    Installation Instructions T ype C Boilers G.C.N: 41-116-06 41-116-07 LEA VE THESE INSTRUCTIONS WITH THE END-USER Countr y of destination: GB ...

  • Ariston 41-116-07 - page 2

    2 T ABLE OF CONTENTS 1. GENERAL INFORMA TION 1.1 G ENERAL I NSTR UCTIONS 1.2 O VERALL V IEW 2. INST ALLA TION 2.1 R EFERENCE S T ANDARDS 2.2 S ITING THE A PPLIANCE 2.3 O VERALL D IMENSIONS 2.4 C LEARANCES 2.5 M OUNTING THE A PPLIANCE 2.6 E LECTRICAL C ONNECTION 2.7 G AS C ONNECTION 2.8 W A TER C ONNECTIONS 2.9 F LUE C ONNECTION 2.10 R OOM T HERMOST ...

  • Ariston 41-116-07 - page 3

    This manual is an integr al and essential par t of the product. It should be k ept with the appliance so that it can be consulted by the user and our authorised personnel. Please carefully read the instructions and notices about the unit contained in this manual, as they pro vide impor tant information regarding the saf e installation, use and main ...

  • Ariston 41-116-07 - page 4

    4 4 - Visual check of the comb ustion process or analysis of comb ustion by- products (see section 4.5) and cleaning of the burner if needed. 5 - If called f or by point. 3, dismantling and cleaning of the comb ustion chamber . 6 - If called f or by point. 4, dismantling and cleaning of the b urner jets. 7 - Visual check of the primar y heat e xcha ...

  • Ariston 41-116-07 - page 5

    5 The technical inf or mation and instructions provided herein below are intended f or the installer so that the unit ma y be installed correctly and saf ely . The installation and initial star t up of the boiler must be by a CORGI Registered Installer in compliance with the installation standards currently in eff ect, as well as with any and all l ...

  • Ariston 41-116-07 - page 6

    F or saf ety pur poses, ha v e a competent person carefully check the electrical system in the proper ty , as the manuf acturer will not be held liab le f or damage caused by the f ailure to ear th the appliance properly or by anomalies in the supply of power . Make sure that the residential electrical system is adequate for the maximum po wer abso ...

  • Ariston 41-116-07 - page 7

    V IEW OF THE B OILER C ONNECTIONS L EGEND : A = Central Heating Flow C = Gas Inlet E = Central Heating Return F = Saf ety V alve G = Pump transpor tation screw (remov e bef ore igniting the boiler) H = A utomatic By-pass pipe C ENTRAL H EA TING Detailed recommendations are given in BS 6798:1987 and BS 5449-1:1990, the f ollowing notes are giv en f ...

  • Ariston 41-116-07 - page 8

    8 P IPE W ORK : Copper tubing to BS EN 1057:1996 is recommended f or water pipes . Jointing should be either with capillar y soldered or compression fittings. Where possible pipes should ha v e a gradient to ensure air is carried naturally to air release points and water flo ws naturally to dr ain taps. The appliance has a built-in automatic air re ...

  • Ariston 41-116-07 - page 9

    Ø 60/100 mm F IG . 2.6 A BC D E F G J K HI L G F The boiler is designed to be connected to a coaxial flue discharge system. 9 2.9 F LUE C ONNECTIONS F LUE S YSTEM The provision f or satisf actory flue ter mination must be made in accordance with BS 5440-1. The appliance must be installed so that the flue terminal is exposed to outside air . The te ...

  • Ariston 41-116-07 - page 10

    Ø 80 mm In addition, it is also possible to use a split (twin pipe) system by fitting a special adaptor to the flue connector and using the aper ture for the air v ent intak e located on the top par t of the combustion chamber . T o utilise the air intake it is necessar y to: 1. Remov e the bottom of the air intake b y cutting it with a suitable k ...

  • Ariston 41-116-07 - page 11

    L = Sum of the total length of exhaust + air intak e piping. 11 Exhaust T ype C12 (xx) C32 (xx) C42 (xx) Restrictor ø 46 mm L min = 0.5 m L max = 1 m Maximum Extension Exhaust/Air L = 4 m Risk of Condensation Forming Coaxial Systems ø 60/100 Piping not insulated ø 46 restrictor NO restrictor NONE NONE Piping insulated ø 46 restrictor NO restric ...

  • Ariston 41-116-07 - page 12

    12 T o connect a room ther mostat and/or time clock, it is necessar y to: 1. - Open the control panel as indicated in section 4.3; 2.- Remove scre ws “ A ” and remov e the inspection co ver from the re verse of the control panel; 3. - F or the room-ther mostat connect the ther mostat switching wires to the position 5 and 6 and remov e the wire ...

  • Ariston 41-116-07 - page 13

    2.11 E LECTRICAL D IA GRAM 13 F IG . 2.12 L EGEND : A - On/Off Switch B - On/Off L.E.D . C - Heating Switch D - Heating L.E.D . E - Reset Button F - Ignition F ailure (Loc k out) L.E.D . A01 - Pump Pressure Switch A02 - F rost Ther mostat A03 - Modulator A04 - Circulation Pump A05 - Regulation Thermostat A06 - Exter nal Control System A07 - Time Cl ...

  • Ariston 41-116-07 - page 14

    14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L EGEND : 1. F an 2. Main heat e xchanger 3. Overheat thermostat 4. Bur ner 5. Ignition electrodes 6. Detection electrode 7. Regulation ther mostat 8. F rost thermostat 9. Gas valv e 10. Pump pressure s witch 11. Saf ety valv e (3 bar) 12. Boiler drain v alv e 13. A utomatic by-pass 14. Pressure gauge 15 ...

  • Ariston 41-116-07 - page 15

    15 3. D .H.W . ST ORA GE CYLINDER The microSYSTEM can be connected to a storage cylinder (both open-v ented and unv ented) f or the production of domestic hot water (D .H.W .). Cylinders of different capacities can be used depending on site requirements (see T ABLE 3.1 f or a selection of ARIST ON unv ented cylinders). F IG . 3.2 3 port valve insta ...

  • Ariston 41-116-07 - page 16

    16 T echnical Data Capacity Coil C.H.W . D .H.W . Max Heating Heat Ioss Surface Flow/rate Flo w/rate Output MODEL It. m 2 m 3 /h It/h kW kWh/24h Contract STI 125 Indirect 125 0.75 0.5 194 11.3 2 1 266 15.5 2 340 19.8 Comfort STI 125 Indirect 125 0.75 0.5 256 14.9 2.2 Contract STI 150 Indirect 150 0.93 1 353 20.5 2 451 26.2 Comfort STI 150 Indirect ...

  • Ariston 41-116-07 - page 17

    17 MTS (GB) Limited suppor t the initiative . Within the information pack you will find a cop y of the logbook. It is impor tant that this is completed in the presence of your customer , they are sho wn how to use it, and it is signed by them. Please instruct y our customer that they m ust hav e their logbook with them whene ver the y contact a ser ...

  • Ariston 41-116-07 - page 18

    In order to access the inside of the boiler , it is necessary to unscrew the f astening scre ws “ A ” of the control panel located on the lower part of the panel itself. The control panel mov es downw ard and when pulled f orward rotates on two later al hinges. The panel sta ys in a semi-horizontal position, which allows access to the inner par ...

  • Ariston 41-116-07 - page 19

    19 The flue connector has two aper tures, readings can be taken f or the temper ature of the combustion b y-products and of the combustion air , as well as of the concentrations of O 2 and CO 2 , etc. . T o access these intak es it is necessar y to unscrew the front screw and remo v e the metal plate with sealing gasket. T o achie v e the best test ...

  • Ariston 41-116-07 - page 20

    The boiler is fitted with the f ollowing de vices (see section 4.2 f or ref erences). 1 - I GNITION F AILURE : This indicates ignition f ailure when a flame is not detected within 7 seconds of star ting an ignition sequence. The L.E.D . “ F ” will illuminate to signal the shutdown status . The system can be reset by pressing and releasing the b ...

  • Ariston 41-116-07 - page 21

    21 The boiler can be con verted to use either methane (natural) gas (G20) or LPG (G30 - G31) by an A uthorised Service Centre. The operations that must be perf ormed are the follo wing: 1 . Replace the jets on the main burner (see table in section 5); 2. Adjust the maximum and minimum ther mal capacity v alues f or the boiler (see table in section ...

  • Ariston 41-116-07 - page 22

    22 It is recommended that the follo wing inspections be carried out on the boiler at least once a year: 1 - Check the seals f or the w ater connections; replace any f aulty seals. 2 - Check the gas seals; replace any f aulty gas seals . 3 - Visual check of the entire unit. 4 - Visual check of the comb ustion process or analysis of comb ustion by- p ...

  • Ariston 41-116-07 - page 23

    23 ...

  • Ariston 41-116-07 - page 24

    Manuf acturer: Merloni T ermoSanitari SpA - Italy Commercial subsidiar y: MTS (GB) LIMITED MTS Building Hughenden A v enue High Wycombe Bucks HP13 5FT T elephone: (01494) 755600 F ax: (01494) 459775 Internet: http://www .mtsgb .ltd.uk E-mail: inf o@mtsgb .ltd.uk T echnical Service Hot Line: (01494) 539579 23 99 84 1549 000 - Stampa: bief fe RECANA ...

  • Ariston 41-116-07 - page 25

    Servicing Instructions T ype C Boilers G.C.N: 41-116-06 41-116-07 LEA VE THESE INSTRUCTIONS WITH THE END-USER Countr y of destination: GB ...

  • Ariston 41-116-07 - page 26

    2 1. SER VICING INSTR UCTIONS 1.1 R EPLACEMENT OF P AR TS 1.2 T O G AIN G ENERAL A CCESS - Removing the front panel - Removing the sealed chamber front co ver - Removing the side panels 1.3 A CCESS T O THE C OMBUSTION C HAMBER - Removing the comb ustion cov er - Removing the b urner and jets - Removing the electrodes - Removing the main heat e xcha ...

  • Ariston 41-116-07 - page 27

    2. The control panel mov es downw ard and when pulled f orward, rotates on two lateral hinges; the panel sta ys in a semi- horizontal position, which allows access to the inner parts of the boiler (F IG . 1.2); 3. In order to increase the manouvering space, it is possib le to raise the control panel and rotate it to a fully horizontal position (F I ...

  • Ariston 41-116-07 - page 28

    4 1.2.2 Removing the sealed c hamber front co ver 1. Remov e the screws “C” (F IG . 1.6); 2. Lift the sealed chamber front cov er from the locating pins (F IG . 1.7). F IG . 1.6 C C F IG . 1.7 1.2.3 Removing the side panels 1. Remov e the f our screws “D” for each side panel (F IG .1.8); 2. Pull the panel aw a y from the boiler at the base, ...

  • Ariston 41-116-07 - page 29

    1.3.3 Removing the electr odes Bef ore carr ying out this procedure, unscre w and slide the burner forw ard (see pre vious section). 1. Remov e rubber gasket “G” (F IG . 1.12); 2. T o remove the detection electrode disconnect the cab le at its connection point close to the P .C.B . (F IG . 1.13); F IG . 1.12 G F IG . 1.13 1.3.2 Removing the b u ...

  • Ariston 41-116-07 - page 30

    6 3. Remov e scre w “H” ( F IG . 1.14); 4. Gently slide the electrode downw ard (F IG . 1.15) . T o replace, repeat the steps in rev erse order , paying par ticular attention to the follo wing: a - Centre the electrode in the positioning hole carefully , otherwise the electrode ma y break; b - Ensure that the left hand and right hand electrodes ...

  • Ariston 41-116-07 - page 31

    1. Disconnect electrical connections “N” and silicon pipe “O” (F IG .1.22); 2. Remov e scre w “P” and remov e the f an collar clamp “Q” (F IG .1.23); 3. Remov e scre ws “R” (F IG .1.24); 4. Remov e f an and mounting plate (F IG .1.25). 1.3.6 Removing the fan 1. Disconnect the electrical connections “K” and silicone pipes “ ...

  • Ariston 41-116-07 - page 32

    8 1.4 S ER VICING AND R EMO V AL OF THE G AS V AL VE 1.4.1 Setting the gas pressures 1 2 3 4 A B C F G D Setting the minimum and the maxim um power of the boiler 1. Check that the supply pressure to the gas v alv e is a minimum of 20 mbar f or natural gas. T urn off the gas supply at the isolation point under the boiler 2. T o do this, slack en the ...

  • Ariston 41-116-07 - page 33

    9 GAS BURNER PRESSURE OPERA TING POWER Regulating the heating power f or natural gas (G20) GAS BURNER PRESSURE OPERA TING POWER Regulating the heating power f or butane gas (G30) GAS BURNER PRESSURE OPERA TING POWER Regulating the heating power f or propane gas (G31) 21 RFFI 28 RFFI 2.4 20 8.5 3.3 0.7 1.7 1.05 3.15 1.26 11 1.6 84.7 111.1 1.78 1.76 ...

  • Ariston 41-116-07 - page 34

    10 F IG . 1.28 F IG . 1.29 F IG . 1.30 U V V 1.4.3 Removing the gas v alve Impor tant! Before removing the gas v alv e , ensure the gas supply is tur ned off . 1. Disconnect all the cables from the solenoid and modureg; 2. Remov e the spark generator (see pre vious section); 3. Release the top nut “ U ” (F IG . 1.28); 4. Remov e the scre ws “ ...

  • Ariston 41-116-07 - page 35

    11 1. 5. 2 Removing the safety v alve 1. Loosen nut “ Y ” (F IG . 1.33); 2. Disconnect the discharge pipe work from below the boiler ; 3. Unscrew and remo v e the valv e . 1.5.3 Removing the automatic air vent 1. Unscrew v alv e top “ Z ” (F IG . 1.34); 2. Remov e v alv e complete with float (F IG 1.35). F IG . 1.33 F IG . 1.34 Y Z F IG . 1 ...

  • Ariston 41-116-07 - page 36

    12 1.5.4 Removing the pump 1. Remov e the U-clips “ A1 ” and “ B1 ” (F IG . 1.36); 2. Remov e the retaining clip “ C1 ” (F IG . 1.37); 3. Release the nut “ D1 ” (F IG . 1.38); 4. Remov e the pipe “ E1 ” (F IG . 1.39); 5. Remov e the scre w “ F1 ” (F IG . 1.40); 6. Remov e the pump (F IG . 1.41). F IG .1 . 3 7 F IG .1 . 3 6 F ...

  • Ariston 41-116-07 - page 37

    13 1.5.6 Removing the e xpansion vessel 1. Release nuts “ H1 ” and remov e the gas pipe (F IG . 1.44); 2. Release nut “ I1 ” (F IG . 1.45); 3. Remov e loc k-nut “ J1 ” (F IG . 1.46); 4. Remov e the e xpansion v essel (F IG . 1.47). 1.5.5 Removing the pressure gauge 1. Remov e the U-clip “ G1 ” and remov e the pressure gauge coupling ...

  • Ariston 41-116-07 - page 38

    14 1.5.6 Removing the o verheat thermostat 1. Disconnect the ov erheat thermostat electr ical connections “ K1 ” (F IG . 1.48); 2. Then remov e the thermostat from its mounting by releasing the securing clip (F IG . 1.49). 1.5.7 Removing the fr ost thermostat 1. Disconnect the frost thermostat electr ical connection “ L1 ” (F IG . 1.50); 2. ...

  • Ariston 41-116-07 - page 39

    15 1.6.2 Removing the P .C.B.s 1. Isolate electricity; 2. Remov e the scre ws “ O1 ” (F IG . 1.56); 3. Separate the f acia panel from the rear of the control panel; 4. Unplug all electrical connections from the P .C .B. and remov e the scre ws “ P1 ” and remov e the P .C.B . (F IG . 1.57). F IG . 1.56 O1 O1 O1 O1 O1 P1 P1 P1 P1 O1 F IG . 1. ...

  • Ariston 41-116-07 - page 40

    16 B063 2. F A UL T FINDING P RELIMINAR Y CHECKS MAKE SURE THA T : IS THE SUPPL Y L.E.D. ILLUMINATED? IS THE L.E.D. ILLUMINA TED? NO NO NO YES NO 1 - C HECK THE FUSES 2 - C HECK THERE IS POWER SUPPLIED TO THE P .C.B. S 3 - C HECK / REPLACE THE P. C . B . (CT1) 1 - C HECK THE INTEGRITY OF THE L.E.D. 2-C HECK / REPLACE THE P .C.B. (CT1) P RESS THE ON ...

  • Ariston 41-116-07 - page 41

    17 B063 IS THE PUMP RUNNING? NO YES PO WER T O THE PUMP? 1 - C HECK THE OPERA TION OF THE PUMP 2 - R ELEASE /R EPLACE THE PUMP 1 - C HECK THE PUMP CABLE 2- C HECK /R EPLA CE P. C . B . (CT1) 3 - C HECK THE SYSTEM PRESSURE GA UGE IS A T 1.5 BAR A IS THE F AN RUNNING? BOILER SHUTDO WN? PO WER T O THE F AN? NO YES YES NO YES NO NO YES 1 - C HECK /R EP ...

  • Ariston 41-116-07 - page 42

    18 B063 IS THE BURNER ALIGHT? YES NO YES YES BOILER WORKING? YES NO NO NO NO YES 5- C HECK /R EPLACE P . C . B . (CBM2) 4-C HECK /R EPLACE P .C .B. (CBM2) 4 - C HECK /R EPLA CE P .C.B . (CBM2) 1 - C HECK /R EPLACE IGNITION ELECTRODES 2 - C HECK THE CABLES 3 - C HECK SP ARK GENERA TOR 4 - C HECK IGNITION ELECTRODE CABLES 1 - C HECK POWER SUPPL Y TO ...

  • Ariston 41-116-07 - page 43

    19 B063 3. ELECTRICAL DIA GRAMS SE011A L EGEND : A - On/Off Switch B - On/Off L.E.D . C - Heating Switch D - Heating L.E.D . E - Reset Button F - Ignition F ailure (Loc k out) L.E.D . A01 - Pump Pressure Switch A02 - F rost Ther mostat A03 - Modulator A04 - Circulation Pump A05 - Regulation Thermostat A06 - Exter nal Control System A07 - Time Cloc ...

  • Ariston 41-116-07 - page 44

    20 B063 SF008A ...

  • Ariston 41-116-07 - page 45

    21 B063 21/28 RFFI 354 353 352 351 33 63 61 9 10 11 12 7 4 3 2 60 62 1 11 12 11 11 65 67 68 69 64 11 72 104 100 97 99 98 77 79 80 81 101 80 106 107 105 103 75 76 102 13 64 66 11 64 64 82 59 89 74 13 24 30 31 32 37 38 13 19 20 16 14 17 15 58 57 56 55 54 53 49 41 43 47 48 46 45 44 50 42 13 94 21 23 22 19 301 302 303 304 38 38 39 93 47 29 85 51 52 96 ...

  • Ariston 41-116-07 - page 46

    22 B063 998616 573521 573520 570760 998612 573528 998447 569390 998627 999542 574279 999475 998809 999476 998424 998836 999091 999577 999499 999245 998517 998484 571651 997182 998943 998489 999894 998620 998893 999538 998618 998669 998887 998939 998433 998434 999501 950030 998623 998622 998624 998644 998643 998738 998961 999207 998716 998717 Key no ...

  • Ariston 41-116-07 - page 47

    23 B063 NO TES ...

  • Ariston 41-116-07 - page 48

    23 99 84 1550 000 - Manuf acturer: Merloni T ermoSanitari SpA - Italy Commercial subsidiar y: MTS (GB) LIMITED MTS Building Hughenden A v enue High Wycombe Bucks HP13 5FT T elephone: (01494) 755600 F ax: (01494) 459775 Inter net: http://www .mtsgb .ltd.uk E-mail: inf o@mtsgb .ltd.uk T echnical Service Hot Line: (01494) 539579 ...

メーカー Ariston カテゴリー Boiler

Ariston 41-116-07のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 41-116-07の取扱説明書
- Aristonの製品カード
- パンフレット
- またはAriston 41-116-07の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Ariston 41-116-07の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Ariston 41-116-07の取り付け説明書、サービスマニュアル、簡易説明書、またはAriston 41-116-07のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Ariston 41-116-07の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Ariston 41-116-07デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAriston 41-116-07を使用するのを助ける技術的文書のことです。説明書は通常、全てのAriston 41-116-07ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Aristonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Ariston 41-116-07の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAriston 41-116-07の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Ariston 41-116-07に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Ariston 41-116-07デバイスの基本機能を使うにあたってのヒント。 Ariston 41-116-07のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Ariston 41-116-07に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAriston 41-116-07のメーカー/サービスへの連絡先に関する情報。

Ariston 41-116-07についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAriston 41-116-07の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAriston 41-116-07で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)