    Instructions–Parts List 307674R EN Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. 3:1 Ratio President R Pump Used for transfer , supply , and recirculation of compatible fluids. For professional use only . 360 psi (2.5 MPa, 25 bar) Maximum Fluid Working Pressure 120 psi (0.8 MPa, 8.3 bar) ...

  • Graco 218747 - page 2

    2 307674 T able of Contents W arnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Graco 218747 - page 3

    307674 3 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury . D This equipment is for professional use only . D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not su ...

  • Graco 218747 - page 4

    4 307674 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while using ...

  • Graco 218747 - page 5

    307674 5 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor . If you supply your own accessories, be sure they are ade- quately sized and pressure rate ...

  • Graco 218747 - page 6

    6 307674 Installation Fig. 2 06089 KEY A Bleed-T ype Master Air V alve (required, for pump) B Air Filter/Regulator C Air Line Lubricator D Fluid Drain V alve (required) E Surge T ank F Fluid Shutoff V a lves G Fluid Filter H Fluid Pressure Regulator J Air Spray Gun K Back Pressure Regulator L Pump M Air Supply Line N Bleed-T ype M aster Air V a lve ...

  • Graco 218747 - page 7

    307674 7 Installation A vailable Accessories (must be purchased separately) Air Line Accessories W ARNING A bleed-type master air valve (A) is required in your system to help reduce the risk of serious injury , including splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjust- ing or repairing the pump. The ble ...

  • Graco 218747 - page 8

    8 307674 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally . T o reduce the risk of an injury from acci- dental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Proce- dure whenever you ...

  • Graco 218747 - page 9

    307674 9 Operation Prime the Pump 1. See Fig. 2. Remove the spray nozzle from the gun. See the gun instruction manual. 2. Close all bleed-type air valves (A, N). 3. Close the pump air filter/regulator (B). 4. Close the fluid drain valve (D). 5. Check that all fittings throughout the system are tightened securely . 6. Connect the air supply line to ...

  • Graco 218747 - page 10

    10 307674 Maintenance Shutdown and Care of the Pump W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. For overnight shutdown, stop the pump at the bottom of its stroke to prevent fluid from drying on the ex- posed displacement rod and damaging the t ...

  • Graco 218747 - page 11

    307674 1 1 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Relieve the pressure. 2. Check all possible problems and solutions before disassembling pump. Problem Cause Solution Pump fails to operate. Restricted line or inadequat ...

  • Graco 218747 - page 12

    12 307674 Service Disconnecting the Displacement Pump NOTE: For displacement pump repair instructions, refer to the separate displacement pump manual 307652, supplied. W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Flush the pump if possible. ...

  • Graco 218747 - page 13

    307674 13 Service 06108 Fig. 4 1 2 T orque to 65–75 ft-lb (88–102 N.m). Lubricate. 1 3 Apply thread sealant. 3 2 2 4 12 6 13 8 2 3 1 20 21 14 12 13 11 10 R 15 S Model 218747 Shown ...

  • Graco 218747 - page 14

    14 307674 Parts Model 218747, Series C 3:1 Ratio President Pump, Stubby Size; UHMWPE and Leather Packed Model 237142, Series A 3:1 Ratio President Pump, Stubby Size; Leather Packed with PTFE Backup Model 237143, Series A 3:1 Ratio President Pump, Stubby Size; Leather and PTFE Packed Model 237146, Series A 3:1 Ratio President Pump, Stubby Size; PTFE ...

  • Graco 218747 - page 15

    TI0498 1 2 3 4 6 8 10 11 12 15 or 7 20 21 12 13 13 1 Use d on Models 237144 and 237145 only . 2 Used on Model 218795 only (not shown). 1 2 11 3 Used on Models 218795 and 237144 only . 4 Used on Model 237145 only . 3 4 307674 15 Parts Model 218795, Series C 3:1 Ratio President Pump, 55 Gallon (200 Liter) Drum Size; UHMWPE and Leather Packed Model 23 ...

  • Graco 218747 - page 16

    16 307674 Dimensions 061 10 A B C Model No. A B C 218795 48.88 in. (1242 mm) 16.38 in. (416 mm) 32.5 in. (826 mm) 237144, 237145 48.95 in. (1244 mm) 16.45 in. (418 mm) 32.5 in. (826 mm) 218747 36.38 in. (924 mm) 16.38 in. (416 mm) 20 in. (508 mm) 237142, 237143, 237146 36.45 in. (926 mm) 16.45 in. (418 mm) 20 in. (508 mm) Mounting Hole Layout 2.254 ...

  • Graco 218747 - page 17

    307674 17 T echnical Data Category Data Ratio 3:1 Maximum fluid working pressure 360 psi (2.5 MPa, 25 bar) Maximum air input pressure 120 psi (0.8 MPa, 8.3 bar) Pump cycles per 1 gallon (3.8 liters) 6 Fluid flow at 60 cycles per minute 10 gpm (38 liters/min) Fluid inlet size 1–1/2 npt(f) Fluid outlet size 1 in. npt(f) Air inlet size 3/8 npsm(f) W ...

  • Graco 218747 - page 18

    18 307674 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a period of twelve months from th ...

メーカー Graco カテゴリー Heat Pump

Graco 218747のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 218747の取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco 218747の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco 218747の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco 218747の取り付け説明書、サービスマニュアル、簡易説明書、またはGraco 218747のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco 218747の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco 218747デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco 218747を使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco 218747ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco 218747の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco 218747の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco 218747に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco 218747デバイスの基本機能を使うにあたってのヒント。 Graco 218747のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco 218747に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco 218747のメーカー/サービスへの連絡先に関する情報。

Graco 218747についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco 218747の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco 218747で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)