAL P AR TS 3.1.1 BUCKET AND AIR FIL TER 1. Turn the Humidity Control off(Mechanical type) or press the power button off. (Electronic type) 2. Disconnect the power supply. 3. Remove the bucket. (See Figure 9) 4. Pull out the air filter. (See Figure 10) 3.1.2 FRONT CASE AND REAR GRILLE 1. Remove 2 screws which fasten the front grille. 2. ...

  • Heat Controller BHD-301-C - page 11

    3.2 CONTR OL P ARTS 3.2.1 PO WER CORD ASSEMBL Y 1. After opening the control box, remove the screw that holds the ground wire. (See Figure 15) 2. Disconnect the remaining leads of the power cord from the PWB(PCB) ASSEMBLY, MAIN, then remove it from the control box. 3.2.2 SENSOR ASSEMBL Y 1. Disconnect the sensor assembly from the PWB(PCB) ASSEMBLY, ...

  • Heat Controller BHD-301-C - page 12

    — 12 — 3.2.6 COIL ASSEMBL Y , SOLENOID (BHD-501- B , BHD-651- C ) 1. Disconnect the housing of the COIL ASSEMBLY, SOLENOID from the PCB(PWB) ASSEMBLY, MAIN. 2. Remove the screw that fastens the COIL ASSEMBLY, SOLENOID. (See Figure 19) 3. Pull it out upwards. 3.2.7 CONTROL P ANEL 3.2.7.1 CONTROL PANEL - Mechanical Type (BHD-301- C ) 1. Disconnec ...

  • Heat Controller BHD-301-C - page 13

    3.2.8 F AN AND MO T OR 1. Turn the nut left and full out the Fan by hands carefully. 2. Remove 2 screws that fasten Heat Exchange. 3. Lift the H/E and open the H/E around 45 degree clockwise carefully. (See Figure 22) 4. Unfasten 3 screws that secure the Motor and earth wire. (See Figure 23) 5. Remove the Motor. 3.2.9 SHROUD AND DRAIN P AN 1. Disch ...

  • Heat Controller BHD-301-C - page 14

    —14— 3.3 REFRIGERA TING CYCLE 3.3.1 CONDENSER, EV APORA T OR AND CAPILLAR Y TUBE 1. Remove the insulation on the Heater/Evaporator (H/E) assembly 2. Pierce the pinch-off tube to discharge the refrigerant, using a refrigerant recovery system. 3. After discharging the refrigerant completely, remove 2 screws between the housing assembly and the H/ ...

  • Heat Controller BHD-301-C - page 15

    —15— 1. When replacing a refrigeration component, be sure to discharge the refrigerant system by using a refrigerant recovery system. 2. After discharging the unit completely, remove the desired component, and unbraze the pinch-off tubes. 3. Solder service valves into the pinch-off tube ports, leaving the valves open. 4. Solder the pinch-off tu ...

  • Heat Controller BHD-301-C - page 16

    — 16 — Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment. pinch-off tool capable of making a vapor-proof seal, leak detector, tubing cutter, hand tools to remove components, service valve. B A COMPRESSOR COMPOUND GAUGE MANIFOLD GAUGE SEE INSETS BELOW EXTERNAL VACUUM PUMP CHARGING CYLINDER HI LOW A B A B C CONDE ...

  • Heat Controller BHD-301-C - page 17

    CONDITION 1. Dehumidifier does not start. (Both compressor and fan motor do not operate.) 2. Motor runs but compressor does not run. 3. Does not defrost control. 4. Insufficient dehumidification CAUSE No power Poor plug contact at outlet. Bucket is full. Humidity control is at Off position Wire disconnected or loose Capacitor. (Discharge capacitor ...

  • Heat Controller BHD-301-C - page 18

    —18— CONDITION 5. Noisy operating 6. Water drips 7. Compressor cycles on overload protector. (OLP) CAUSE Fan Loose foreign material inside the housing. Tube hits frame. Fan blade hits frame Internal compressor noise. Loose set screws Worn bearings of Motor Assembly The bucket is not installed properly. Connection may be loose. Leak in bucket Wa ...

  • Heat Controller BHD-301-C - page 19

    —19— 5. EXPLODED VIEWS • MODEL: BHD-301-C 131400 349600 149980 165010 346811 359012 264110 148391 144410 752140 152302 436500 249950 266010 130410 235512 149410 435300 330870 266003 238310 135312 268711-1 266002 1 2 3 4 5 6 7 8 9 O f f M a x H g i h L o w d e e p S n a F l o r t n o C y t i d i m u H A u t o S h u t - O f f W0CZZ-2 268711-2 5 ...

  • Heat Controller BHD-301-C - page 20

    —20— • MODEL: BHD-501-B W0CZZ-2 165010 268711-2 264110 249950 35211A 352113 552204 567502 554160 550140 354210 554030 135312 131400 148391 144410 752140 152302 436500 130410 2 355 12 266010 238310 435300 330870 W0CZZ 349600 149980 346811 359012 268711-1 ...

  • Heat Controller BHD-301-C - page 21

    —21— • MODEL: BHD-651-C W0CZZ-2 165010 268711-2 264110 249950 35211A 552204 352113 567502 554160 550140 354210 135312 554030 131400 349600 149980 346811 359012 148391 144410 752140 152302 436500 130410 235512 266010 238310 435300 330870 W0CZZ 268711-1 ...

  • Heat Controller BHD-301-C - page 22

    —22— 6. REPLA CEMENT P AR TS LIST • MODEL: BHD-301-C 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A10285D 330870 DRAIN PAN ASSEMBLY 3087A10019C 148391 TANK ASSEMBLY,BUCKET 4839A10002A 149410 KNOB ASSEMBLY 4941A30019B 152302 FILTER(MECH),AIR 5230A20040A 165010 SENSOR ASEMBLY 6877A30013L 249950 CO ...

  • Heat Controller BHD-301-C - page 23

    —23— • MODEL: BHD-501-B 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A18012C 330870 DRAIN PAN ASSEMBLY 3087A10019C 148391 TANK ASSEMBLY,BUCKET 4839A10002A 152302 FILTER(MECH),AIR 5230A20040A 165010 SENSOR ASEMBLY 6877A30013L W0CZZ-2 CAPACITOR 0CZZA20005J 249950 CONTROL BOX,ASSEMBLY 4995A20622Y 2 ...

  • Heat Controller BHD-301-C - page 24

    —24— • MODEL: BHD-651-C 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A18012C 330870 DRAIN PAN ASSEMBLY 3087A10019E 148391 TANK ASSEMBLY,BUCKET 4839A10002A 152302 FILTER(MECH),AIR 5230A20040A 165010 SENSOR ASEMBLY 6877A30013L W0CZZ CAPACITOR 3H00660V 249950 CONTROL BOX,ASSEMBLY 4995A20622Y 264110 ...

  • Heat Controller BHD-301-C - page 25

    — 25 — MEMO ...

  • Heat Controller BHD-301-C - page 26

    — 26 — MEMO ...

  • Heat Controller BHD-301-C - page 27

    Specifications and performance data subject to change without notice. HEA T CONTROLLER, INC. 1900 WELL W OR TH A VENUE • JA CKSON, MICHIGAN 49203 THE QU ALITY LEADER IN CONDITIONING AIR P/No.: MFL38891301 ...

メーカー Heat Controller カテゴリー Dehumidifier

Heat Controller BHD-301-Cのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BHD-301-Cの取扱説明書
- Heat Controllerの製品カード
- パンフレット
- またはHeat Controller BHD-301-Cの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Heat Controller BHD-301-Cの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Heat Controller BHD-301-Cの取り付け説明書、サービスマニュアル、簡易説明書、またはHeat Controller BHD-301-Cのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Heat Controller BHD-301-Cの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Heat Controller BHD-301-Cデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHeat Controller BHD-301-Cを使用するのを助ける技術的文書のことです。説明書は通常、全てのHeat Controller BHD-301-Cユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Heat Controllerの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Heat Controller BHD-301-Cの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHeat Controller BHD-301-Cの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Heat Controller BHD-301-Cに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Heat Controller BHD-301-Cデバイスの基本機能を使うにあたってのヒント。 Heat Controller BHD-301-Cのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Heat Controller BHD-301-Cに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHeat Controller BHD-301-Cのメーカー/サービスへの連絡先に関する情報。

Heat Controller BHD-301-Cについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHeat Controller BHD-301-Cの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHeat Controller BHD-301-Cで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)