    Instructions – Parts List ALUMINUM AND ST AINLESS STEEL Husky t 1590 Air-Operated Diaphragm Pumps 1.5–inch AODD pump for fluid transfer applications. For professional use only . See Models on page 2 for a list of pump models and descriptions. 120 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure 120 psi (0.8 MPa, 8 bar) Maximum Air Input Pres ...

  • Graco 308441ZAD - page 2

    2 308441 T able of Contents Models 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety W arnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Symbols 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Graco 308441ZAD - page 3

    308441 3 Symbols W arning Symbol W ARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. EQUIPMENT MISUSE HAZARD Equipment misuse can cause the ...

  • Graco 308441ZAD - page 4

    4 308441 TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.  Know the specific hazards of the fluid you are using.  Store hazardous fluid in an approved container . Dispose of hazardous fluid according to all local, state and national guidelines. ? ...

  • Graco 308441ZAD - page 5

    308441 5 Installation General Information  The typical installation shown in Fig. 2 is only a guide for selecting and installing system compo- nents. Contact your Graco distributor for assistance in planning a system to suit your needs.  Always use Genuine Graco Parts and Accessories. Refer to Product Data Sheet 305646.  Reference numbers ...

  • Graco 308441ZAD - page 6

    6 308441 Installation Mountings CAUTION The pump exhaust air may contain contaminants. V entilate to a remote area if the contaminants could af fect your fluid supply . See Air Exhaust V entilation on page 9. 1. Be sure the mounting surface can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation. 2. ...

  • Graco 308441ZAD - page 7

    308441 7 Installation Fluid Outlet Line W ARNING A fluid drain valve (J) is required to relieve pres- sure in the hose if it is plugged. The drain valve reduces the risk of serious injury , including splash- ing in the eyes or on the skin, or contamination from hazardous fluids when relieving pressure. Install the valve close to the pump fluid outl ...

  • Graco 308441ZAD - page 8

    8 308441 Installation Changing the Orientation of the Fluid Inlet and Outlet Ports The pump is shipped with the fluid inlet (R) and outlet (S) ports facing the same direction. See Fig. 3. T o change the orientation of the inlet and/or outlet port: 1. Remove the screws (106) holding the inlet (102) and/or outlet (103) manifold to the covers (101). 2 ...

  • Graco 308441ZAD - page 9

    308441 9 Installation Air Exhaust V entilation FIRE AND EXPLOSION HAZARD Be sure to read and follow the warnings and precautions regarding TOXIC FLUID HAZARD, and FIRE OR EXPLO- SION HAZARD on page 4, before op- erating this pump. Be sure the system is properly ventilated for your type of installation. Y ou must vent the exhaust to a safe place, aw ...

  • Graco 308441ZAD - page 10

    10 308441 Operation Pressure Relief Procedure PRESSURIZED EQUIPMENT HAZARD The equipment stays pressurized until pressure is manually relieved. T o reduce the risk of serious injury from pressurized fluid, accidental spray from the gun or splashing fluid, follow this procedure whenever you:  Are instructed to relieve pressure,  Stop pumping, ...

  • Graco 308441ZAD - page 11

    308441 1 1 Maintenance Lubrication The air valve is designed to operate unlubricated, however if lubrication is desired, every 500 hours of operation (or monthly) remove the hose from the pump air inlet and add two drops of machine oil to the air inlet. CAUTION Do not over-lubricate the pump. Oil is exhausted through the muffler , which could conta ...

  • Graco 308441ZAD - page 12

    12 308441 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10.  Relieve the pressure before checking or servicing the equipment.  Check all possible problems and causes before disassembling the pump. PROBLEM CAUSE SOLUTION Pump ...

  • Graco 308441ZAD - page 13

    308441 13 T roubleshooting PROBLEM CAUSE SOLUTION Fluid in exhaust air . Diaphragm ruptured. Replace. See pages 17–19. Loose diaphragm shaft bolt (107). T ighten or replace. See pages 17–19. Damaged o-ring (108). Replace. See pages 17–19. Pump exhausts excessive air at stall. Worn air valve block (7), o-ring (6), plate (8), pilot block (18), ...

  • Graco 308441ZAD - page 14

    14 308441 Service Repairing the Air V alve T ools Required  T orque wrench  T orx (T20) screwdriver or 7 mm (9/32 in.) socket wrench  Needle-nose pliers  O-ring pick  Lithium base grease NOTE: Air V alve Repair Kits 236273 (aluminum center housing models) and 255061 (sst center housing models) are available. Refer to page 23. Parts i ...

  • Graco 308441ZAD - page 15

    308441 15 Service 03270 Fig. 8 17  16 11 10  12 15 1 2 Insert narrow end first. Grease. 3 Install with lips facing narrow end of piston (1 1) . 4 Insert wide end first. 1 2 3 4 2 03271 1 2 8  9  3 Rounded side must face down (aluminum center housing mod- els only). T ighten screws until they bottom out on the housing. Fig. 9 1 ...

  • Graco 308441ZAD - page 16

    16 308441 Service Ball Check V alve Repair T ools Required  T orque wrench  13 mm socket wrench  O-ring pick Disassembly NOTE: A Fluid Section Repair Kit is available. Refer to page 23 to order the correct kit for your pump. Parts included in the kit are marked with an asterisk, for example (201*). Use all the parts in the kit for the best ...

  • Graco 308441ZAD - page 17

    308441 17 Service Diaphragm Repair T ools Required  T orque wrench  13 mm socket wrench  15 mm socket wrench (aluminum models) or 1 in. socket wrench (stainless steel models)  19 mm open–end wrench  O-ring pick  Lithium-base grease Disassembly NOTE: A Fluid Section Repair Kit is available. Refer to page 23 to order the correct k ...

  • Graco 308441ZAD - page 18

    18 308441 Service 4. Loosen but do not remove the diaphragm shaft bolts (107), using a 15 mm socket wrench (1 in. on stainless steel models) on both bolts. NOTE: This step does not apply to pumps with overmolded diaphragms. 5. Unscrew one bolt from the diaphragm shaft (24) and remove the o-ring (108), fluid side diaphragm plate (105), PTFE diaphrag ...

  • Graco 308441ZAD - page 19

    308441 19 Service 03275A 03274A Fig. 12 1 3 4 2 24 104 403* 401* 108* 107 24 24 104 401* 403* 107 105 19 402* Cutaway V iew , with Diaphragms in Place Cutaway V iew , with Diaphragms Removed 1 Lips face out of housing (1). Rounded side faces diaphragm (401). Air Side must face center housing (1). 1 Grease. Apply medium-strength (blue) Loctite  o ...

  • Graco 308441ZAD - page 20

    20 308441 Service Bearing and Air Gasket Removal T ools Required  T orque wrench  10 mm socket wrench  Bearing puller  O-ring pick  Press, or block and mallet Disassembly NOTE: Do not remove undamaged bearings. W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure R ...

  • Graco 308441ZAD - page 21

    308441 21 Service 03277 Fig. 13 1 3 2 25 23 22 1 19 15 12 16 H M Insert b earings tapered end first. Press-fit bearings flush with surface of center housing (1). Apply medium-strength (blue) Loctite  or equivalent. T orque to 130–150 in-lb (15–17 N  m). Detail of Air V alve Bearings 1 1 1 2 2 2 3 03278B 4 Muf fle r not included on Model N ...

  • Graco 308441ZAD - page 22

    22 308441 Pump Matrix Husky 1590 Aluminum and Stainless Steel Pumps, Series A Y our Model No. is marked on the pump’s serial plate. T o determine the Model No. of your pump from the following matrix, select the six digits which describe your pump, working from left to right. The first digit is always D , designating Husky diaphragm pumps. The rem ...

  • Graco 308441ZAD - page 23

    308441 23 Repair Kit Matrix For Husky 1590 Aluminum and Stainless Steel Pumps, Series A Repair Kits may be ordered separately . T o repair the air valve, order Part No. 236273 for aluminum center housing models or Part No. 255061 for stainless steel center housing models (see page 24). Parts included in the Air V alve Repair Kit are marked with a s ...

  • Graco 308441ZAD - page 24

    24 308441 Parts Drawing 1 Not used on some models. Aluminum Model Shown 2 Used on PTFE models only . * These parts are included in the Pump Repair Kit, which may be purchased separately . Refer to the Repair Kit Matrix on page 23 to determine the correct kit for your pump.  These parts are included in Air Valve Repair Kit 236273 (aluminum center ...

  • Graco 308441ZAD - page 25

    308441 25 Parts Air Motor Parts List (Matrix Column 2) Digit Ref. No. Part N o. Description Qty B 1 188838 HOUSING, center; aluminum 1 2 188854 COVER, air valve; aluminum 1 3 1 16344 SCREW , mach, hex flange hd; M5 x 0.8; 12 mm (0.47 in.) 9 4  188618 GASKET , cover; foam 1 5 188855 CARRIAGE; aluminum 1 6  108730 O-RING; nitrile 1 7 ? ...

  • Graco 308441ZAD - page 26

    26 308441 Parts Fluid Section Parts List (Matrix Column 3) Digit Ref. No. Part N o. Description Qty 3 101 15A615 COVER, fluid; aluminum 2 102 189402 MANIFOLD, inlet; aluminum 1 103 15A616 MANIFOLD, outlet; aluminum 1 104 15K448 PLA TE, air side; aluminum 2 105 189843 PLA TE, fluid side; carbon steel 2 106 1 15644 SCREW ; M10 x 1.25; 35 mm (1.38 in. ...

  • Graco 308441ZAD - page 27

    308441 27 Parts Seat Parts List (Matrix Column 4) Digit Ref. No. Part N o. Description Qty 3 201* 189318 SEA T ; 316 stainless steel 4 202* 1 12418 O-RING; PTFE 4 4 201* 189319 SEA T ; 17-4 stainless steel 4 202* 1 12418 O-RING; PTFE 4 5 201* 189322 SEA T ; TPE 4 202 None Not Used 0 6 201* 189320 SEA T ; Santoprene 4 202* 1 12418 O-RING; PTFE 4 7 2 ...

  • Graco 308441ZAD - page 28

    28 308441 T orque Sequence Always follow torque sequence when instructed to torque fasteners. 1. Left/Right Fluid Covers T orque bolts to 190–220 in–lb (22–25 N  m). SIDE VIEW 42 7 9 5 3 6 10 8 1 2. Inlet Manifold T orque bolts to 120–150 in–lb (14–17 N  m). BOTT OM VIEW 13 12 11 14 3. Outlet Manifold T orque bolts to 120–150 in ...

  • Graco 308441ZAD - page 29

    308441 29 Dimensions 5.23 in. (132.5 mm) 6.0 in. (152.5 mm) PUMP MOUNTING HOLE P A TTERN SIDE VIEW 1.5 npt(f) Outlet Port 6.0 in. (152.5 mm) 6.0 in. (152.5 mm) .45 in. (1 1.5 mm) 10.46 in. (265.5 mm) 45 ° 7438B 1.5 npt(f) Inlet Port 152.5 mm 38 mm FRONT VIEW 1/2 npt(f) Air Inlet 3/4 npt(f) Air Exhaust C B 268 mm 379.5 mm 197 mm A A B C 16.81 in. ( ...

  • Graco 308441ZAD - page 30

    30 308441 T echnical Data Maximum fluid working pressure 120 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (0.8 MPa, 8 bar) Air pressure operating range 20–120 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Graco 308441ZAD - page 31

    308441 31 Performance Chart 0 20 40 60 80 100 120 0 15 30 45 60 75 90 105 120 TEST CONDITIONS Pump tested in water with PTFE diaphragm and inlet submerged. (1 14) (170) (0.28, 2.8) (0.14, 1.4) (0.42, 4.2) KEY FLUID PRESSURE AND FLOW SCFM AIR CONSUMPTION Example of Finding Pump Air Consumption and Air Pressure at a Specific Fluid Delivery and Discha ...

  • Graco 308441ZAD - page 32

    32 308441 Graco W arranties Graco Standard Husky Pump W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a per ...

メーカー Graco カテゴリー Water Pump

Graco 308441ZADのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 308441ZADの取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco 308441ZADの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco 308441ZADの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco 308441ZADの取り付け説明書、サービスマニュアル、簡易説明書、またはGraco 308441ZADのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco 308441ZADの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco 308441ZADデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco 308441ZADを使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco 308441ZADユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco 308441ZADの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco 308441ZADの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco 308441ZADに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco 308441ZADデバイスの基本機能を使うにあたってのヒント。 Graco 308441ZADのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco 308441ZADに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco 308441ZADのメーカー/サービスへの連絡先に関する情報。

Graco 308441ZADについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco 308441ZADの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco 308441ZADで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)