Oneida Air Systems 2000の取扱説明書

21ページ 1.79 mb
ダウンロード

ページに移動 of 21

Summary
  • Oneida Air Systems 2000 - page 1

    Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .oneida-air .com Shown with optional bolt together Angle Iron stand and optional 55 gal. steel drum. *Models may vary sligthly in appearance. - Baldor Dust Collector ...

  • Oneida Air Systems 2000 - page 2

    1 Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes ...

  • Oneida Air Systems 2000 - page 3

    2 I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely before operating collector: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3. Have licensed electrician wire Fan / Blower acc ...

  • Oneida Air Systems 2000 - page 4

    3 II. Pro Series 2000 Configurations Caution: If exhaust air is vented outside you must provide make up / return air . Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances. 1. External Cartridge Filter - Silencer Included with Filter Pro 2000 Owners Manual Silencer included w/ Filter O.A.S. 200 ...

  • Oneida Air Systems 2000 - page 5

    III. General Specifications & Fan Per formance Cur ves Pro 2000 Owner  s Manual O.A.S. 2007 c 4 S tatic pressure and volume together determine a fans performance. Several factors, such as layout of ductwork and diameter of openings, can affect a fan s performance. 1973 CFM @ 2 SP w/c w/o filter Full 16 gauge galvanized cyclone & ...

  • Oneida Air Systems 2000 - page 6

    5 IV . Dimensions For Minimum Mounting Heights w/ 62 Filter . *Dimensions subject to slight variation in manufacturing. Pro 2000 Owner  s Manual O.A.S. 2007 c 00.00 72.00 81. 00 35 Gal Shown Add 8 " fo r 55 Gal 62.00 4.00 8.00 18.00 18.00 27.00 53.00 60.00 1 Dime nsions s hown wit h 5" f lex hose between drum and cone collars 8.00 1 ...

  • Oneida Air Systems 2000 - page 7

    V . General Assembly Pro 2000 Owner  s Manual O.A.S. 2007 c 6 Cyclone Barrel Cone Square to Round Connects to Inlet 1. Motor/Blower Assembly BXI012309-1ph - - 3ph 1a. Fan Wheel - BWX159800 Magnetic Starter w/ Remote Option: 1 phase 1b. Motor Starter - AMR221417 1phase only 1c. Cord Connector - WWC027063 1 phase only 1d. Cord Connector Locknut - ...

  • Oneida Air Systems 2000 - page 8

    Note: For cyclonic presep aration there must be an air tight seal between cyclone and dust cont ainer . Dust bin must be located vertically under cyclone, material drop s down by gravity . 7 Pro 2000 Owner  s Manual O.A.S. 2007 c VI. General Assembly Instructions Cyclone Barrel Cyclone Cone 2. Cyclone Barrel Air Inlet Fan / Blower Housing 1. Air ...

  • Oneida Air Systems 2000 - page 9

    8 Pro 2000 Owner  s Manual O.A.S. 2007 c VII. Bracket Assembly 1. Y ou must determine the direction the fan outlet will point to proceed with this mounting assembly . The collector will seem quieter if the outlet is aimed away from the area people tend to work. Slots in the bracket s are .406 x 1.00 Note: Bolts included to mount bracket to ...

  • Oneida Air Systems 2000 - page 10

    VIII. Filter Assembly 9 Pro 2000 Owner  s Manual O.A.S. 2007 c Note: Do not return exhaust air to the shop unless filter media is added. External 62 Filter Assembly 1. Attach cartridge with hardware provided making sure gasket is attached. See Fig. 1 2. If Filter requires additional support. Use the plate at the top of the filter to support t ...

  • Oneida Air Systems 2000 - page 11

    10 IX . Filter Maintenance External Filter Cartridge Cleaning Intervals Caution: Fine dust collected in filter is hazardous to your health! Do not breathe! When unit is turned of f, use compressed air to blow dust off from exterior of filter . Hold nozzle at least 8 away from filter pleats*. Do not remove bottom dust pan before or during the blo ...

  • Oneida Air Systems 2000 - page 12

    X . Filter Efficiency Gauge Mounting Instructions Mounting Instructions 1. Mount brass static pressure tube in plenum with tip pointed into the air stream. Use mounting bracket and sheet metal screws if interior of plenum is not accessible. Refer to drawings for location of brass static pressure tube. Gauge R eading Instructions 1. Gauge may need t ...

  • Oneida Air Systems 2000 - page 13

    12 XI. Directions for Cleaning External Filter Pro 2000 Owner  s Manual O.A.S. 2007 c The External Filter can be cleaned using the following methods: W ait a few minutes for internal dust to settle then unclip and carefully empty dust bin. Keep nozzle at least 6 from filter and keep your pressure down. Closer blasts may damage filter material ...

  • Oneida Air Systems 2000 - page 14

    13 Pro 2000 Owner  s Manual O.A.S. 2007 c XII. Wiring Instructions for Magnetic Star ter Always use a licensed, professional electrician. Follow Wiring Diagram on Motor . Note: This Dust Collector is pre-wired at the factory and need only be plugged into a NEMA 6020R dedicated electrical receptacle. 5hp single phase only . ...

  • Oneida Air Systems 2000 - page 15

    Unplug unit before servicing or cleaning. 13 XIII. Troubleshooting 14 Pro 2000 Owner  s Manual O.A.S. 2007 c ...

  • Oneida Air Systems 2000 - page 16

    XIV . Fire Hazards - Read Before Installing and Operating Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector . Never introduce sparks or sources of ignition into the dust collector . Personnel should keep at least 20 feet away ...

  • Oneida Air Systems 2000 - page 17

    XV . T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive concealed ...

  • Oneida Air Systems 2000 - page 18

    17 Pro 2000 Owner  s Manual O.A.S. 2007 c XVI. Stand Assembly - STG023055 Bolt W asher S tand Nut 68 23 7/8 23 7/8 23 7/8 23 7/8 23 7/8 23 7/8 23 7/8 (32) 5/16 Bolts (32) 5/16 Nuts (64) 5/16 Flat W ashers FRONT has no lower brace across. LEFT RIGHT ...

  • Oneida Air Systems 2000 - page 19

    Pro 2000 Owner  s Manual O.A.S. 2007 c XVII. Accessories Bolt T ogether Angle Iron S tand STG023055 - 55 gal. S tand Replacement Filter FCS186200 Dust Containers 35 gal. Fiber 55 gal. Fiber 55 gal. S teel ABX000000 The BAG Gripper provides the ability to use convenient plastic bags inside your dust drum. It provides a constant, negative pressure ...

  • Oneida Air Systems 2000 - page 20

    19 Pro 2000 Owner  s Manual O.A.S. 2007 c XVIII. Fan Motor Maintenance Per Baldor specifications, their 2 pole motors (3600 RPM) motors are to be relubricated every 5500 hours. T able 1 - Service Conditions T able 2 - Lubrication Interval Multiplier Per Baldor specifications, add .30 ounces (8.4 grams) of Mobil Polyrex grease by weight or .6 cub ...

  • Oneida Air Systems 2000 - page 21

    Retrofit (Wiring) of Wireless Remote into 220V Control Circuit of Square D / T elemecanique Mag Starters Remote Black Box 6T3 4T2 2T1 A2 A1 13NO 5L3 3L2 1L1 Contactor Overload 98 97 95 96 Amp Adjustment Dial YEL BRN BRN YEL RED RED RED RED Wire Nuts Start Stop Start / Stop Push Button Assembly on Starter (Molex) 3 Wire Adaptor Molex AMA000000 ...

メーカー Oneida Air Systems カテゴリー Dust Collector

Oneida Air Systems 2000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 2000の取扱説明書
- Oneida Air Systemsの製品カード
- パンフレット
- またはOneida Air Systems 2000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Oneida Air Systems 2000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Oneida Air Systems 2000の取り付け説明書、サービスマニュアル、簡易説明書、またはOneida Air Systems 2000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Oneida Air Systems 2000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Oneida Air Systems 2000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOneida Air Systems 2000を使用するのを助ける技術的文書のことです。説明書は通常、全てのOneida Air Systems 2000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Oneida Air Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Oneida Air Systems 2000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOneida Air Systems 2000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Oneida Air Systems 2000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Oneida Air Systems 2000デバイスの基本機能を使うにあたってのヒント。 Oneida Air Systems 2000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Oneida Air Systems 2000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOneida Air Systems 2000のメーカー/サービスへの連絡先に関する情報。

Oneida Air Systems 2000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOneida Air Systems 2000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOneida Air Systems 2000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)