Omega Vehicle Security LDN-PSの取扱説明書

28ページ 1.2 mb
ダウンロード

ページに移動 of 28

Summary
  • Omega Vehicle Security LDN-PS - page 1

    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide LDN-PS Shop online at solartron 6 9 5 1 ...

  • Omega Vehicle Security LDN-PS - page 2

    Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified S tamford CT 06907-0047 T el: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada T el: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales ...

  • Omega Vehicle Security LDN-PS - page 3

    1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . .3 Service Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 T erms and Symbols in this manual . . . . . . . . . . ...

  • Omega Vehicle Security LDN-PS - page 4

    PSIM-AC PSIM-DC PSIM-5V Introduction The Power Supply Interface Module (PSIM) is part of the Orbit Measurement System. The PSIM provides local power to the network when required. Example uses: • Power via the communications cable is not suf ficient due to cable voltage drop s. • The controlling computer is not suitable to supply the Orbit Netwo ...

  • Omega Vehicle Security LDN-PS - page 5

    This equipment is designed as safety Class 1 apparatus to comply with EN61010-1. Service Safety This equipment has been designed and tested to meet the requirements of the Low V oltage Directive (1997) and has been supplied in a safe condition. This manual contains information and warnings that must be followed by the user to ensure safe operation ...

  • Omega Vehicle Security LDN-PS - page 6

    W ARNING: Danger arising from loss of ground. During a fault condition and upon loss of protective ground (earth), all accessible conducting part s - including controls that might appear to be insulated - can render an electric shock. W ARNING: Grounding the equipment. The unit is grounded through the mains lead: to avoid electric shock, plug the p ...

  • Omega Vehicle Security LDN-PS - page 7

    3.0: General Information PSIM-AC PSIM-DC PSIM-5V LDN-PS 6 M-3340/1206 6 9 51 Power Supply OUTPUT PSIM V ariant s 6 9 51 Power Supply OUTPUT 6 9 51 Power Supply OUTPUT PSIM-AC T o power Orbit Modules from a local mains supply PSIM-DC T o power Orbit Modules from a local DC supply , such as 24V Input: 90 - 230 V AC Output: 5 VDC to Orbit Network IEC ...

  • Omega Vehicle Security LDN-PS - page 8

    LDN-PS 7 M-3340/1206 3.0: General Information (continued) PSIM-AC PSIM-DC PSIM-5V PSIM General Layout PSIM 911173 1 7 3 A 1 2 3 R 0 1 6 9 5 1 Power Supply OUTPUT 6 9 51 Power Supply OUTPUT *Cable Lengths • PSIM-AC and PSIM-DC have a fixed 2m cable between PIE and power supply . • PSIM-DC and PSIM-5V input cables are supplied 5m long. This may b ...

  • Omega Vehicle Security LDN-PS - page 9

    PSIM used in a small network configuration 3.0: General Information (continued) PSIM-AC PSIM-DC PSIM-5V LDN-PS 8 M-3340/1206 ...

  • Omega Vehicle Security LDN-PS - page 10

    4.0: PSIM Schematic and Pin-out The 5V power supply line from the network is isolated at the PSIM. All modules before the PSIM are powered from the network. Example: Orbit Network Card. All modules after the PSIM are powered from the external power supply connected via the PSIM. 0 V is common. 5 V to Orbit Network 5 V from Orbit Network (no pins on ...

  • Omega Vehicle Security LDN-PS - page 11

    4.0: PSIM Schematic and Pin-out (continued) The PSIM will only supply power to the Orbit Modules that follow the PSIM. Some typical configurations are shown. For more information about PSIM and Orbit Network connection, refer to the Applications section. Orbit Modules are designed to work from a supply voltage of 4.75 to 5.25 Vdc and care must be t ...

  • Omega Vehicle Security LDN-PS - page 12

    5.1 Power Supply The mounting plate must not be removed. The mounting plate is isolated and does not need to be at earth potential. The power supply may be mounted in any orientation. The power supply must not be exposed to fluids or excessive dust. Power supply cooling is by convection; allow room for air to flow around the unit. 5.0: Dimensions a ...

  • Omega Vehicle Security LDN-PS - page 13

    PSIM-AC PSIM-DC PSIM-5V 5.0: Dimensions and Mechanical Inst allation (continued) 5.2 PSIM T -CON is permanently att ached, module does not separate. For more information on mounting, refer to the Orbit Measurement System Manual. 6 9 5 1 6 9 51 Power Supply OUTPUT Power Supply OUTPUT LDN-PS 12 M-3340/1206 ...

  • Omega Vehicle Security LDN-PS - page 14

    PSIM-AC PSIM-DC PSIM-5V 6.0: S pecification Input V olt age 85 to 264 V ac @ 47 Hz to 440 Hz. Current 0.8 A Connection via IEC320 connector Isolation 2500 V ac input/output Protection Input fuse and filter (not user replaceable) Recommended Line Fuse 2A T (slo-blo) 250 V rating DC Output Output V olt age 5.1 Vdc Nominal Output Current 1.8 A max (i. ...

  • Omega Vehicle Security LDN-PS - page 15

    6.0: S pecification (continued) PSIM-AC PSIM-DC PSIM-5V Input Line V olt age 10 to 30 Vdc. Current 1.1 A @ 12 Vdc; 0.5 A @ 24 Vdc (nominal). Connection see note 3 5m flying lead (Red = positive, White = negative) Isolation >500 VDC input/output Protection Input fuse and filter (not user replaceable) Over voltage and under volt age shut down Reve ...

  • Omega Vehicle Security LDN-PS - page 16

    6.0: S pecification (continued) PSIM-AC PSIM-DC PSIM-5V Line V olt age see note 1 5.1 Vdc Nominal as supplied by user 5.25 Vdc MAX Input Current 1.8 A MAX Connection see note 3 5m flying lead (Red = positive, White = negative) Isolation None Protection see note 2 Current limiting resettable fuse Over voltage 1 12% to 132% of nominal Reverse connect ...

  • Omega Vehicle Security LDN-PS - page 17

    6.0: S pecification (continued) PSIM-AC PSIM-DC PSIM-5V Environment al Operational temperature 0 to 60 °C S torage temperature -20 to 60 °C Humidity 5% to 95% non-condensing Cooling Convection Protection Rating Power supply unit IP40 Protection Rating PSIM module IP53 Approvals EMC Susceptibility EN 50082-1 EMC Emission EN 50081-2 (note: ferrite ...

  • Omega Vehicle Security LDN-PS - page 18

    Orbit Network Power Supply Requirement s All Orbit Modules are designed to work from a supply voltage of 4.75V to 5.25 Vdc. When power is applied to a module its current consumption will cause a slight voltage drop across cables. Care must be t aken to ensure that all modules have the right working voltage applied. This section is for guidance only ...

  • Omega Vehicle Security LDN-PS - page 19

    7.0: Applications (continued) V olt age Drop Estimation The following information is for guidance only when planning an installation. V oltage measurements must still be made to ensure the right working voltage for each Orbit Module. 6 9 51 Power Supply OUTPUT PSIM-AC PSIM-DC PSIM-5V PSIM-AC PSIM-DC see note 1 volt drop (from no load output) V = 5. ...

  • Omega Vehicle Security LDN-PS - page 20

    PSIM-AC PSIM-DC PSIM-5V 7.0: Applications (continued) Application 1: Basic Small Network Connection. • Power supplied to network from PC via network card, no PSIM used. • Modules connected using standard communication cables. V olt drop tot al in mV = cable 1 + module (3 of f) + cable 2 + module (3 off) = (15.2 x 6) + 0.04(6+5+4+3+2+1) + (15.2 ...

  • Omega Vehicle Security LDN-PS - page 21

    PSIM-AC PSIM-DC PSIM-5V 7.0: Applications (continued) Application 2: Large network with modules close to computer and at a dist ance. • Power supplied from PC and PSIM (located at a distance from PC). • Communications via standard communications cable and custom cable. LDN-PS 20 M-3340/1206 ...

  • Omega Vehicle Security LDN-PS - page 22

    PSIM-AC PSIM-DC PSIM-5V 7.0: Applications (continued) V olt drop V 1 is calculated in a similar way to the previous example except there is only a single cable and 3 Orbit modules. The PSIM supplies power to remaining modules and are calculated separately . The long communications cable does not carry supply current and so has no af fect on volt dr ...

  • Omega Vehicle Security LDN-PS - page 23

    PSIM-AC PSIM-DC PSIM-5V 7.0: Applications (continued) Application 3: Large Network using PSIM-5V and RS232IM for network control. LDN-PS 22 M-3340/1206 ...

  • Omega Vehicle Security LDN-PS - page 24

    PSIM-AC PSIM-DC PSIM-5V The PSIM-5V is powering the whole Orbit Network. PSIM-5V volt drop is calculated using 12 as the total number of Orbit modules; the RS232IM is included in this number . T otal V oltage drop = PSIM-5V + modules (6 of f) + Cable 1 + Modules (6 of f) = (2 x 12 x [3+1]) + 0.04 (1+2+3+4+5+6+7+8+9+10+1 1+12)+ (15.2 x 6) + 0.04 (1+ ...

  • Omega Vehicle Security LDN-PS - page 25

    PSIM-AC PSIM-DC PSIM-5V 7.0: Applications (continued) Application 4: Modules located a long dist ance from computer . • Also for a computer that is not suit able for supplying power to Orbit Modules. • Power supplied from PSIM to modules. • Connection via long cable providing RS485, 0V reference and screening. LDN-PS 24 M-3340/1206 ...

  • Omega Vehicle Security LDN-PS - page 26

    7.0: Applications (continued) PSIM-AC PSIM-DC PSIM-5V Application 5: Use with RS232 Interface Module (RS232IM). • Communication is via a RS232IM. • Power to the RS232IM and Orbit Modules is via PSIM. LDN-PS 25 M-3340/1206 ...

  • Omega Vehicle Security LDN-PS - page 27

    M-3340/1206 W ARRANTY / DISCLAIMER OMEGA ENGINEERING , INC. warrant s this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s W arranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEG ...

  • Omega Vehicle Security LDN-PS - page 28

    Where Do I Find Everything I Need for Process Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com M-3340/1206 TEMPERA TURE  Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies  Wire: Thermocouple, R TD & Thermistor  Calibrators & Ice Point References  Recorders, Controllers & ...

メーカー Omega Vehicle Security カテゴリー Power Supply

Omega Vehicle Security LDN-PSのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LDN-PSの取扱説明書
- Omega Vehicle Securityの製品カード
- パンフレット
- またはOmega Vehicle Security LDN-PSの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Vehicle Security LDN-PSの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Vehicle Security LDN-PSの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Vehicle Security LDN-PSのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Vehicle Security LDN-PSの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Omega Vehicle Security LDN-PSデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Vehicle Security LDN-PSを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Vehicle Security LDN-PSユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Vehicle Securityの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Vehicle Security LDN-PSの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Vehicle Security LDN-PSの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Vehicle Security LDN-PSに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Vehicle Security LDN-PSデバイスの基本機能を使うにあたってのヒント。 Omega Vehicle Security LDN-PSのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Vehicle Security LDN-PSに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Vehicle Security LDN-PSのメーカー/サービスへの連絡先に関する情報。

Omega Vehicle Security LDN-PSについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Vehicle Security LDN-PSの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Vehicle Security LDN-PSで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)