National Instruments PXI Terminal Block NI TB-2708の取扱説明書

12ページ 0.87 mb
ダウンロード

ページに移動 of 12

Summary
  • National Instruments PXI Terminal Block NI TB-2708 - page 1

    INSTALLATION GUIDE NI TB-2708 PXI T erminal Block for S Seri es Devices This installation guide des cribes how to install and connect sig nals to the NI TB-2 708 terminal block for use with PXI-6115/ 6120 S Ser ies devi ces. Caution Th e connectors of the TB-2708 are sen sitiv e to electrostatic dischar ge (ESD). Th e user s hould grou nd thems elv ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 2

    NI TB-2708 I nstallation Guide 2 ni.com The nine SMB con nectors on the TB-2708 allow yo u to easily conn ect analog in put and analog ou tput signal s to you r Nation al Inst ruments de v ice. The 14-pin I/O connect or located on the bottom of the TB- 2708 allo ws access to digital signals. Caution Th e TB-2708 i s not des igned for i nput v oltag ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 3

    © Natio nal Instrum ent s Corpora tion 3 NI TB-2708 Inst alla tion Guide Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, d o not install unauthor ized parts or modify the device. Return the de vice to National Instru ments for service and re pair to ensure that its safety features are not co mp ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 4

    NI TB-2708 I nstallation Guide 4 ni.com T o conn ect the terminal block to the PXI module I/O connector , refer to Figure 2 as you complete the following steps: 1. Install the PXI module into the chass is and tighten the two module scre ws. Y ou must ins tall the PXI de vice before co nnecting the TB-2708. Refer to t he DAQ Getting Started Guide fo ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 5

    © Natio nal Instrum ent s Corpora tion 5 NI TB-2708 Inst alla tion Guide Figu re 4. NI TB -2708 B lock Dia gram For more detailed descriptions of these signals, refer to the S Series User Manual . Addit ion al s ign al co nfigur ati on in for m ation is av ailable in Measurement & Automation Explor er (MAX). T o acces s this information in MAX ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 6

    NI TB-2708 I nstallation Guide 6 ni.com Measuring F loatin g Signals You can use the TB-27 08 to measure floating and ground -referenced analog input signals. To measure floating signal sources, move the switch located under th e rubber-sealed doo r on the enclos ure cover for the AI channel you are using to the ON (floating source) switch position ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 7

    © Natio nal Instrum ent s Corpora tion 7 NI TB-2708 Inst alla tion Guide Cabling Options This section descr ibes the cabling op tions for accessing s ignals on the TB-2708. A 14-pin con nector on the bo ttom of the TB-2708 provide s access to digital I/O signals. Use the MFIT -Pigtail Cable Assem bly (part number 194123- 01) to access digital sig ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 8

    NI TB-2708 I nstallation Guide 8 ni.com T able 4 lists the National Instrum ents cables av ai lable for connecting the TB-2708 to both analog and dig ital user signals. 5 Orange P0.3 6 Blue CTR 0 O UT 7 White/Black GND 8 Red/Black P0.4 9 Green/Black P0.5 10 Orange/Black P0.6 11 Blue/Black P0.7 12 Drain W ire CHASSIS GN D 13 Red/W hite CTR 1 OUT 14 ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 9

    © Natio nal Instrum ent s Corpora tion 9 NI TB-2708 Inst alla tion Guide Specificatio ns This section lists the specificati ons of the TB -2708. Thes e specifications are typical at 25 °C unless otherwise specified. Inpu t/O utput Refer to the documentat ion for your PXI-6115/ 6120 S Ser ies device t o determine the inpu t/output specif ications ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 10

    NI TB-2708 I nstallation Guide 10 ni.com Environment The N I TB- 270 8 i s int ende d fo r ind oor use only . Operating temperature ...................... ......0 to 55 °C Storage temperature .......................... ......–20 to 70 °C Relative humidity . ........... ................. ......10 to 90% noncon densing Pollution Degree .......... ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 11

    © Natio nal Instrum ent s Corporati on 11 NI TB-2708 In stalla tion Gui de National Instrumen ts corporate headqu arters is located at 11500 Nor th Mopac Exp ressw ay , Austin, T exas, 787 59-3504. National Instruments also has of fi ces located ar ound the wo rld to hel p address your supp ort needs. For telephone s upport in the United States, c ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 12

    National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments C orporation. Refer to the Terms of Use section on ni.com/legal for more informa tion about N ational Instruments trademarks. Other product and company names ment ioned herein are trademarks or tr ade names of their respect ive companies. For patents covering Natio ...

メーカー National Instruments カテゴリー Network Card

National Instruments PXI Terminal Block NI TB-2708のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PXI Terminal Block NI TB-2708の取扱説明書
- National Instrumentsの製品カード
- パンフレット
- またはNational Instruments PXI Terminal Block NI TB-2708の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、National Instruments PXI Terminal Block NI TB-2708の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、National Instruments PXI Terminal Block NI TB-2708の取り付け説明書、サービスマニュアル、簡易説明書、またはNational Instruments PXI Terminal Block NI TB-2708のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、National Instruments PXI Terminal Block NI TB-2708の製品を使用するにあたって最も人気のある説明書を閲覧できます。

National Instruments PXI Terminal Block NI TB-2708デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNational Instruments PXI Terminal Block NI TB-2708を使用するのを助ける技術的文書のことです。説明書は通常、全てのNational Instruments PXI Terminal Block NI TB-2708ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

National Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. National Instruments PXI Terminal Block NI TB-2708の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNational Instruments PXI Terminal Block NI TB-2708の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。National Instruments PXI Terminal Block NI TB-2708に関してこのドキュメントで見つけることができる全てのヒントの目次
3. National Instruments PXI Terminal Block NI TB-2708デバイスの基本機能を使うにあたってのヒント。 National Instruments PXI Terminal Block NI TB-2708のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。National Instruments PXI Terminal Block NI TB-2708に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNational Instruments PXI Terminal Block NI TB-2708のメーカー/サービスへの連絡先に関する情報。

National Instruments PXI Terminal Block NI TB-2708についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNational Instruments PXI Terminal Block NI TB-2708の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNational Instruments PXI Terminal Block NI TB-2708で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)