Bloomfield WVG-136RWTの取扱説明書

30ページ 0.93 mb
ダウンロード

ページに移動 of 30

Summary
  • Bloomfield WVG-136RWT - page 1

    PRINTED IN UNITED ST A TES OF AMERICA WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P . O. Box 280 V erdi, NV 89439 www .wellsbloomfield.com telephone: 775-689-5703 fax: 775-689-5976 OPERA TION MANUAL WV G-136 SERIES GRIDDLE with UNIVERSAL HOOD MODELS: WVG-136 WVG-136R W WVG-136R WT Includes INST ALLA TION USE & CARE IMPORTANT: DO NOT DI SCARD THIS MANU ...

  • Bloomfield WVG-136RWT - page 2

    502 p/n 304986 OpM WVG-136 Ventless Grid dle Unless otherwise specified, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in ma terials and workmanship for a period of one year from the date of original installation or 18 months from the date of shipment from our factor y, whichever comes first, an ...

  • Bloomfield WVG-136RWT - page 3

    WARRANTY ................. .................................... ........... xi SPECIFICATIONS ........... .................................... ........ 1 FEATURES & OPERATING CONTROLS ................... 2 PRECAUTIONS & GENERAL INFO RMATION ........... 6 AGENCY LISTING INFORMATION .. ................. ......... 7 INSTALLATION ..... ........ ...

  • Bloomfield WVG-136RWT - page 4

    FEATURES & OPERATING CONTROLS Fig. 1 Ventilator Section Operating Features & Controls 2 28 28 19 16 23 a15 a1 1 53 56 18 9 8 38 VENTIL AT OR CONT ROL P ANEL see pa ges 4 & 5 GRIDDLE CONTROL P ANEL see page s 4 & 5 18 16 23 WARMER CONTROLS see pa ges 4 & 5 PULL HAN D LE TO ACTI VATE FIRE SU PPRESSION SYSTEM IN CA SE O F FIRE ANSU ...

  • Bloomfield WVG-136RWT - page 5

    ITEM 1. a6. 8. 9. a10. a11. 12. a15. 16. 18. 19. 22. 23. 28. a31. 38. 40. 41. 42. 43. 44. 53. 56. DESCRIPTION NAMEPLATE FIRE SUPPRESSION AGENT TANK (1.5 gal.) ADJUSTABLE (FRONT) LEG RIGID (REAR) CASTER MANUAL PULL STATION FUSIBLE LINKS LOWER REAR ACCESS PANEL DISCHARGE NOZZLE GREASE BAFFLE PRE-FILTER ASSEMBLY HEPA/CHARCOAL FILTER PACK GREASE CUP GR ...

  • Bloomfield WVG-136RWT - page 6

    FEATURES & OPERATING CONTROLS (continued) Fig. 2 Ventilator Section Controls & Indicator Lights Fig. 3 Griddle & Warmer Drawe r Operating Features & Controls 4 502 p/n 304986 OpM WVG-136 Ventless Grid dle GRIDDLE GREASE TROUGH GRIDDLE SURF ACE GREASE DRAWER OPTIONAL ROLL WARMER G.02 G.01 W .06 W .06 W .05 W .07 W .04 W .01 W .09 W . ...

  • Bloomfield WVG-136RWT - page 7

    ITEM V.01 V.02 V.03 V.04* V.05* V.06* G.01 G.02 W.01 W.02 W.03 W.04 W.05 W.06 W.07 W.08 W.09 DESCRIPTION POWER SWITCH POWER ON INDICATOR CHECK FILTERS ALARM INDICATOR REPLACE PREFILTER ALARM INDICATOR REPLACE FILTER PACK ALARM INDICATOR SERVICE REQUIRED ALARM INDICATOR GRIDDLE TEMPERATURE CONTROL INDICATOR LIGHT WARMER TEMPERATURE CONTROL POWER ON ...

  • Bloomfield WVG-136RWT - page 8

    NOTE: Fire suppression system and all associated comp onents must only be serviced by an authorized Ansu l® Distri butor. All setup, charging, repair and/or adjustment of th e fire sup pression system must be performed by an Authorized Ansul® Distributor ONLY . IMPORTANT: If a remote pull station is installed, both rea r casters (9) must be repla ...

  • Bloomfield WVG-136RWT - page 9

    AGENCY LISTING INFORMATION OPERATIONAL NOTES: REPLACE PREFILTER and REPLACE FILTER PACK indicator lights provide a timely warning that a system shut-down is i mminent. The actual time between the indicator li ght comin g on and the loss of cooking appliance power will depend upon the cooking conditions. Anytime a dirty PRE-FILTER is replaced, the s ...

  • Bloomfield WVG-136RWT - page 10

    INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual. WARNING: RISK OF INJURY Installation procedures mu st be performed by a qualified technician with full ...

  • Bloomfield WVG-136RWT - page 11

    SERVICE TECHNICIAN IN STALLATION NOTES An Ansul® technician must charge an d arm the fire suppression system before the ventilator blower will operate. See page 10 . Installation and start up must be performed by an Authorized Installation Company. Installer must complete the WARRANTY REGISTRATION form, and record appliance installation particular ...

  • Bloomfield WVG-136RWT - page 12

    INSTALLATION (continued) FIRE SUPPRESSION SYSTEM INSTALLATION 1. Any REMOTE MANUAL PULL STATION must b e installed by an authorized ANSUL® distributor in accordan ce with the AUTHORITY HAVING JURISDICTION. NOTE: If a REMOTE MANUAL PULL STAT ION is installed, moving the unit for servic ing will cause the Ansul® system to discharge. In this case, t ...

  • Bloomfield WVG-136RWT - page 13

    FILTERS INSTALLATION 1. FILTER PACK: Ships installed in the hood. If the FILTER PACK is not in position, the CHECK FILTERS indicator will light. If the FILTER PACK becomes clogged, the REPLACE FILTER PACK indicator will glow. To install the FILTER PACK: Position the filter pack with the charcoal portion UP. Slide the filt er pack toward the rear of ...

  • Bloomfield WVG-136RWT - page 14

    INSTALLATION (continued) WARNING SLIP / FALL HAZARD SPILLED OIL DO NOT OPERATE UNLESS THE GREASE CUP TROUGH AND GREASE DRAWER ARE INSTALLED. Oil and moisture will drip onto the floor and falls may result. Death or serious injury ma y result from slipping and falling GREASE TROUGH AND GREASE CUP INSTALLATION 1. Install the GREASE TROUGH into the bra ...

  • Bloomfield WVG-136RWT - page 15

    OPERATION CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. VENTILATOR OPERATION 1. Press the VENTILATOR POWER switch to ON. The green VENTILATOR POWER light will glow and the blower fan will start. After a short time, if all filters are sensed as being in position and not clogged, the griddle will be energized. The ...

  • Bloomfield WVG-136RWT - page 16

    OPERATION (continued) CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. As manufactured, the steel surface of your Wells griddle has microscopic pores. It is important to fill these pores with oil in order to provide a hard, non-stick cooking surface. Because the microscopic pores in the griddle surface are filled b ...

  • Bloomfield WVG-136RWT - page 17

    OPERATION (continued) CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. NOTE: The chart below is intended as a guide ONLY. Your own experience with this appliance, type of foods and method of operation will enable you to determine the temperature control and air vent settings best suited to your operation. DRAWER WA ...

  • Bloomfield WVG-136RWT - page 18

    OPERATION (continued) 16 ºF ºC LOAD PROCESS 3 2 5 1 4 RWT- CONTROL MOD ULE SET SETPOINT TEMPERATURE Press an arrow key: UP arrow to increase DO WN arrow to decrease Release key when desire d setpoint temperature is displayed. Reading is locked into memory 3 seco n ds after last key stro k e. Minimum setpoint is 140ºF (60ºC) Maximum setpoint is ...

  • Bloomfield WVG-136RWT - page 19

    17 CLEANING INSTRUCTIONS CAUTION: ELECTRIC SHOCK HAZARD Disconnect appliance from electric power before cleaning. CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool before cleaning. IMPORTANT: DO NOT spill or pour water into controls, control panel, wiring or coil-type hotplate elements. Damag ...

  • Bloomfield WVG-136RWT - page 20

    18 502 p/n 304986 OpM WVG-136 Ventless Grid dle CLEANING INSTRUCTIONS (continued) VENTILATOR WEEKLY CLEANING PREPARATION: Disconnect applian ce fro m electric power Allow to cool before cleaning FREQUENCY: Weekly TOOLS: Warm water and a mild detergent Soft clean cloth or sponge Bristle brush Container for disposal of grease 1. Remove the grease baf ...

  • Bloomfield WVG-136RWT - page 21

    CLEANING INSTRUCTIONS (continued) 19 CAUTION: ELECTRIC SHOCK HAZARD Disconnect appliance from electric power before cleaning. CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool before cleaning. IMPORTANT: Never allow PRE-FILTER or FILTER PACK to get wet. DO NOT wash either of these two filters ...

  • Bloomfield WVG-136RWT - page 22

    DRAWER WARMER DAILY CLEANING PRECAUTIONS: Turn control knob to OFF. Allow drawers to cool before proceeding. R e m o v e d r a w e r pans and Humitrol racks. FREQUENCY: Minimum -Daily TOOLS: Warm water and mild detergent Clean cloth or sponge 1. R emove drawe rs from warmer : a. Pull warmer drawer out until fully extended. b. Slide finger along lef ...

  • Bloomfield WVG-136RWT - page 23

    MAINTENANCE SCHEDULES USE AND MAINTENANCE SHALL BE IN ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS , N.F.P.A 17A & N.F.P.A. 96 (current editions). DANGER FIRE HAZARD FAILURE TO PROPERLY CLEAN AND MAINTAIN THIS EQUIPMENT CAN CAUSE A FIRE. AN UNCONTRO LLED FIRE CAN CAUSE SERIOUS INJURY, ...

  • Bloomfield WVG-136RWT - page 24

    22 WELLS BLOOMFIELD, LLC 502 p/n 304986 OpM WVG-136 Ventless Grid dle ...

  • Bloomfield WVG-136RWT - page 25

    23 WELLS BLOOMFIELD, LLC Replace two (2) fire suppression links at cooking appliance: each link is rated @ 212ºF Replace fire damper fusible link: rated @ 280ºF Max interval: 12 months 502 p/n 304986 OpM WVG-136 Ventless Grid dle ...

  • Bloomfield WVG-136RWT - page 26

    24 ANSU L ® ANSUL INCORPORA TED MAR I N ET T E, WI 541 43 - 25 42 MA TERIAL SAFETY D A T A SHEET ANSULEX L ow pH QUICK IDENT IFIER (In Plant C ommon Name) Manufa c turer’s Name: Eme rgenc y T elephone No.: ANSUL INCORP ORAT ED CHEMT REC (800) 424-9 300 or ( 70 3) 527-3 887 Prep ared By: Addres s : On e S tant on S treet, Mari ne t te , WI 5 414 ...

  • Bloomfield WVG-136RWT - page 27

    25 SECTION 5 - HEAL T H HAZ ARDS SECTION 6 - EMERGENCY AND FIRST AID PROC EDURES SECTIO N 7 - SPECIAL PROTECTIO N INFOR M A TION SECTIO N 8 - SPECIAL PRECAUT I ONS AND SPI LL/LEAK PR OCEDURES HAZARDOU S MA TERIAL IDENTIFI CA TION SYSTEM ANSU LEX Low p H (cont inued) Threshol d Limit V alue: Non e Est a bl is he d Routes of Entry: Eye Conta ct: Irri ...

  • Bloomfield WVG-136RWT - page 28

    TROUBLESHOOTING SUGGESTIONS SYMPTOM Ventilator blower won’t run Ventilator blower won’t run - buzzer sounding Ventilator blower runs momentarily, shuts down. CHECK FILTERS light on REPLACE PREFILTER light on. REPLACE FILTER PACK light on SERVICE REQUIRED light on Griddle won’t heat One or more griddle sections not hot enough Roll warmers won? ...

  • Bloomfield WVG-136RWT - page 29

    D E S C R I P T I O N S E R V I C E P A R T N O . PRE-FILTER 22618 PRE-FILTER CAGE 22683 FILTER PACK (HEPA + CHARCOAL) 22619 GREASE BAFFLE 22684 LEG KIT 22649 CASTER KIT 22650 GREASE CUP 22626 SCRAPER, GROOVED GRIDDLE 20651 DRAWER PAN, REPLACEMENT 21488 RACK, HUMITROL 20624 WELLS BULLETIN (ANSUL® PARTS LIST) 303331 NOTE: Ansul® Manual 418087 -05 ...

  • Bloomfield WVG-136RWT - page 30

    Genuine Parts Protect - YOU - All - W ays SER VICE TRAINING - QUALITY SER VICE SER VICE TRAINING - QUALITY SER VICE CUSTOMER SA TISF ACTION CUSTOMER SA TISF ACTION Commercial Food Equipment Service Association Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UNITED ST A TES OF AMERICA WELLS BLOOMFIELD ...

メーカー Bloomfield カテゴリー Griddle

Bloomfield WVG-136RWTのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- WVG-136RWTの取扱説明書
- Bloomfieldの製品カード
- パンフレット
- またはBloomfield WVG-136RWTの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bloomfield WVG-136RWTの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bloomfield WVG-136RWTの取り付け説明書、サービスマニュアル、簡易説明書、またはBloomfield WVG-136RWTのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bloomfield WVG-136RWTの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bloomfield WVG-136RWTデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBloomfield WVG-136RWTを使用するのを助ける技術的文書のことです。説明書は通常、全てのBloomfield WVG-136RWTユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bloomfieldの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bloomfield WVG-136RWTの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBloomfield WVG-136RWTの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bloomfield WVG-136RWTに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bloomfield WVG-136RWTデバイスの基本機能を使うにあたってのヒント。 Bloomfield WVG-136RWTのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bloomfield WVG-136RWTに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBloomfield WVG-136RWTのメーカー/サービスへの連絡先に関する情報。

Bloomfield WVG-136RWTについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBloomfield WVG-136RWTの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBloomfield WVG-136RWTで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)