    Manual 2100-533A Page 1 of 1 2 OPERA TION INSTRUCTIONS Model: 920-0074 QWSER V ENERGY RECOVER Y VENTILA T O R WITH EXHAUST For Use With Bard 2 Through 5 T on QW*S Series Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual: 2100-533A Supersedes: 2100- 533 File: Volume II, Tab 14 Date: 12-08-10 ...

  • Bard 920-0074 qwserv - page 2

    Manual 2100-533A Page 2 of 1 2 CONTENTS Electrical S pecifications .............................. ............ 3 General Description of ERV ................................... 3 Control Requirements ............................................ 3 Recommended Control Sequences ....................... 4 Control Wiring ................................. ...

  • Bard 920-0074 qwserv - page 3

    Manual 2100-533A Page 3 of 1 2 GENERAL DESCRIPTION The Energy Recovery Ventilator was designed to provide energy efficient, cost effective ventilation to meet I. A. Q. (Indoor Air Quality) requirements while still maintaining good indoor comfort and humidity control for a variety of applications such as schools, classrooms, lounges, conference room ...

  • Bard 920-0074 qwserv - page 4

    Manual 2100-533A Page 4 of 1 2 The ERV units are wired from the factory on medium intake and low exhaust speeds. The ERV is equipped with independently controlled 3-speed motor to provide the capability of adjusting the ventilation rates to the requirements of the specific application and to be able to provide positive pressure in the structure. Th ...

  • Bard 920-0074 qwserv - page 5

    Manual 2100-533A Page 5 of 1 2 PERFORMANCE AND APPLICATION DATA TABLE 2 SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS 75° DB / 62° WB) LEGEND VLT = Ventilation Load – Total HRT = Heat Recovery – Total VLS = Ventilation Load – Sensible HRS = Heat Recovery – Sensible VLL = Ventilation Load – Latent HRL = Heat Recovery – Latent t ...

  • Bard 920-0074 qwserv - page 6

    Manual 2100-533A Page 6 of 1 2 ENERGY RECOVERY VENTILATOR MAINTENANCE GENERAL INFORMATION The ability to clean exposed surfaces within air moving systems is an important design consideration for the maintenance of system performance and air quality. The need for periodic cleaning will be a function of operating schedule, climate, and contaminants i ...

  • Bard 920-0074 qwserv - page 7

    Manual 2100-533A Page 7 of 1 2 CLEANABILITY AND PERFORMANCE In order to maintain energy recovery ventilation systems, energy transfer surfaces must be accessible for washing to remove oils, grease, tars and dirt that can impede performance or generate odors. Washing of the desiccant surfaces is required to remove contaminate buildups that can reduc ...

  • Bard 920-0074 qwserv - page 8

    Manual 2100-533A Page 8 of 1 2 FIGURE 2 BELT REPLACEMENT INSTRUCTIONS Belt Replacement Instructions MIS-2166 Route (1) replacement belt in bottom groove of pulley. Route (1) replacement belt in top groove of pulley. If belts "squeak" or "chirp" lubricate lightly with LPS-1 or equivalent "dry film" lubricant. ...

  • Bard 920-0074 qwserv - page 9

    Manual 2100-533A Page 9 of 1 2 FIGURE 3 HUB ASSEMBLY WITH BALL BEARINGS ...

  • Bard 920-0074 qwserv - page 10

    Manual 2100-533A Page 10 of 1 2 2 1 3456789 1 0 1 1 1 2 2 1 3 208 120 V 480 240 COM 24 2 4 3 1 Contro l Relay Damper Motor 27 3 Motor 12 26 1 Cassett e Motor 25 Motor Pl ug Intake 28 28 28 26 CO2 Disconnect 2 25 25 25 25 28 23 28 23 23 26 26 21 3 4 5 6 7 8 9 10 11 26 Inta ke Damper 4 Blk/Red Black/White White Black (High Speed) Red (Low Speed) Capa ...

  • Bard 920-0074 qwserv - page 11

    Manual 2100-533A Page 11 of 1 2 FIGURE 4 DISCONNECT & TAPE OFF WIRE DISCONNECT AND TAPE OFF FOR CO2 CONTROLLED VENTILATION MIS -2759 ...

  • Bard 920-0074 qwserv - page 12

    Manual 2100-533A Page 12 of 1 2 FIGURE 5 FIELD SET CO 2 SENSOR JUMPERS "AN" SET TO VOL TAGE "SW2 " SET TO ON "O U T" SE T T O 20- 100% AN OFF ON ON OFF 0-100% 20-100% VOLT AGE CURRENT OUT SW2 SW1 "SW1 " SET TO ON MIS-2756 QWSERV VENT PACKAG E CO 2 CONTR OLLER SETTIN G FOR 1000 PP M ...

メーカー Bard カテゴリー Ventilation Hood

Bard 920-0074 qwservのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 920-0074 qwservの取扱説明書
- Bardの製品カード
- パンフレット
- またはBard 920-0074 qwservの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bard 920-0074 qwservの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bard 920-0074 qwservの取り付け説明書、サービスマニュアル、簡易説明書、またはBard 920-0074 qwservのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bard 920-0074 qwservの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bard 920-0074 qwservデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBard 920-0074 qwservを使用するのを助ける技術的文書のことです。説明書は通常、全てのBard 920-0074 qwservユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bardの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bard 920-0074 qwservの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBard 920-0074 qwservの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bard 920-0074 qwservに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bard 920-0074 qwservデバイスの基本機能を使うにあたってのヒント。 Bard 920-0074 qwservのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bard 920-0074 qwservに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBard 920-0074 qwservのメーカー/サービスへの連絡先に関する情報。

Bard 920-0074 qwservについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBard 920-0074 qwservの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBard 920-0074 qwservで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)