    MODEL CO5120B—User’ s Manual AC Powered Carbon Monoxide Alarm W ith Batter y Back-Up M06-1046-001 6/00 120V AC 60 Hz .085A Standby .087A Alarm Model CO5120B ...

  • BRK electronic CO5120B - page 2

    1 T ABLE OF CONTENTS CHAPTER 1: INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 How Y our CO Alarm W orks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • BRK electronic CO5120B - page 3

    2 CHAPTER 1: Introduction BASIC SAFETY INFORMATION IMPORT ANT ! Dangers, W ar nings, and Cautions alert you to important operating instructions or to potentially hazardous situations. Pay special attention to these items. IMPORT ANT ! THIS IS NOT A SMOKE ALARM! This CO alarm is designed to detect carbon monoxide from ANY source of combustion. It is ...

  • BRK electronic CO5120B - page 4

    3 HOW Y OUR CO ALARM WORKS The Cover Of Y our CO Alarm General Information This CO alarm is designed to be hard-wir ed and mounted on any standard size wiring junction box, up to 4” diagonal size. When fully powered, this CO alarm samples the air and takes a new reading about every second. A microchip inside the unit stor es each reading, and rem ...

  • BRK electronic CO5120B - page 5

    4 Basic Operation Normal Operation. • Horn is silent. • Red light (LED) is on continuously . During T esting • Horn pattern repeats twice: 4 beeps, pause, 4 beeps, pause. • Red light (LED) flashes once per second during the 10-second test cycle. During An Alarm • Continuous repeating horn pattern: 4 beeps, pause, 4 beeps, pause. • Red ...

  • BRK electronic CO5120B - page 6

    5 CO ALARM SPECIFICATIONS Gas Detection at T ypical T emperature and Humidity Ranges: The CO alarm is not formulated to detect CO levels below 30 ppm typically . UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). V alues ...

  • BRK electronic CO5120B - page 7

    6 CHAPTER 2: Installation WHERE TO INSTALL CO ALARMS The Consumer Product Safety Commission (CPSC) recommends the use of at least one CO alarm per household, located near the sleeping area. For added pr otection, install additional CO alarms in each separate bedroom, and on every level of your home. If your bedroom hallway is longer than 40 feet, i ...

  • BRK electronic CO5120B - page 8

    7 WHERE NOT T O INSTALL CO ALARMS DO NOT locate this CO alarm: • In garages, kitchens, furnace rooms, or in any extremely dusty , dirty or greasy ar eas. • Within 5 feet of any cooking appliance. The alarm should be between 5 and 20 feet from any cooking appliance. • Closer than 20 feet from a furnace or other fuel burning heat source, or fue ...

  • BRK electronic CO5120B - page 9

    8 USING THE OPTIONAL LOCKING FEATURES The optional locking featur es ar e designed to prevent unauthorized r emoval of the battery or alarm. It is not necessary to activate the locks in single-family households wher e unauthorized battery or alarm removal is not a concern. These CO alarms have two separate locking features: one locks the battery co ...

  • BRK electronic CO5120B - page 10

    9 3. Push the locking pin thr ough the black dot on the label on the back of the CO alarm. T O UNLOCK THE BATTERY COMPARTMENT: IMPORT ANT ! Once the CO alarm is installed, you must disconnect it from the AC power befor e unlocking the battery compartment. DANGER ! ELECTRICAL SHOCK HAZARD. T urn off the power to the area wher e the CO alarm is insta ...

  • BRK electronic CO5120B - page 11

    10 The Mounting Bracket Lock T ools you will need: • Needle-nose pliers • Standard/Flathead scr ewdriver T O ACTIVATE THE BRACKET LOCK: 1. Using needle-nose pliers, detach one locking pin from the mounting bracket. 2. Insert the locking pin into the lock located on the pivoting hinge of the battery door . 3. When you attach the CO alarm to the ...

  • BRK electronic CO5120B - page 12

    11 2. Pry the CO alarm away fr om the bracket by turning both the screwdriver and the CO alarm clockwise (right) at the same time. TO PERMANENTL Y REMOVE THE BRACKET LOCK: Insert the flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock. HOW TO INSTALL Y OUR CO ALARM This unit is designed to be mounted on any s ...

  • BRK electronic CO5120B - page 13

    12 N OTE: A qualified appliance technician is defi ned as “a person, firm, corporation, or company that either in person or thr ough a repr esentative, is engaged in and r esponsible for the installation, testing, servicing, or r eplacement of heating, ventilation, air conditioning (HV AC) equipment, combustion appliances and equipment, and/or ...

  • BRK electronic CO5120B - page 14

    13 SINGLE-STATION INST ALLA TION T ools needed: Standard/Flathead scr ewdriver . DANGER ! ELECTRICAL SHOCK HAZARD. T urn off power to the area wher e you will install this unit at the circuit br eaker or fuse box before beginning installation. Failure to turn of f the power before installation may r esult in serious electrical shock, injury or deat ...

  • BRK electronic CO5120B - page 15

    14 INTERCONNECTING MUL TIPLE CO ALARMS Interconnecting Multiple CO Alarms Interconnected units can pr ovide earlier warning of a CO problem than stand-alone units, especially if the problem starts in a r emote area of the dwelling. If any unit in the series senses CO, all units will alarm. T o determine which CO alarm initiated an alarm, refer to t ...

  • BRK electronic CO5120B - page 16

    15 TO INST ALL: 1. Remove the mounting bracket fr om the base. Position the screw slots on the mounting bracket over the screws in the junction box. Tighten the screws. 2. Strip of f about 1/2” of the plastic coating on the violet interconnect wir e on the power connector . 3. Using wir e nuts, connect the power connector to the AC power . • Co ...

  • BRK electronic CO5120B - page 17

    16 6. Make sur e each unit is receiving AC power . Under normal operation, the red light (LED) will shine continuously . 7. T est each CO alarm. Press and hold the test button until the unit alarms: 4 beeps, pause, 4 beeps, pause. IMPORT ANT ! In a series of interconnected alarms, you must test each alarm separately by pressing and holding the test ...

  • BRK electronic CO5120B - page 18

    17 Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers dir ectly , for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. W rite down the num ...

  • BRK electronic CO5120B - page 19

    18 The “Latching Alarm” Indicator: GARAGE BEDROOM BEDROOM HALL LIVING ROOM KITCHEN BASEMENT BEDROOM LA TCHING ALARM: Unit was exposed to alarm levels of CO LA TCHING NOT ACTIV A TED: Unit was not exposed to alarm levels of CO KEY : The Latching Alarm Indicator is activated after a CO alarm is exposed to alarm levels of carbon monoxide. After CO ...

  • BRK electronic CO5120B - page 20

    19 CHAPTER 4: T esting and Maintenance W eekly T esting Push and hold the T est/Silence button on the cover until a loud alarm sounds— 4 beeps, a pause, then 4 beeps. The alarm sequence should last for 10 seconds. If the alarm ever fails to test properly , replace it immediately . If the CO alarm is not working properly , refer to Chapter 10: “ ...

  • BRK electronic CO5120B - page 21

    20 CHAPTER 5: What Y ou Need T o Know About CO What is CO? CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely , or are exposed to heat (usually fire). Electrical appliances typically do not produce CO. These fuels include: W ood, coal, charcoal, oil, natural gas, gasoline, kerosene, and pr opane. Common a ...

  • BRK electronic CO5120B - page 22

    21 Potential Sources Of CO In The Home Fuel-burning appliances like: portable heater , gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer . Damaged or insuf fi cient venting: corr oded or disconnected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger , blocked or clogged chimney opening. ...

  • BRK electronic CO5120B - page 23

    22 How Can I Protect My Family? A CO alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before Carbon Monoxide levels become threatening for average, healthy adults. A CO alarm is not a substitute for proper maintenance of home appliances. T o help prevent CO pr oblems and reduce the risk of CO poisoning: • Cle ...

  • BRK electronic CO5120B - page 24

    23 CHAPTER 6: Underwriters Laboratories Inc. UL2034 What Levels of CO Cause an Alarm? Underwriters Laboratories Inc. UL2034 defines 3 specific alarm points by which all residential CO alarms must alarm. They are measur ed in parts per million (ppm) of CO over time (in minutes). UL2034 Required Alarm Points: • If the alarm is exposed to 400 ppm ...

  • BRK electronic CO5120B - page 25

    24 CHAPTER 7: Troubleshooting Guide DANGER! ELECTRICAL SHOCK HAZARD. T ur n off the power to the ar ea where the CO alarm is installed BEFORE removing it from the mounting bracket or checking any electrical connections! Failur e to turn off the power fi rst may result in serious electrical shock, injury or death. The following guide can help you i ...

  • BRK electronic CO5120B - page 26

    25 UNDERSTANDING THE LIGHT AND HORN PATTERNS (AC POWER ON) When the CO Alarm is operating on AC power ... Condition LED (Red Light) Horn POWER UP LED flashes ON once, then shines continuously Horn “chirps” once. DURING TESTING LED flashes once every second during the 10-second test cycle Horn patter n: 4 beeps, pause, 4 beeps, pause. MISSING ...

  • BRK electronic CO5120B - page 27

    26 UNDERSTANDING THE LIGHT AND HORN PATTERNS (AC POWER OFF) When AC power is Off, and CO alarm is operating on battery back-up... Condition LED (Red Light) Horn BA TTERY BACK-UP POWER UP LED flashes ON once, then flashes once per minute Horn “chirps” once. DURING TESTING LED flashes once every second during the 10-second test cycle Horn patt ...

  • BRK electronic CO5120B - page 28

    27 CHAPTER 8: General Limitations Of CO Alarms This CO alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for carbon monoxide detectors must be met. CO alarms will not work without power . This CO alarm requir es a continuous supply of ...

  • BRK electronic CO5120B - page 29

    NOTES ...

  • BRK electronic CO5120B - page 30

    29 NOTES ...

  • BRK electronic CO5120B - page 31

    Limited W arranty BRK Brands, Inc. warrants the enclosed Carbon Monoxide Alarm to be free fr om defects in materials and workmanship under normal use and service for a period of five years from date of purchase. BRK Brands, Inc. makes no other express warranty for this alarm. No agent, repr esentative, dealer , or employee of the Company has the a ...

メーカー BRK electronic カテゴリー Smoke Alarm

BRK electronic CO5120Bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CO5120Bの取扱説明書
- BRK electronicの製品カード
- パンフレット
- またはBRK electronic CO5120Bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、BRK electronic CO5120Bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、BRK electronic CO5120Bの取り付け説明書、サービスマニュアル、簡易説明書、またはBRK electronic CO5120Bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、BRK electronic CO5120Bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

BRK electronic CO5120Bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBRK electronic CO5120Bを使用するのを助ける技術的文書のことです。説明書は通常、全てのBRK electronic CO5120Bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

BRK electronicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. BRK electronic CO5120Bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBRK electronic CO5120Bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。BRK electronic CO5120Bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. BRK electronic CO5120Bデバイスの基本機能を使うにあたってのヒント。 BRK electronic CO5120Bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。BRK electronic CO5120Bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBRK electronic CO5120Bのメーカー/サービスへの連絡先に関する情報。

BRK electronic CO5120Bについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBRK electronic CO5120Bの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBRK electronic CO5120Bで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)