Echo X750-006の取扱説明書

24ページ 0.55 mb
ダウンロード

ページに移動 of 24

Summary
  • Echo X750-006 - page 1

    Power Blower Operator ’ s Manual MODEL PB-410 X750-006 20 1 X750109-290 1 W ARNING D ANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator’s Manual which must be read and understood for proper and safe operation. Printed in Japan 0501Gjb 0044 ES ...

  • Echo X750-006 - page 2

    2 T ABLE OF C ONTENTS THE OPERA T OR ’ S MANU AL -- contains specifications and information for operation, starting, stopping, maintenance, storage and assembly specific to this product. Introductio n .............................................................. 2 - The Operator’s Manual .................................. 2 Manual Safety Symbo ...

  • Echo X750-006 - page 3

    3 P O WER B LO WER O PERA T OR ’ S M ANU AL IMPORTANT N O T E M ANU AL S AFETY S YMBOLS AND I MPORT ANT I NFORMA TION Throughout this manual and on the product itself, you will find safety alerts and helpful, information messages preceded by symbols or key words. The following is an explanation of those symbols and key words and what they mean to ...

  • Echo X750-006 - page 4

    4 Symbol description/application Symbol form/shape Symbol description/application Symbol form/shape Read and under- stand Operator’s Manual. Fuel and oil mixture Symbol description/application Symbol form/shape Symbol description/application Symbol form/shape Hot Surface Carburetor adjustment - Idle speed Carburetor adjustment - High speed mixtur ...

  • Echo X750-006 - page 5

    5 P O WER B LO WER O PERA T OR ’ S M ANU AL PERSONAL CONDITION AND SAFETY EQUIPMENT W ARNING D ANGER Power Blower users risk injury to themselves and others if the Power Blower is used improperly and/or safety precautions are not followed. Proper clothing and safety gear must be worn when operating a Power Blower. Physical Condition -- Your judgm ...

  • Echo X750-006 - page 6

    6 15 m (50 ft.) SAFE OPERA TION Determine Operation Area -- • Do not operate this product indoors or in inadequately ventilated areas. • Review area to be cleared. Look for potential hazards such as stones or metal objects. • Spectators and fellow workers must be warned, and children and animals prevented from coming nearer than 15 m (50 ft.) ...

  • Echo X750-006 - page 7

    7 P O WER B LO WER O PERA T OR ’ S M ANU AL EXTENDED OPERA TION / EXTREME CONDITIONS V ibration and Cold -- It is believed that a condition called Raynaud’s Phenomenon, which affects the fingers of certain individuals may be brought about by exposure to vibration and cold. Exposure to vibration and cold may cause tingling and burning sensations ...

  • Echo X750-006 - page 8

    8 D ESCRIPTION EMISSION CONTROL EP A Phase II The emission control system for these engines are EM (Engine Modification). An Emission Control Label is located on the engine. (This is an EXAMPLE ONLY, information on label varies by engine FAMILY). PRODUCT EMISSION DURABILITY The 300 hours emission durability period is the time span selected by the m ...

  • Echo X750-006 - page 9

    9 P O WER B LO WER O PERA T OR ’ S M ANU AL 1 2 3 4 5 6 7 8 9 1. AIR CLEANER - Contains replaceable air filter element. 2. SPARK PLUG - Provides spark to ignite fuel mixture. 3. MUFFLER/SPARK ARRESTOR - The spark arrestor muffler controls the exhaust noise while the spark arrestor prevents hot, glowing particles of carbon from leaving the muffler ...

  • Echo X750-006 - page 10

    10 S PECIFICA TIONS PB-410 330 mm (13.0 in.) (w/o pipes) 440 mm (17.3 in.) 440 mm (17.3 in.) 9.7 kg (21.4 Ib.) (w/o pipes) Air cooled, two-stroke, single cylinder gasoline engine 39.7 mL (2.42 cu. in.) 38.0 mm (1.50 in.) 35.0 mm (1.38 in.) Walbro Diaphragm, model WT-684 Flywheel Magneto, capacitor discharge ignition type NGK BPM-8Y Gap 0.65 mm (0.0 ...

  • Echo X750-006 - page 11

    11 P O WER B LO WER O PERA T OR ’ S M ANU AL A SSEMBL Y W ARNING D ANGER Never perform maintenance or assembly procedures with engine running or serious personal injury may result. INST ALL BLO WER PIPES 1. Assemble throttle lever bracket to the fancase using four screws. - Set stop lead into the recess of bracket. 2. Assemble the flexible pipe t ...

  • Echo X750-006 - page 12

    12 P RE -O PERA TION FUEL Fuel Requirements Gasoline - Use 89 Octane [R+M/2] (mid grade or higher) gasoline known to be good quality. Gasoline may contain up to 15% MTBE (methyl tertiary-butyl ether). Gasohol containing methyl (wood) alcohol is NOT approved. Two Stroke Oil - A two-stroke engine oil meeting ISO-L-EGD (ISO/CD 13738) and J.A.S.O. FC S ...

  • Echo X750-006 - page 13

    13 P O WER B LO WER O PERA T OR ’ S M ANU AL SM T W T F S 1234 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Mixing Instructions 1 . Fill an approved fuel container with half of the required amount of gasoline. 2 . Add the proper amount of 2-stroke oil to gasoline. 3 . Close container and shake to mix oil with gasoli ...

  • Echo X750-006 - page 14

    14 O PERA TION - Provide all operators of this equipment with the Operator’s Manual and instructions for safe operation. - Check unit for loose nuts, bolts and screws daily. - Recoil starter: Use short pulls - only 1/2 - 2/3 of rope length for starting. Do not allow the rope to snap back in. Always hold the unit firmly. - Rotate spring loaded thr ...

  • Echo X750-006 - page 15

    15 P O WER B LO WER O PERA T OR ’ S M ANU AL OPERA TING BLO WER W ARNING D ANGER Always wear safety glasses, hearing protection, a face filter mask and take all safety precautions or serious personal injury may result. Do not point the blower pipe in the direction of people or pets. Read the Safety Section carefully. IMPORTANT To avoid engine dam ...

  • Echo X750-006 - page 16

    16 M AINTENANCE Your ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your unit to an ECHO Service Dealer for maintenance. To help you decide whether you want to DO-IT-YOUR ...

  • Echo X750-006 - page 17

    17 P O WER B LO WER O PERA T OR ’ S M ANU AL AIR FIL TER Level 1. NOTE Clean daily. 1. Close choke (Cold Start Position). This prevents dirt from entering the carburetor throat when the air filter is removed. Brush accumulated dirt from the air cleaner area. 2. To take out a air filter, loosen both clamps of air cleaner and remove filter cover as ...

  • Echo X750-006 - page 18

    18 INTAKE GRILL 0.65 mm (0.026 in.) W ARNING D ANGER Muffler and catalytic mufflers operate at extremely high tempera- tures. Muffler area must be kept clean. Do not perform maintenance on the engine or muffler until engine and muffler are completely cool, otherwise serious personal injury may occur. SP ARK PLUG Level 2. 1. Remove spark plug and ch ...

  • Echo X750-006 - page 19

    19 P O WER B LO WER O PERA T OR ’ S M ANU AL Cleaning Cylinder Fins • Check periodically. - Clogged fins result in poor engine cooling. - Clean the passage of air between the cylinder fins to let cooling air pass easily. Cylinder fins Spark arrestor cover Gaskets Spark arrestor screen EXHA UST SYSTEM Spark Arrestor Screen Level 2. IMPORTANT Car ...

  • Echo X750-006 - page 20

    20 CARBURET OR ADJUSTMENT Engine Break-In New engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can be made. During the break- in period your engine performance will increase and exhaust emissions will stabilize. Idle speed can be adjusted as required. High Altitude Adjustment High altitude adju ...

  • Echo X750-006 - page 21

    21 P O WER B LO WER O PERA T OR ’ S M ANU AL T R OUBLESHOOTING W ARNING DANGER Fuel vapors are extremely flammable and may cause fire and/or explosion. Never test for ignition spark by ground- ing spark plug near cylinder plug hole, otherwise serious personal injury may result. Probl e m Che ck Sta tus Caus e Rem e dy Fue l at c arburet or No fue ...

  • Echo X750-006 - page 22

    22 W ARNING D ANGER During operation the muffler or catalytic muffler and surrounding cover becomes hot. Always keep exhaust area clear of flammable debris during transportation or when storing, otherwise serious property damage or personal injury may result. W ARNING D ANGER Do not store where fuel fumes may accumulate or reach an open flame or sp ...

  • Echo X750-006 - page 23

    23 P O WER B LO WER O PERA T OR ’ S M ANU AL NOTES ...

  • Echo X750-006 - page 24

    ECHO, INCORPORA TED 400 Oakwood Road Lake Zurich, IL 60047-1564 www .echo-usa.com S E RVICING I NFORMA TION P ARTS Genuine ECHO Parts and ECHO REPOWER™ Parts and Assemblies for your ECHO products are available only from an Authorized ECHO Dealer. When you do need to buy parts always have the Model Number and Serial Number of the unit with you. Yo ...

メーカー Echo カテゴリー Blower

Echo X750-006のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- X750-006の取扱説明書
- Echoの製品カード
- パンフレット
- またはEcho X750-006の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Echo X750-006の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Echo X750-006の取り付け説明書、サービスマニュアル、簡易説明書、またはEcho X750-006のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Echo X750-006の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Echo X750-006デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEcho X750-006を使用するのを助ける技術的文書のことです。説明書は通常、全てのEcho X750-006ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Echoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Echo X750-006の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEcho X750-006の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Echo X750-006に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Echo X750-006デバイスの基本機能を使うにあたってのヒント。 Echo X750-006のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Echo X750-006に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEcho X750-006のメーカー/サービスへの連絡先に関する情報。

Echo X750-006についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEcho X750-006の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEcho X750-006で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)