General Dynamics LT-3600の取扱説明書

26ページ 0.38 mb
ダウンロード

ページに移動 of 26

Summary
  • General Dynamics LT-3600 - page 1

    CG-1309 REV C FEB 2006 OPERATION & MAINTE NANCE MANUAL UP/DN CONVERTER L-BAND LT-3600 SERIES 1915 Harrison Road Longview, Texas 75604 EXPORT CONTROL WARNING - Do not disclose this document or its contents to non-U.S. Persons, o r transmit this docum ent or its con tents outside th e United States without the written permission of Vertex Communi ...

  • General Dynamics LT-3600 - page 2

    Integrated L-Band Up/Dn Conve rter LT3600 CG-130 9 Page 2 WARRANTY VertexRSI warrants its products for a peri od of two (2) years from the date of shipment to be free from defects caused by faulty materials or poor workmanship. The terms and conditions of this warranty are as follows • The purchaser must notify VertexRSI pr omptly upon discovery ...

  • General Dynamics LT-3600 - page 3

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 3 TABLE OF CONTENTS Section 1 General Information ................................................................................................ 6 1.0 Introduction ............................................................................................................... ............... ...

  • General Dynamics LT-3600 - page 4

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 4 Section 4 Serial Command Set .............................................................................................. 20 4.0 General .................................................................................................................................... 20 4.1 LT-3600 Seria ...

  • General Dynamics LT-3600 - page 5

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 5 APPENDICES A Technical Manual Revision History ....................................................................................... 26 B CCA Software Revision History ............................................................................................. 26 C Display Panel Softwa re ...

  • General Dynamics LT-3600 - page 6

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 6 SECTION 1 General Information 1.0 INTRODUCTION This manual contains installation, operation, and maintenance information for th e Integrated L-Band Up/Dn Converter manufactured by VertexRSI, Longview, Tx. Information is organized according to section. Within each section the pages, figures a ...

  • General Dynamics LT-3600 - page 7

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 7 1.4 SPECIFICATIONS The specifications for the Integrated L-Band Up/Dn Converter are listed in Table 1-1, along with the mechanical dimensions. 1.5 FRONT PANEL All the operating controls and indicators for the Integrated L-Band Up/Dn Converter are located on the front panel. The front panel i ...

  • General Dynamics LT-3600 - page 8

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 8 1.8 Part Number Configuration The Part Number Selection Chart shows configurati on options that are set at the factory prior to shipment. The voltage output to J4 and J10 may be changed as required by the customer, however this requires removal of the cove r and resetting internal jum per co ...

  • General Dynamics LT-3600 - page 9

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 9 Table 1-1 Integrated L-Band Specifications UPCONVERTER Input Frequency Range 50 to 90 MHz Input Impedance 50 Ohms Input Level Range -20 to -40 dBm Output Frequency Range 950 to 1525 MHz 950 to 1950 MHz (Optional) Output Impedance 50 Ohms Output Return Loss 18dB Conversion Gain 10 to 30 dB (0 ...

  • General Dynamics LT-3600 - page 10

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 10 Table 1-1 Integrated L-Band Specifications OPTIONAL INTERNA L REFERENCE Reference Frequency 10.000 MHz Stability (0 to +50 °C) + 2 x 10 -8 Aging per Day + 1 x 10 -9 Output Level (rear panel) + 12 dBm + 2 dB Phase Noise @ 10 Hz -115 dBc/Hz 1 00 Hz -135 dBc/Hz 1 kHz -145 dBc/Hz 1 0 kHz < ...

  • General Dynamics LT-3600 - page 11

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 11 Table 1-1 Integrated L-Band Specifications INTERFACE AND CONNECT ORS Voltage (auto-ranging) 115/230 VAC + 15% Internal Electronics (Power) 25 watts StarSwitch Interface Connectors (Options) DB-15 (Female) Remote Serial Interface: Standard: RS-422/RS-485 (J7) DB-9 (Male) External SSPB Monito ...

  • General Dynamics LT-3600 - page 12

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 12 SECTION 2 Installation 2.0 INTRODUCTION This section defines th e installation require- ments by which the Integrated L-Band Up/Dn Converter will meet the published specifications. 2.1 UNPACKING AND INSPE CTION Remove the unit from its shipping container and inspect for any damage sustained ...

  • General Dynamics LT-3600 - page 13

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 13 2.4.6 External 10 MHz Input (J2) This connector is a BNC female. The male mate (not supplied) should be compatible with the 50-ohm coax used to connect to the system. 2.4.7 SSPB Interface (J6) This connector is a 9-pi n female miniature type “D” connector with standard #4-40 female scre ...

  • General Dynamics LT-3600 - page 14

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 14 SECTION 3 Operation 3.0 INTRODUCTION The Up/Down Converter can be controlled from the front panel or remotely via a serial bus located on the rear panel of the converter. Various menus are available for EDIT and DISPLAY purposes. See Figure 3-2 for a listing of the menus. Section 4 gives a ...

  • General Dynamics LT-3600 - page 15

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 15 Figure 3-2 Menu Listing RefOsc: OK Ofst:127 Slope Factor: 0 dB Unit Address: xx xx = 422 Mode Brd SN 1234 20/12/04 S/W:v7.70 Temp: 32 C Front Panel SW v 5.20 FP Alarm Tone: On UC 1200.000 +25.0 dB DC 1300.000 +35.0 dB UC: Ovr State: On DC: Low State: Muted UC Lvl: +1 dBm DC Lvl: -25 dBm SSP ...

  • General Dynamics LT-3600 - page 16

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 16 Figure 3-3 Satellite Memory UC 0950.000 +10.0 dB DC 1525.000 +30.0 dB HIT ANY KEY (0-9) Example (KEY 0) EDIT ENT ENTER KEY RECALLS MEMORY TO ACTIVE UC0 1200.000 +20.0 dB DC0 1200.000 +30.0 dB ESCAPES TO ADJACENT MENU WITHOUT RECALL CONFIRM AND STORE CHANGE TO EACH FIELD AND LEAVE EDIT MODE ...

  • General Dynamics LT-3600 - page 17

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 17 3.1 StarSwitch Operation The LT3600 UP/DOWN Converter may be used in conjunction with the StarSwitch to provide redundancy switch over operations if configured as StarSwitch Ready. The following modes of operation may be selected. 3.1.1 Auto Mode Upon reaching the StarSwitch Menu the inform ...

  • General Dynamics LT-3600 - page 18

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 18 3.1.4 Backup Converter Operation The Backup Converter must be programmed to store all of the Converter Fre quencies and Gains in the system, in its Satellite Memory Locations, correspondi ng to the Converter Num ber (1 to 8) labeled on the StarSwitch Interface cables. Figure 3-7 show s the ...

  • General Dynamics LT-3600 - page 19

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 19 3.2 Front Panel Alarm Settings Menu Page Acti ve Modes Mask (Default) Comment 1) Starswitch Auto ON STBY Auto Must select "Auto" Mode when Starswitch is not present. Forces summary alarm to OFF (see Stars witch operation). Forces summary alarm to ON (see Sta rswitch operation). 2) ...

  • General Dynamics LT-3600 - page 20

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 20 SECTION 4 Serial Command Set 4.0 GENERAL The standard Up/Dn Converter is controlled via a rear panel seri al link (RS-422/485)(Reconfigurable to RS-232). With the front panel control, a user can operate the L-Band Up/Dn Converter from its front panel as well as from the serial link. This se ...

  • General Dynamics LT-3600 - page 21

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 21 4.3 COMMANDS 4.3.1 Set UP/Converter Frequency {aaC1xxxxx} Where xxxx(x) = First 4 numeric data characters Range: 0950 to 1525 (MHz) for Std. Band units Range: 0950 to 1950 (MHz) for Extended Band units Where (xxxx)x = Fifth character is fractional MHz as follows 0 = 0.0 MHz 1 = +0.125 MHz 2 ...

  • General Dynamics LT-3600 - page 22

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 22 4.3.7 DOWN/Converter (LNB) Spectrum Control {aaC7x} Where x = 0 for Non-Inverting spectrum and x = 1 for Inverting spectrum 4.3.8 UP/Converter Spectrum Control {aaC7TXz} Where z = 0 for Non-Inverting spectrum and z = 1 for Inverting spectrum 4.3.9 SSPB Band Control {aaC8x} Where x = 0 for S ...

  • General Dynamics LT-3600 - page 23

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 23 4.4 STATUS REQUESTS 4.4.1 Command Status {aaS1} Returns: {aaS1bbbbccccddddeeeefffUL} Where bbbb = Up/Converter Frequency (as above) cccc = Down/Converter Frequency (as above) dddd = Up/Converter Gain eeee = Down/Converter Gain fff = Ref. Osc. Offset U = 0 for Non-Inverting Up/Converter, 1 f ...

  • General Dynamics LT-3600 - page 24

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 24 4.4.4 L-Band Status {aaS3} Returns: {S3bbCddTReeN} Where: bb = 2 Chars., LNB current Detection Range: 00 to 99 ( 0 - 990 mA) C = 1 Character, SSPB Band Control Range: 0 = low band, 1 = high band dd = 2 Characters, SSPB Gain Range: –8 to –0 or ++ (dB) ++ = Full On T = 1 Character, Up/Con ...

  • General Dynamics LT-3600 - page 25

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 25 4.4.9 Query Card Type {aaZ} Returns: {aaZxx} Where: xx = L-Band Card Type (1 – 8) 10 = 70 MHz IF, Std. Band Unit (SBU) 20 = 140 MHz IF, SBU 11 = 70 MHz IF, Ext Band Unit (EBU) 21 = 140 MHz IF, EBU 50 = 70 MHz IF, SBU with Inv. Up/Converter Spectrum 60 = 140 MHz IF, SBU with Inv. Up/Conver ...

  • General Dynamics LT-3600 - page 26

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 26 Appendix A Manual Revision Hist ory C – Add Starsw menu M. Neely 2-03-05 D. Snyder 2-03-05 6323 B – Add Satellite Menu Info M. Neel y 10-14-05 D. Snyder 10-5-05 6129 A – Gain signs M. Neely 8-15-05 D. Snyder 8-15-05 6020 - Original Release M. Neely 11-5-04 D. Snyder 11-5-04 5442 Rev. ...

メーカー General Dynamics カテゴリー Network Hardware

General Dynamics LT-3600のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LT-3600の取扱説明書
- General Dynamicsの製品カード
- パンフレット
- またはGeneral Dynamics LT-3600の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、General Dynamics LT-3600の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、General Dynamics LT-3600の取り付け説明書、サービスマニュアル、簡易説明書、またはGeneral Dynamics LT-3600のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、General Dynamics LT-3600の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

General Dynamics LT-3600デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGeneral Dynamics LT-3600を使用するのを助ける技術的文書のことです。説明書は通常、全てのGeneral Dynamics LT-3600ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

General Dynamicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. General Dynamics LT-3600の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGeneral Dynamics LT-3600の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。General Dynamics LT-3600に関してこのドキュメントで見つけることができる全てのヒントの目次
3. General Dynamics LT-3600デバイスの基本機能を使うにあたってのヒント。 General Dynamics LT-3600のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。General Dynamics LT-3600に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGeneral Dynamics LT-3600のメーカー/サービスへの連絡先に関する情報。

General Dynamics LT-3600についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGeneral Dynamics LT-3600の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGeneral Dynamics LT-3600で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)