    #L010068 #L010068 USER'S GUIDE MODEL MDM40001 MICROSTEP DRIVER ANAHEIM AUTOMATION 910 E. Orangefair Lane Anaheim, CA 92801 TEL (714) 992-6990 FAX (714) 992-0471 E-Mail: aamotion@aol.com COPYRIGHT Copyright 19 96 by Anaheim Automation. All rights reserved. No part of thi s publication ma y be reproduced, transmitted, transcribed, stored in a re ...

  • Anaheim MDM40001 - page 2

    #L010068 #L010068 1 2 TABLE OF CONTENTS INTRODUCTION PAGE INTRODUCTION ......................................... 2 ORDERING INFORMATION ................................ 3 DESCRIPTION .......................................... 4 DRIVER TERMINAL DESCRIPTION P1 ............... 4 DRIVER TERMINAL DESCRIPTION P2 ............... 5 WIRING DIAGRAM ......... ...

  • Anaheim MDM40001 - page 3

    #L010068 #L010068 3 4 4 Amp Microstep Driver MDM40001 (This Manual) 6 Amp Microstep Driver MDM60001 10 Amp Microstep Driver MDM10001 40VDC Power Supply PSA40V4A 65VDC Power Supply PSA65V5A 80VDC Power Supply PSA80V4A Shielded Motor Cable AA129010S ORDERING INFORMATION FOR ANAHEIM AUTOMATION PIN DESCRIPTIONS P1 MICROSTEP DRIVERS AND ACCESSORIES MDM4 ...

  • Anaheim MDM40001 - page 4

    #L010068 #L010068 5 6 PIN DESCRIPTIONS P2 TYPICAL HOOK-UPS FOR APPLICATION : Pin# Description 1 Reduction Adjust: Phase Current Reduction Input. A resistor between this pin and pin 2 (Connector P2, Current Adjust) will proportionately reduced the current in both windings (1 second after the last positive going edge of the step clock input). The amo ...

  • Anaheim MDM40001 - page 5

    #L010068 #L010068 7 8 SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS INPUT VOLTAGE +12 TO +48 VDC OUTPUT CURRENT 4 AMPS PEAK PLATE TEMPERATURE 70° C STORAGE TEMPERATURE 40° TO +125° C INPUT CURRENT (PINS 1, 2, 4, 5) 15 mA Max ELECTRICAL SPECIFICATIONS (TA=25 E E C, V+ = 40VDC) ITEM TEST MIN TYP MAX UNI CONDITION TS Input Voltage 12 24 40 V Phase Output ...

  • Anaheim MDM40001 - page 6

    #L010068 #L010068 9 10 DETERMINING OUTPUT CURRENT Reducing the output current in the MDM40001 can be accomplished by connecting an The output current for the motor used when mic rostepping is determined differently from automatical ly 1 second after the last positive going edge of the step clock input. Se e that of a half/full unipolar driver. In t ...

  • Anaheim MDM40001 - page 7

    #L010068 #L010068 11 12 STEP MOTOR CONFIGURATIONS 4 Lead Motors Step motors can be configured as 4, 6, or 8 leads. Each configuration requires different currents. Shown below are different lea d configurations and the procedures to determine their output current. 6 Lead Motors When configur ing a 6 lead motor in a half-coil configuration (connected ...

  • Anaheim MDM40001 - page 8

    #L010068 #L010068 13 14 CONNECTING THE STEP MOTOR Phase 1&3 of the Step Motor is connected between pins 7 and 8 on connector P2. Phase 2&4 of the Step Motor is connected between pins 5 and 6 on connector P2. Refer to Figure 1 for TYPICAL APPLICATION HOOK-UP NOT E : The physical direction of the motor with respect to the direction input wil ...

  • Anaheim MDM40001 - page 9

    #L010068 #L010068 15 16 MICROSTEP SELECTION FULLSTEP OUTPUT SIGNAL The number of microsteps per step is selected by switches 1, 2, 3, and 4 of the DI P The MDM40001 has an active LOW open drain output at Connector P1, Pin 7 labeled switch. Table 5 shows the standard resolution values along with the associated inputs ON F/S OUT. This o utput is TRUE ...

  • Anaheim MDM40001 - page 10

    #L010068 #L010068 17 18 TIMING FAULT PROTECTION The Direction and Microstep Resolu tion Select inputs are synchronized with the positive The MDM40001 is internally protected against over temperature and short circuits. going edge of the Step Clock inpu t. When the Step Clock input goes high, the Direction The over tem perature set point is between ...

  • Anaheim MDM40001 - page 11

    #L010068 #L010068 19 TORQUE/SPEED CURVES TORQUE/SPEED CURVES ...

メーカー Anaheim カテゴリー Home Theater Server

Anaheim MDM40001のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MDM40001の取扱説明書
- Anaheimの製品カード
- パンフレット
- またはAnaheim MDM40001の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Anaheim MDM40001の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Anaheim MDM40001の取り付け説明書、サービスマニュアル、簡易説明書、またはAnaheim MDM40001のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Anaheim MDM40001の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Anaheim MDM40001デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAnaheim MDM40001を使用するのを助ける技術的文書のことです。説明書は通常、全てのAnaheim MDM40001ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Anaheimの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Anaheim MDM40001の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAnaheim MDM40001の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Anaheim MDM40001に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Anaheim MDM40001デバイスの基本機能を使うにあたってのヒント。 Anaheim MDM40001のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Anaheim MDM40001に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAnaheim MDM40001のメーカー/サービスへの連絡先に関する情報。

Anaheim MDM40001についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAnaheim MDM40001の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAnaheim MDM40001で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)