Regency H2100の取扱説明書

20ページ 1.17 mb
ダウンロード

ページに移動 of 20

Summary
  • Regency H2100 - page 1

    FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 908-332b MODELS: H2100 I3100L WOOD Fireplace Insert & Hearth Heater 03/06/08 Owners & Installation Manual T ested by: Installer : Please complete the details on the back cover and leave this manual with the homeowner . Homeowner: Please keep these instr ...

  • Regency H2100 - page 2

    Regency Wood Insert & Hearth Heater 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those ...

  • Regency H2100 - page 3

    Regency Wood Insert & Hearth Heater 3 REGENCY FIREPLACE INSERTS & HEARTH HEA TER T ABLE OF CONTENTS SAFETY LABEL Safety Label For I3100L ................................................ 4 Safety Label For H2100M.............................................. 5 INST ALLA TION Before Installing Y our Insert..................................... ...

  • Regency H2100 - page 4

    Regency Wood Insert & Hearth Heater 4 LISTED F ACTORY BUIL T FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U.S.A. MODEL: I3100L TESTED TO: ULC S628-M93 / UL 1482-1998 / ULC S627-00 / UL 737-2000 REPORT NO. 632-323500 (MAR.1994) DO NOT REMOVE THIS LABEL 106 COMPONENTS REQUIRED FOR INST ALLA TION: 6" (150mm) ST AINLESS STEEL LINER. OPTION ...

  • Regency H2100 - page 5

    Regency Wood Insert & Hearth Heater 5 SAFETY LABEL This is a copy of the label that accompanies each Regency Hearth Heater . We have printed a copy of the contents here for your review . 103 DO NOT REMOVE BRICKS OR MORT AR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONL Y . DO NOT USE GRATE OR ELEV A TE FIRE. BUILD WOOD FIRE DIRECTLY ON ...

  • Regency H2100 - page 6

    Regency Wood Insert & Hearth Heater 6 INST ALLA TION CHIMNEY SPECIFICA TIONS Before installing, check and clean your chimney system thoroughly . If in doubt about its condi- tion, seek professional advice. Y our Regency Insert is designed for installation into a masonry fi replace that is constructed in accordance with the requirements of &quo ...

  • Regency H2100 - page 7

    Regency Wood Insert & Hearth Heater 7 Clearance diagram for installations INST ALLA TION Side and T op facing is a maximum of 1.5" thick. Floor protection must non-combustible, insula- tive material with an R value of 1.1 or greater . * If the hearth extension is fl ush with the fl oor (F) it must extend 19.5" in front of the body f ...

  • Regency H2100 - page 8

    Regency Wood Insert & Hearth Heater 8 1) Positive Flue Connection with Cleanout FLUE CONNECT OR BRACKET Package contains: 3 brackets and 6 screws. These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the connection. The brackets are screwed into the top of the Insert in the pre-punched holes and then scre ...

  • Regency H2100 - page 9

    Regency Wood Insert & Hearth Heater 9 INST ALLA TION Diagram 1: H2100M and I3100L Faceplate Assembly A) H2100M and I3100L Insert 1) Slide the spring nuts (supplied) over the slots in the insert’s side convection panels (the spring nuts may need to be squeezed with a pair of pliers fi rst, to help them stay in position). 2) Screw the side fac ...

  • Regency H2100 - page 10

    Regency Wood Insert & Hearth Heater 10 Ground Fan Fan Ground Green Neutral Live White Fan Switch Manual/ Auto Switch Black Black High (Black) Low (Red) Black Fan Thermodisc (normally open) 120V AC 60 Hz Thermo Switch Sensor Thermo Switch Sensor INST ALLA TION F AN / BLOWER Blower/Fan Wiring Diagram 3) Slide the supports into the clips. The tens ...

  • Regency H2100 - page 11

    Regency Wood Insert & Hearth Heater 11 BRICK FLUE BAFFLE & SECONDAR Y AIR TUBE INST ALLA TION The fl ue baf fl e system located in the upper area of the fi rebox is removable to make cleaning your chimney system easier . The brick baf fl es must be installed prior to your fi rst fi re. Smoke spillage and draft problems may occur if th ...

  • Regency H2100 - page 12

    Regency Wood Insert & Hearth Heater 12 Pull Open Push Closed INST ALLA TION Hearth Heater (H2100M) Steel Baf fl e Place the insulation batt on top of the baf fl e. Make sure that this batt is laying fl at and does not obstruct the smoke from getting up the fl ue opening. This insulating batt may be wrapped in paper for handling purposes and ...

  • Regency H2100 - page 13

    Regency Wood Insert & Hearth Heater 13 automatic temperature sensor will engage the blower when the unit is at temperature and will shut off the blower once the fi re has gone out and the unit has cooled to below a useful heat output range. T o manually operate the fan system, push the fi rst switch to "Man" and second switch to eit ...

  • Regency H2100 - page 14

    Regency Wood Insert & Hearth Heater 14 6) Do not permit creosote or soot buildup in the chimney system. Check and clean chimney at regular intervals. 7) Y our Regency Insert can be very hot. Y ou may be seriously burned if you touch the insert while it is operating. W arn children of the burn hazard. 8) The insert consumes air while operating, ...

  • Regency H2100 - page 15

    Regency Wood Insert & Hearth Heater 15 I3100 MAIN ASSEMBL Y Part # Description 846-910 Door Assembly-Large Gold (I3100)-no glass 846-916 Door Assembly-Large Black (I3100)-no glass 3) 846-304 Glass - Replacement - (I3100) 4) 936-243 7/8" Adhesive T ape Gasket 5) 846-920 Glass Retainer Clips (set of 8) 6) * Screw 1/4-20 x 3/8" 7) 948-17 ...

  • Regency H2100 - page 16

    Regency Wood Insert & Hearth Heater 16 P ARTS LIST I3100 F ACEPLA TES Part # Description Faceplate: I3100L 163-910 Faceplate & T rim Set - Regular 385) 163-165 Trim Right Regular 386) 163-160 Trim T op Regular 387) 163-161 Trim Left Regular 388) * Faceplate Side Regular 389) * Faceplate T op Regular 163-912 Faceplate & T rim Set - Overs ...

  • Regency H2100 - page 17

    Regency Wood Insert & Hearth Heater 17 H2100 MAIN ASSEMBL Y Part # Description Part # Description 1) 846-910 Door Assembly-Large Gold - no glass 846-916 Door Assembly-Large Black - no glass 3) 846-304 Glass - Replacement 4) 936-243 7/8" Adhesive T ape Gasket 5) 846-920 Glass Retainer Clips (set of 8) 6) * Screw 1/4-20 x 3/8" 7) 948-17 ...

  • Regency H2100 - page 18

    Regency Wood Insert & Hearth Heater 18 P ARTS LIST I3100 & H2100 FIREBRICK Part # Description 70) 902-1 1 1 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) 802-104 Brick Partial: 1-1/4" x 4" x 9" 72) 802-146 Brick Partial: 1-1/4" x 1-3/4" x 9" 75) 802-139 Brick Partial: 1-1/4" x 4" x ...

  • Regency H2100 - page 19

    Regency Wood Insert & Hearth Heater 19 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to ...

  • Regency H2100 - page 20

    Printed in Canada Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________________________________________ ...

メーカー Regency カテゴリー Indoor Fireplace

Regency H2100のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- H2100の取扱説明書
- Regencyの製品カード
- パンフレット
- またはRegency H2100の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Regency H2100の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Regency H2100の取り付け説明書、サービスマニュアル、簡易説明書、またはRegency H2100のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Regency H2100の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Regency H2100デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRegency H2100を使用するのを助ける技術的文書のことです。説明書は通常、全てのRegency H2100ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Regencyの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Regency H2100の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRegency H2100の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Regency H2100に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Regency H2100デバイスの基本機能を使うにあたってのヒント。 Regency H2100のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Regency H2100に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRegency H2100のメーカー/サービスへの連絡先に関する情報。

Regency H2100についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRegency H2100の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRegency H2100で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください