York AHE18 THRU 60'の取扱説明書

14ページ 0.25 mb
ダウンロード

ページに移動 of 14

Summary
  • York AHE18 THRU 60' - page 1

    TECHNICAL GUIDE SINGLE PIECE ST ANDARD ECM AIR HANDLERS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T PUMPS MODELS: AHE18 THRU 60* Due to continuous p roduct improvement, specifications are subject to change without notice . Visit us on the web at: www .york.com Additional rating informatio n can be found at: www .ahridirectory .org WARRANTY S t a ...

  • York AHE18 THRU 60' - page 2

    2 Johnson Controls Unitary Products 680210-YTG-B-03 11 DIMENSIONS & DUCT CONNECTION DIMENSIONS J D Blower Compartment Circuit Breaker Panel Drain Pan Connections for Horizontal Applications Refrigerant Connections Drain Connections for Upflow Applications 7-1 1/32” B A K C 1-1/2” T op Outlet Dimensions Filter Access 18-9/32” E Bottom Inle ...

  • York AHE18 THRU 60' - page 3

    Johnson Controls Unitary Pro ducts 3 680210-YTG-B-0311 COOLING CAP ACITY Models Rated CFM Entering Air °F (Dry/Wet Bulb) MBH@ Evaporator T emperature and Correspo nding Pressure °F/PSIG 35/61.5 40/68.5 45/76.0 50/84.0 FULL-CASED “A” TYPE MUL TI-P OSITION AHE18B3XH21 610 72 37.9 33.7 28.3 23.3 67 31.8 27.0 22.5 17.6 62 26.4 21.5 16.7 1 1.6 57 ...

  • York AHE18 THRU 60' - page 4

    4 Johnson Controls Unitary Products 680210-YTG-B-03 11 Note: Airflow is calculated for each system tonnage . Capacity varies with O.D. prod uct. AHE42D3XH21 820 72 56.6 51.1 42.8 35.6 67 48.6 41.1 34.8 27.6 62 39.4 33.0 26.0 18.3 57 30.5 26.6 23.1 19.6 1000 72 65.7 61.0 52.7 42.9 67 58.0 49.6 41.1 32.1 62 46.7 38.9 30.4 21.8 57 36.4 31.6 27.6 23.3 ...

  • York AHE18 THRU 60' - page 5

    Johnson Controls Unitary Pro ducts 5 680210-YTG-B-0311 APPLICA TION F A CTORS - RA TED CFM VS. ACTUAL CFM % Of Rated Airflow (CFM) 80% 90% 100% 1 10% 120% Capacity Factor 0.96 0.98 1.00 1.02 1.03 PHYSICAL & ELECTRICAL DA T A - COOLING ONL Y (60 Hz) Models AHE18B AHE24B AHE30B AHE36C AHE42D AHE48 D AHE60D Blower - Diameter x Width 10 x 8 10 x 8 ...

  • York AHE18 THRU 60' - page 6

    6 Johnson Controls Unitary Products 680210-YTG-B-03 11 ELECTRICAL DA T A - 208/230-1-60 Models Heater Models* Max. Static ECM Min. Speed T ap T otal Heat 1 kW S t aging kW MBH W1 Only W1 + W2 208V 230V 208V 230V 2 08V 230V 208V 230V AHE18B3XH21 6HK*6500206 0.3 Med Low #2 1.8 2.2 6.1 7. 5 1.8 2.2 1.8 2.2 6HK*6500506 0.3 Med Low #2 3.6 4.4 12.3 15.0 ...

  • York AHE18 THRU 60' - page 7

    Johnson Controls Unitary Pro ducts 7 680210-YTG-B-0311 ELECTRICAL DA T A - (FOR SI NGLE SOURCE POWER SUPPL Y) - COPPER WIRE - 208/230-1-60 Models Heater Models* Heater Amp s 240V Field Wiring Min. Circuit Amp acity Max. O.C.P . 1 Amps/T yp e 75 ° C Wire Size - A WG 208V 230V 208V 230V 208V 230V AHE18B3XH21 6HK*6500206 10.0 14.33 15.48 15 20 12 12 ...

  • York AHE18 THRU 60' - page 8

    8 Johnson Controls Unitary Products 680210-YTG-B-03 11 ELECTRICAL DA T A - (FOR MUL TI-SOURCE POWER SUPPL Y) - COPPER WIRE - 208/230-1-60 1 Models Heater Models Min. Circuit Ampacity Max. O.C.P . 2 Amp s/T yp e 75 ° C Wire Size - A WG Circuit Circuit Circuit 1st 2nd 1st 2nd 1st 2nd 208/230 208/230 208/230 208/230 208 /230 208/230 AHE24B3XH21 6HK16 ...

  • York AHE18 THRU 60' - page 9

    Johnson Controls Unitary Pro ducts 9 680210-YTG-B-0311 2. Heaters are 3 Phase. TYPICAL APPLICA TIONS ACC ES SO RI ES Refer to Price Manual for spec ific model numbers where not shown. TXV Kits - TXV kits are available for “Flex-coil” applications and converting R-22 to R-410A or as a service replacement. Al l kits are bolt-on and re quire no br ...

  • York AHE18 THRU 60' - page 10

    10 Johnson Controls Unitary Products 680210-YTG-B-03 11 TYPICAL THERMOST A T CONNECTION ...

  • York AHE18 THRU 60' - page 11

    Johnson Controls Unitary Pro ducts 11 680210-YTG-B-0311 TYPICAL THER MOSTAT W IRING FOR 2-STAGE HEAT PUMP WITH ECM BLOWER MOTOR ...

  • York AHE18 THRU 60' - page 12

    12 Johnson Controls Unitary Products 680210-YTG-B-03 11 AIR FLOW AIR FLOW DA T A - 60 Hz MODELS - 208 VOL T Models Blower Motor Speed CFM 1 @ External St atic Pressure - IWC 1. Dry coil conditions only , tested without filters. Air handler unit s are CSA listed to UL 1995/CSA C22.2 236 -05 up t o 0.30" w .c. external static pressure, including ...

  • York AHE18 THRU 60' - page 13

    Johnson Controls Unitary Pro ducts 13 680210-YTG-B-0311 AIR FLOW DA T A - 60 Hz MODELS - 230 VOL T Models Blower Motor Speed CFM 1 @ External Static Pressure - IWC 0.10 0.20 0.30 0.40 0.50 0.60 0.70 230 V o lt AHE18B3XH21 High #5 1075 1041 1003 970 930 88 5 842 Med High #4 895 845 808 767 709 647 561 Med #3 663 618 557 490 348 267 192 Med Low #2 62 ...

  • York AHE18 THRU 60' - page 14

    Subject to change without notice. Published in U .S.A. 680210-YTG-B-0311 Copyright © 201 1 by Johnson Controls, Inc. All ri ghts reserved. Supersedes: 680210-YTG-A-021 1 Johnson Controls Unitary Product s 5005 Y ork Drive Norman, OK 73069 ...

メーカー York カテゴリー Air Conditioner

York AHE18 THRU 60'のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AHE18 THRU 60'の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork AHE18 THRU 60'の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York AHE18 THRU 60'の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York AHE18 THRU 60'の取り付け説明書、サービスマニュアル、簡易説明書、またはYork AHE18 THRU 60'のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York AHE18 THRU 60'の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York AHE18 THRU 60'デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork AHE18 THRU 60'を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork AHE18 THRU 60'ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York AHE18 THRU 60'の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork AHE18 THRU 60'の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York AHE18 THRU 60'に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York AHE18 THRU 60'デバイスの基本機能を使うにあたってのヒント。 York AHE18 THRU 60'のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York AHE18 THRU 60'に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork AHE18 THRU 60'のメーカー/サービスへの連絡先に関する情報。

York AHE18 THRU 60'についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork AHE18 THRU 60'の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork AHE18 THRU 60'で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください