Omega FTB500の取扱説明書

28ページ 0.83 mb
ダウンロード

ページに移動 of 28

Summary
  • Omega FTB500 - page 1

    Manual OPerator’ s (i%%i Flowrate Meters Low a Q FTBSOO Series @a ...

  • Omega FTB500 - page 2

    DFMOSSSFVRIBA 359-RUSH ti Environmental Monitoring and Control Call for Your FREE Handbook Request Form Today: (203) V Electric Heaters V Data Acquisition Systems andconductivity pH W V Flow and Level & Force V Pressure, Strain 1c Temperature & Encyc l oped i as 6TU, England Telephone: 44 (1455) 285520 FAX: 44 (1455) 283912 The OMEGA Co m p ...

  • Omega FTB500 - page 3

    .21 . 20 SECTION 8 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . 20 SECTION 7 ACCESSORIES . . . . . . . . . . .I 8 SECTION 6 RECOMMENDED SPARE PARTS LIST . . . . . a . 15 I5 SECTION 5 TROUBLESHOOTING AND MAINTENANCE . . . . . . . . . . . FTBSOO Flowmeter (Ball Bearing Design) . Se ...

  • Omega FTB500 - page 4

    503,4 for 504, or 5 for 505. 1 X 1 for 501, 2 for 502, 3 for tistokesl of your liquid. The maximum is 25CK. cen- (“CK) in part number with the viscosity (in * Replace NOTE FTB50_X-t*CK)-5KP PSIG FTB5O_X-(*CK)-115VAC 5000 115VAC signal conditioner power supply FTB50_X-t”CKb5VDC FTB50_X-(*CK)-P 0-5VDC output TTL Pulse output FTB505-(“CK) ‘ CK ...

  • Omega FTB500 - page 5

    AMP. Figure l-l. Block Diagram The basic operation of the system is as follows: The frequency signal from the flowmeter is connected to the FTB500 with a twisted pair shielded cable. The signal enters through the SENSITIVITY control which is used to reject unwanted noise by raising the trigger threshold above the background noise present. The low l ...

  • Omega FTB500 - page 6

    FTB500 Series of meters establish a linear response after an initial offset correction when operating at a constant viscosity. 3 FTBSOO flowmeter are shown in Figures l-2 and 1-3. The pelton rotor causing it to rotate The motion of the rotor is sensed by the pickup coil and converted to a pulsing output signal where the frequency is related to the ...

  • Omega FTB500 - page 7

    FTBIOO Calibration Curve 4 FLOWRATE Figure 1-3. Normalized % OF MAX I MUM .80 10 50 100 I_7 f 1.00 7 ! UNLINEARIZED 5 90 8 u FTBSOO Output Characterlstlcs Diagram LINEARIZED (GPM) Figure 1-2. / UN LINEARIZED OUTPUT FLOW RATE lL ...

  • Omega FTB500 - page 8

    H,O is the pressure drop from Figure l-4 Figure 14. Gross Pressure Drop Characteristic Curve on Water 5 PSID SpGr is the specific gravity H,O where: Cpse is viscosity in centipoise PSID (SpGr)” x (Cpsel” x PSID = flowrate and the fluids viscosity and density. FTB500 Series Turbine Meter given the pressure drop on water at the maximum FTB500 Ser ...

  • Omega FTB500 - page 9

    NOTE The carrier will not honor any claims unless all shipping material is saved for their examination. After examining and removing con- tents, save packing material and carton in the event reshipment is necessary. *l% of reading. In some applications, the fluid viscosity is a known function of temperature A PC could be used to eliminate the other ...

  • Omega FTB500 - page 10

    7 - 2-I. Typical Turbine Meter Installation METER RUN V3 = BYPASS VALVE S = STRAINER FS = FLOW STRAIGHTENER TFM = TURBINE FLOWMETER Figure Vl, V2 = BLOCKING VALVE v2 t TFM I FS 2.5V. Slowly turn the SENSITIVITY threshold control counter-clockwise until in- dication stops. 2.3 GENERAL Proper application of the turbine flowmeter requires a suitable p ...

  • Omega FTB500 - page 11

    pickoff device. BYPASS RUN -A properly sized bypass run with suitable blocking valves may be equipped where an interruption in fluid flow for turbine meters ser- vicing can not be tolerated. STRAINER-A strainer, filter and/or air eliminator is recommended to reduce the potential of fouling or damage Recommended mesh size is at least 100 microns. Fi ...

  • Omega FTB500 - page 12

    ” I.D. CONDUIT Figure 2-2. Mounting Holes Location Diagram 9 H NPT FOR 35/4” Tl=t.aJ / - a--+------_, 115VAC (optional) for appropriate terminals for installation. Connect the flowmeter cable to the FTB500 including shield. “0” RING REMOVABLE COVER FTB500 should be placed in a convenient location with sufficient room for easy opening of the ...

  • Omega FTB500 - page 13

    Wiring Diagram 10 EQUlPPED WITH AN INTEGRAL CALIBRATION SIGNAL. TO INJECT THIS TEST SIGNAL, INSTALL A JUMPER FROM TERMINAL 8 TO TERMINAL 1. Figure 2-3. DC Input Installation FTB500 IS NOTE THE - DC VOLTAGE INPUT TERMINAL BLOCK 2 1234567 8 @ F(TEBT) 0 1-P OPTION) COMMON @ _ 0 + SIGNAL PULSE OUTPUT - RETURN @ TERMINAL ANALOG OUTPUT BLOCK 1 (STANDARD) ...

  • Omega FTB500 - page 14

    115VAC Input Installation Wiring Diagram 11 NOTE Figure 24. TlON SIGNAL. TO INJECT THIS TEST INSTALL A JUMPER FROM TERMINAL FTB500 IS EQUIPPED WITH AN INTEGRAL CALIBRE SIGNAL, 8 TO TERMINAL 1. THE (NEUTRALS TERMINAL BLOCK 1 TERMINAL BLOCK 2 E u @ F(TEST) IIBVAC 50160 Hz INPUT Ayy==+--~ Xl PICKUP COIL ...

  • Omega FTB500 - page 15

    FfOSl is the offset frequency 12 FfTEST) is the test frequency FfOUTl is the output frequency of the linearizer F(OS)l where: [F(TEST) + F(OUT) = 1.8 2-41, injects an internally generated frequency. When using this feature, F (TEST) is equal to 120 Hz. jumpered to the input terminal (connecting Terminal 8 to Terminal 1, refer to Figure 2-3 or [F(OS ...

  • Omega FTB500 - page 16

    (OS)1 13 [F(MAXl + F ZERO (OS11 x SPAN + [F (TEST) + F 5mA, or OV Equation 3 Set (SPAN) = 4mA, F(GS) 60 Equation 2 Set (ZERO) = SET TO NO FLOW CONDITION i.e., F(MAX) = K FACTOR x R (MAX) _ 11, injects an internally generated frequency into the unit. When using this feature, F (TEST) is equal to 120 Hz and is used in the following equation. Alternat ...

  • Omega FTB500 - page 17

    Potentiometer locations 14 ’ Figure 3-1. Dimensions and * EQUIPPED FOR ANALOG OUTPUT OPTION mA output, OV for 0 to 5v output. 1. The Range Adjustment is accomplished by selecting a switch position on a DIP switch located on the PCA-112 printed circuit card depending on the model. Refer to Table 3-l to determine required switch position, and selec ...

  • Omega FTB500 - page 18

    FTBBOO FLOWMETER (BALL BEARING DESIGN) Preventative maintenance requires that the Mini Flowmeter under go a general inspection. Refer to Figure 4-I and the following procedure to remove the flowmeter internals from the housing. A clean work area is required. 15 Measurement_Systems are constructed to give a long ser- vice life. However, problems do ...

  • Omega FTB500 - page 19

    ROTOR WHEN LOOK I NG DOWN FROM TOP DETA I L OF ROTOR F i gure 4 -1. S tandard Ba ll Bear i ng Cu ta way D iagra m 16 WELO- CORRECT OR I ENTAT I ON OF FL OW -8 FL OW - ...

  • Omega FTB500 - page 20

    #77-545-018 or equivalent on the insert. NOTE “0” ring should be lightly lubricated with “0” ring lubrication wh ich is silicone based. 12. P lace insert on the shaft. W hen properly seated gently push the insert back on the shaft. 13. Install and tighten the threaded plug. Tighten plug until snug. Do not over tighten. The flow m eter is re ...

  • Omega FTB500 - page 21

    Wiring s PULSE 9 SCALING 10 11 12 Figure 5-1. Internal ; CONDITIONER ;$it;TIC % ; 9 10 11 12 2 FTBSOO 6 SIGNAL CONDITIONER I 2 3 4 11 .l 11 -1 11 COIL-1 0 GRN PCA-115 PCA-114 @ WHT @ . BLK I-II- ACIDC POWER SUPPLY ANALOG OUTPUT - I PCA-112 FiTESTi TO PICKUP COIL ANALOG OUPUT COMMON PULSE OUTPUT COMMON ...

  • Omega FTB500 - page 22

    (SENS) potentiometer clockwise 2. Replace pickup coil and/or interconnec- ting wiring. 3. Replace PCA-114. 4. Replace PCA-115. 5. Replace PCA-112. Unit gives pulse output with 1. Noise pickup, turn sensitivity adjust no flow present counter clockwise until correct zero flow indication is obtained. 2. Replace pickup coil. 3. Replace PCA-115. 4. Repl ...

  • Omega FTB500 - page 23

    FTB500-ADP 20 n MNPT adaptor kit with 10” upstream and 5” downstream straight SS tubing % w MS flare to % ‘ /4 SLO BLO SIGNAL CONDITIONER CARD (MAGNETIC PICKUP COIL) LINEARIZE AND FLOW DRIVE, PLUG-IN CARD FUSES, POWER SUPPLY I I 1 BOX SECTION 7 ACCESSORIES DESCRIPTION PART NUMBER QTY POWER SUPPLY/ANALOG OUTPUT CARD 1 PCA-II4 PCA-115 DESCRIRTI ...

  • Omega FTB500 - page 24

    <IO9 0.5 seconds for IO-90% 21 PPM/OC. o-5v. *200 *0.05% of full scale; IO-go%. Adjustable from 0.5 to 2 seconds. Output suitable for driving grounded or floating load types PPM/OC. 4 to 20mA into 375X max. 0.5 seconds for +200 +0.05% of full scale, PSIG optional 125 Hz nominal PSIG standard 5000 PSID 1000 *0.25% of reading IO + 1% of reading fo ...

  • Omega FTB500 - page 25

    mA). mA or 100 II MNPT adaptor kit optional A circuit protection device located inter- nally. Check main schematic for proper size and type. A single control used to set the threshold sensitivity level above the ambient noise pickup. An internal 20 turn adjustment on the PCA-II5 printed circuit card used to ad- just the equivalent offset frequency ...

  • Omega FTB500 - page 26

    O-100GPM). A multiple turn adjustment potentiometer which is used to dampen the response at the analog output. A dual-in-line (DIP) switch located on the PCA-112 board which is used to select the desired pulse output scaling factor. 23 1OV cor- responding to mA or 0 to mA equivalent flow range (i.e., 4 to 20 SPECIFICATIONS (Cont ’ d) SPAN: RESPON ...

  • Omega FTB500 - page 27

    0 Copyright 1995 OMEGA ENGINEERING, INC. All rights reserved. This documentation may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC. CALI_ the following information available BRATIDN, consult OMEGA for curr ...

  • Omega FTB500 - page 28

    /0992 & Dissolved Oxygen Instruments MO968 pH, Conductivity k!’ & Wastewater Treatment m Industrial Water m Air, Soil &Water Monitors & Tubing iZ!’ Pumps b? Refractometers & Control Instrumentation D Metering m Laboratory Heaters ENV IRONMENTAL MON ITORING AND CONTROL k? Flexible Heaters & Band Heaters m Immersion & ...

メーカー Omega カテゴリー Automobile Parts

Omega FTB500のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FTB500の取扱説明書
- Omegaの製品カード
- パンフレット
- またはOmega FTB500の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega FTB500の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega FTB500の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega FTB500のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega FTB500の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega FTB500デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega FTB500を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega FTB500ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omegaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega FTB500の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega FTB500の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega FTB500に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega FTB500デバイスの基本機能を使うにあたってのヒント。 Omega FTB500のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega FTB500に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega FTB500のメーカー/サービスへの連絡先に関する情報。

Omega FTB500についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega FTB500の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega FTB500で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)