    INSTALLATION & OPERATIONAL MANUAL 1GRBD & GRBDF SERIES GAS FRYERS With KleenScreen PLUS ® Filtration Systems M O D E L S : 1G4BD ML-136647 1G6BD ML-136648 1G8BD ML-136649 2G4BDF ML-136650 3G4BDF ML-136653 4G4BDF ML-136656 2G6BDF ML-136651 3G6BDF ML-136654 4G6BDF ML-136657 2G8BDF ML-136652 3G8BDF ML-136655 4G8BDF ML-136681 2XG4BDF ML-136658 ...

  • Vulcan-Hart ML-136648 - page 2

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE E ...

  • Vulcan-Hart ML-136648 - page 3

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY……………………………… ………. 2 INTRODUCTION…………………… …………………………………… … 4 GENERAL…………………………… ……………………………… 4 ORDERING PARTS…? ...

  • Vulcan-Hart ML-136648 - page 4

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance. Before installing the fryer, thoroughly read th is manual and carefully fo llow all instruction ...

  • Vulcan-Hart ML-136648 - page 5

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -5- Check that the followi ng have been included:  Crumb Rack(s)  Basket Hanger(s)  Tank Brush  Adjustable Casters (4) two locking, two non- locking for freestanding fryers. Fryer Batteries with the KleenScreen PLUS ® Filtration System have casters installed from the f ...

  • Vulcan-Hart ML-136648 - page 6

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -6- Clearances:  Minimum clearance from combustible construction: 6” (15 cm) from the sides of the fryer 6” (15 cm) from t he back of the fryer The fryer may be installed on combustible floors.  Minimum clearance from noncombustible construction: 0” from the sides of th ...

  • Vulcan-Hart ML-136648 - page 7

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -7-  National Electrical Code, ANSI/NFPA-70 (l atest edition). Copies may be obtained from The National Fire Protection Asso ciation, Batteryma rch Park, Quincy, MA. 02169-7471.  In the commonwealth of Massachusetts all gas appliances vented through a ventilation hood or exha ...

  • Vulcan-Hart ML-136648 - page 8

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -8- GAS CONNECTION All gas supply connections and any pipe joint compound must be resist ant to the action of propane gases. The gas inlet is located on the lower rear of the fryer. Codes requ ire that a gas shutoff valve be installed in the gas line ahead of the fryer. The gas sup ...

  • Vulcan-Hart ML-136648 - page 9

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -9-  When installing a quick disconnect you must also install a means for limiting the movement of the fryer. This device will prevent the gas line or quick disconnect from being strained. The restraining devic e should be attached to the cutout on the back panel. See illustrati ...

  • Vulcan-Hart ML-136648 - page 10

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -10- LEVELING THE FRYER Check the level of the fryer by placing a le vel on top of the fryer after gas connections have been made. Ensure that the fryer is level front-to-back and side-to-side in the final installed position. If using casters, lock the wheels after unit is level. O ...

  • Vulcan-Hart ML-136648 - page 11

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -11- FILLING TANK WITH SHORTENING  Close the drain valve.  Fill the fryer tank with s hortening. Vulcan recommends using liquid shortening.  Shortening level should be between the MIN and MAX lines in the fryer tank.  Shortening will expand when heated. Do not fill the ...

  • Vulcan-Hart ML-136648 - page 12

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -12- Fry Basket Guidelines  Do not overfill baskets. (See fry basket c apacity below) Carefully lower basket into oil.  When frying doughnuts and fritters, turn product only once during frying.  When cooking French fries or onion rings, shake the basket several times.  ...

  • Vulcan-Hart ML-136648 - page 13

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -13- Solid State Knob Control Temperature Knob Control Melt Switch Power Switch Filter Switch (for those models with Klee nScreen PLUS ® F i l t e r S y s t e m s ) Start Button TURNING ON THE FRYER  Open the door to the fryer. Select Liquid or Solid Shortening pressing the swi ...

  • Vulcan-Hart ML-136648 - page 14

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -14- EXTENDED SHUTDOWN 1. Open the door to the fryer. Press the power switch to the OFF position. 2. Thoroughly drain the fryer. Refer to DRAINING THE FRYER. 3. Clean the fryer according to CLEANING. 4. Turn off the main gas shutoff valve. FILTERING THE OIL Hot oil and hot parts ca ...

  • Vulcan-Hart ML-136648 - page 15

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -15- DRAINING THE TANK 1. Open the door to the fryer. T he power must remain ON for t he fryer to filter correctly. 2. Insert the drain extension into t he drain valve. Tighten only hand tight. 3. Direct the drain spout into the container t hat you want to drain the shortening into ...

  • Vulcan-Hart ML-136648 - page 16

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -16- 9. Drain the tank according to DRAINING THE TANK. Rinse thoroughly with clear, hot water. All traces of cleaner must be removed. Dry the tank thoroughly. 10. Close the drain valve and add shorteni ng. Follow the FILLING TANK WITH SHORTENING procedure in this manual. The fryer ...

  • Vulcan-Hart ML-136648 - page 17

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -17- KleenScreen Plus ® Filtration System Installation and Operational Manual for “BDF” Models 2 G 4 B D F S h o w n GAS KleenScreen PLUS® Models: 2G4BDF ML-136650 3G4BDF ML-136653 4G4BDF ML-136656 2G6BDF ML-136651 3G6BDF ML-136654 4G6BDF ML-136657 2G8BDF ML-136652 3G8BDF ML- ...

  • Vulcan-Hart ML-136648 - page 18

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -18- Filtering Instructions for KleenScreen PLUS ® Fryers General The KleenScreen PLUS ® filtration system filters t he oil as it is pumped back into its’ respective tank(s). Only one tank can be dr ained and filtered at a time. Unde r no circumstances should both tanks be drai ...

  • Vulcan-Hart ML-136648 - page 19

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -19- Fully assembled filter screen assembly: F i g . 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig. 3 Micro-Filtration Fabric Envelope Assembly: Same Suction Tube F a b r i c E n v e l o p e I n s e r t (Different from Screen Assembly) Fab ...

  • Vulcan-Hart ML-136648 - page 20

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -20- INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS ® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RA TE WE RECOMME ND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE). Step 1 Discard all oil from the filter vessel, (see ...

  • Vulcan-Hart ML-136648 - page 21

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -21- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank. Never run water or boil out solution thr ough filt ...

  • Vulcan-Hart ML-136648 - page 22

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -22- Quick Start Guide for Solid State Knob Controls: Start up in 4 Easy Steps: Step 1: Fill fry tank with oil and t hen turn on the power. Step 2: Set temperature knob to the desired set temperature. S t e p 3 : Move the MELT switch to the correct shortening being used: Solid or L ...

  • Vulcan-Hart ML-136648 - page 23

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -23- Quick Start Guide for Solid State Kn ob Controls with KleenScreen PLUS ® Filtration: Filtering in 6 Easy Steps: Step 1: Make sure that the powe r is on. Do NOT turn off the power to the fryer. Step 2: Open the drain valve slow ly allowing the oil to drain down into the filter ...

  • Vulcan-Hart ML-136648 - page 24

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -24- FILTERING TIP: Open the filtering drawer approximately 1” to allow any oil in the re turn line to run back into the filter pan. This will take about 30 seconds to complete. Then open the drawer completely to clean filter components. REMOVING EXCESS DEBRIS FROM THE SCREEN FIL ...

  • Vulcan-Hart ML-136648 - page 25

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -25- BOIL OUT PROCEDURE: Use the Boil Out By-Pass™ drai n extension allowing the boil out solution to exit the fry tank without using the filtering system. Do not allow water to run through the motor / pump. Drain the boil out solution into a bucket or place a hose on the end of ...

  • Vulcan-Hart ML-136648 - page 26

    GBD_GBDF SERIES GAS FRYERS VULCAN-HART F-329 34 Rev. B (June 2008 ) -26- MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, clean ing, and servicing the fryer. Spilling hot fryer com pound can cause severe burns. Do not move fryer without draining all frying compound from the tank. FLUE VENT INSPECTION When the fryer is coo ...

メーカー Vulcan-Hart カテゴリー Fryer

Vulcan-Hart ML-136648のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ML-136648の取扱説明書
- Vulcan-Hartの製品カード
- パンフレット
- またはVulcan-Hart ML-136648の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vulcan-Hart ML-136648の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vulcan-Hart ML-136648の取り付け説明書、サービスマニュアル、簡易説明書、またはVulcan-Hart ML-136648のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vulcan-Hart ML-136648の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Vulcan-Hart ML-136648デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVulcan-Hart ML-136648を使用するのを助ける技術的文書のことです。説明書は通常、全てのVulcan-Hart ML-136648ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vulcan-Hartの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vulcan-Hart ML-136648の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVulcan-Hart ML-136648の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vulcan-Hart ML-136648に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vulcan-Hart ML-136648デバイスの基本機能を使うにあたってのヒント。 Vulcan-Hart ML-136648のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vulcan-Hart ML-136648に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVulcan-Hart ML-136648のメーカー/サービスへの連絡先に関する情報。

Vulcan-Hart ML-136648についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVulcan-Hart ML-136648の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVulcan-Hart ML-136648で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)