Omega LV800の取扱説明書

12ページ 0.33 mb
ダウンロード

ページに移動 of 12

Summary
  • Omega LV800 - page 1

    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info L V800 SERIES Capacitance Point Level Sensors Shop online at U ser ’ s Guide ...

  • Omega LV800 - page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canad ...

  • Omega LV800 - page 3

    This manual contains the information necessary to ensure a safe and successful installation. Please read and comply with the section on page 9 of this manual pertaining to SAFETY . Doing so will ensure proper oper- ation of the equipment and the safety of all personnel. Before discarding shipping container , please inspect it thoroughly and verify ...

  • Omega LV800 - page 4

    PRE-INST ALLA TION CONSIDERA TIONS 3 Choosing a Location: (See Figure 2) 1) Material Flow - When selecting a location for the LV800, choose a point in the vessel where the probe will be out of the direct flow of incoming and outgoing material to prevent any mechanical damage that may be caused by the pres- sure of the flow. The LV800 must be positi ...

  • Omega LV800 - page 5

    4 MECHANICAL INST ALLA TION Standard, Food Grade and Stub Probe Mounting: (See Figures 3 & 4) 1) Select a mounting location in accordance with the Pre- Installation Recommendations. 2) If using a welded fitting, cut a hole into the side/top of the vessel corresponding to the mounting connection (1-1/4” NPT or 3/4” NPT). If using a mounting ...

  • Omega LV800 - page 6

    5 Figure 5 Power Input: (See Figure5) The LV800 is designed to accept either 115VAC or 230VAC (factory set). Verify the intended voltage supply is compatible with the voltage configuration indicated on the electronics and the external nameplate. Connect power as shown in Figure 5. Select wire size that can deliver suitable voltage and current for t ...

  • Omega LV800 - page 7

    6 Delay: A potentiometer is provided for setting the time delay between the time material is "sensed" (Yellow LED on) and the time the relay contact output changes (Red LED on). Units have a 1- turn potentiometer. A clockwise rotation will increase the delay from .25 to 15 seconds. This adjustment minimizes false sig- nals associated with ...

  • Omega LV800 - page 8

    TROUBLESHOOTING MAINTENANCE PROBLEM: Sensor will not sense material CAUSE/SOLUTION: 1) Verify power is applied to the sensor. 2) Verify "Sense Adjust." Reposition adjustment clockwise therefore making the probe more sensitive to "difficult to sense" materials. 3) Verify probe coverage when sensing is expected. The sen- sor is no ...

  • Omega LV800 - page 9

    8 MECHANICALS Standard Probe Stub Probe DIMENSIONS ARE SHOWN IN INCHES WITH MILLIMETER EQUIVALENT IN BRACKETS ...

  • Omega LV800 - page 10

    SPECIFICA TIONS SAFETY Power: 115VAC ( ± 15%); 2.5VA; 50/60Hz / 230VAC ( ± 15%); 2.5VA; 50/60Hz Altitude: 6562 ft (2000 m) max Installation Category: II Pollution Degree: 4 (Reduced to 2 by enclosure) Suitable for indoor/outdoor use Ambient Op Temp: -40˚ F (-40˚ C) to +150˚ F (+65˚ C) * Internal Bin Temp: To +176˚ F (+80˚ C) w/alum. mount ( ...

  • Omega LV800 - page 11

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months fro m da te o f pur chas e. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s ...

  • Omega LV800 - page 12

    M-4168/0405 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers & Pr ...

メーカー Omega カテゴリー Stud Sensor

Omega LV800のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LV800の取扱説明書
- Omegaの製品カード
- パンフレット
- またはOmega LV800の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega LV800の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega LV800の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega LV800のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega LV800の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega LV800デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega LV800を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega LV800ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omegaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega LV800の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega LV800の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega LV800に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega LV800デバイスの基本機能を使うにあたってのヒント。 Omega LV800のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega LV800に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega LV800のメーカー/サービスへの連絡先に関する情報。

Omega LV800についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega LV800の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega LV800で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)