  • Graco Inc. GC-1388G - page 1

    Operation Indy-X Chop GC-1388G ENG Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Low emission external-mix dispense gun for use with polyester resin and gel coat. For professional use only . Maximum fluid working pressure: 2000 psi (14 MP a, 138 bar) Maximum air pressure: 100 psi (0.7 MP a ...

  • Graco Inc. GC-1388G - page 2

    2 GC-1388F Contents W arnings .......................................................... 3 Important Safety Information ......................... 5 Grounding .............................................. .......... 6 Set-Up ............................................................... 7 P arts .................................................... ...

  • Graco Inc. GC-1388G - page 3

    3 GC-1388F W arnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure- specic risk. Refer back to these warnings. Additional, product-specic warnings may be found throughout the body of thi ...

  • Graco Inc. GC-1388G - page 4

    4 GC-1388F W ARNING SKIN INJECTION HAZARD High-pressure uid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not point gun at anyone or at any part of the body . • Do not put your hand over the dispens ...

  • Graco Inc. GC-1388G - page 5

    5 GC-1388F Important Safety Information Methyl Ethyl Ketone Peroxide (MEKP) MEKP is among the more hazardous materials found in commercial channels. Proper handling of the “unstable (reactive)” chemicals presents a denite challenge to the plastics industry . The highly reactive property which makes MEKP valuable to the plastics industry in p ...

  • Graco Inc. GC-1388G - page 6

    6 GC-1388F This equipment needs to be grounded. Ground the dispense gun through connection to a GlasCraft approved grounded uid supply hose. Check your local electrical code and related manuals for detailed grounding instructions of all equipment in the work area. A grounding wire and clamp are provided, assembly p/n 17440-00 with all FRP equipm ...

  • Graco Inc. GC-1388G - page 7

    7 GC-1388F Rotate trigger lock to stop the trigger from being activated. Hose Attachment 1. Engage the trigger lock. 2. Attach the (black p/n 21694-25) material hose to the material inlet tting on the back of the gun. 3. Attach the (yellow p/n 236) solvent line to the solvent inlet tting on the back of the gun. 4. Attach the (stainless steel ...

  • Graco Inc. GC-1388G - page 8

    8 GC-1388F Indy-X Chop Dispense Gun 23575-00 Repair Parts Kits: Part Number Description 23557-00 O-RING KIT 23558-00 MAINTENANCE KIT Standard Equipment Part Number Description 23575-00 Indy X Chop Dispense Gun GC-1388 User Manual P arts ...

  • Graco Inc. GC-1388G - page 9

    9 GC -1388F 1 2 3 1) Catalyst seat assembly p/n: 23544-00 2) Material seat assembly p/n: E-135 3) Material needle valve assembly p/n: 23545-00 23575-00 Indy X Chop Dispense Gun Assembly Drawings 189018 ...

  • Graco Inc. GC-1388G - page 10

    10 GC-1388F 23575-00 Indy X Chop Dispense Gun Note: Use p/n: LP A2-123S and p/n: LP A2-124S when using LP A2-147-XXXX and 23047-XX series spray tips. Assembly Drawings ...

  • Graco Inc. GC-1388G - page 11

    11 GC-1388F 23575-00 Indy X Chop Dispense Gun Assembly Drawings ...

  • Graco Inc. GC-1388G - page 12

    12 GC-1388F 23575-00 Indy X Chop Dispense Gun Assembly Drawings ...

  • Graco Inc. GC-1388G - page 13

    13 GC-1388F Part number Description Qty . 1 1021-41 PIPE PLUG 2 13076-06 O-RING 1 13867-03 O-RING 1 13867-05 O-RING 1 13867-07 O-RING 3 13867-09 O-RING 1 15845-01 BALL DRIVER 1 18383-02 1/4 IN. SST BALL 1 1880-00 FITTING 1 20506-00 NEEDLE 2 20507-00 P ACKING RET AINER 2 20508-00 MA TERIAL DISK 10 20509-00 P ACKING NUT 2 2051 1-00 NEEDLE COLLET 2 20 ...

  • Graco Inc. GC-1388G - page 14

    14 GC-1388F T o relieve uid and air pressures: 1. Push down Y ellow slide valve, P/N 21402-00 to bleed off air to system. 2. Open P/N 21228-00 on catalyst pump to recirculation position. 3. Open P/N 21 192-00 on bottom of material pump. 4. V erify the T rigger Lock is in the Locked position. Daily Maintenance It is recommended that the following ...

  • Graco Inc. GC-1388G - page 15

    15 GC-1388F Parts Replacement Procedure Before performing maintenance on the dispense gun, follow Pressure Relief Procedure. Due to the different o-ring materials and lubricants used in the dispense guns, never submerge or soak any dis - pense gun in any type of solvent. Submerging or soak - ing any dispense gun will immediately void the gun war- r ...

  • Graco Inc. GC-1388G - page 16

    16 GC-1388F 1 2 3 4 5 Needle & Pin Removal Procedures 1. Remove needle collets. (3/8in. Wrench) 2. Remove set screws. (5/64in. Hex Key) 3. Remove needle guard. 4. Remove pins. 5. Remove needle assemblies. (9/16in. Wrench) Maintenance ...

  • Graco Inc. GC-1388G - page 17

    17 GC-1388F 21222-00 20507-00 (Retainer) If Packing, P/N 20507-00 and Packing Disks, P/N 20508-00 are removed from Needle and Pack- ing Housing, GlasCraft recommends that these parts always be replaced with NEW packings and packing disks. 1. Ensure spring is seated on needle shoulder . 2. Insert needle into the packing housing . 3. Lubricate a te? ...

  • Graco Inc. GC-1388G - page 18

    18 GC-1388F OK OK 5 3 4 2 1 Flush Needle & Pin Reassemble Procedure 1. Reassemble the needle assemblies to the gun body . Lubricate the o-rings & use teon tape on the threads. 2. Make sure the gun pins are lubricated and slide them into the gun block and can be seen between the gun block and the back side of the trigger and they both are ...

  • Graco Inc. GC-1388G - page 19

    19 GC -1388F NOT OK Set Screws 5/64in. hex key T rigger & Needle Guard Readjustment Procedure If you trigger the gun and notice that one needle is activating before the other and not parallel, ne adjustment is needed. 1. Using a 5/64in. hex key adjust the Set Screw which is NOT making gun pin contact when the gun is triggered. T urn the set ...

  • Graco Inc. GC-1388G - page 20

    20 GC-1388F 1 Remove the trigger from gun. Slide it down and to the side. 2 Slide the gun pins, p/n 23514-00 forward to allow access to the packing nuts. 3 Adjust the packing nuts with a wrench. (3/8in. open end) Packing Nut Adjustment Procedure Maintenance ...

  • Graco Inc. GC-1388G - page 21

    21 GC-1388F Part Number Orice Min. Width (in.) Max. Width (in.) Min. Output (lbs.) Max Output (lbs.) 23005- C4 0.040 7 16.5 5.4 10.02 C5 0.050 8.5 15.5 6.36 12.23 C6 0.060 7 17 7.31 1 1.01 C7 0.070 7 13 8.53 10.58 C8 0.080 10 12.5 10.28 13.03 C9 0.090 7.5 10 1 1.49 12.36 E4 0.040 6 21 4.01 9.16 E5 0.050 11 21 5.71 10.23 E6 0.060 6.5 18.5 5.48 1 ...

  • Graco Inc. GC-1388G - page 22

    22 GC-1388F Impingement Dispense Tip Reference Chart Airless Dispense Tip Reference Chart Part Number Orice 23047-J1 .012 J2 .014 J3 .022 M1 .012 M2 .014 M3 .022 P1 .012 P2 .014 P3 .022 Note: Use p/n: LP A2-123S and p/n: LP A2-124S when using LP A2-147-XXXX and 23047-XX series spray tips. Part Number Orice LP A2-147-1525 0.015 1540 0.015 1550 ...

  • Graco Inc. GC-1388G - page 23

    23 GC-1388F T echnical Data Category Data Maximum Fluid Working Pressure 2000 psi (13.8 MPa, 138 bar) Maximum Air Inlet Pressure 100 psi (.69 MPa, 6.9 bar) T ypical Flow Rate of Pattern Guns Dependent of spray tip Maximum Fluid temperature 120° F (49° C) Air Inlet Size (Chopper) 1/4-18 NPS Male A Component (Catalyst) Inlet Size 1/4 in. T ube B Co ...

  • Graco Inc. GC-1388G - page 24

    Graco Ohio Standard W arranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a p ...

メーカー Graco Inc. カテゴリー Paint Sprayer

Graco Inc. GC-1388Gのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GC-1388Gの取扱説明書
- Graco Inc.の製品カード
- パンフレット
- またはGraco Inc. GC-1388Gの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco Inc. GC-1388Gの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco Inc. GC-1388Gの取り付け説明書、サービスマニュアル、簡易説明書、またはGraco Inc. GC-1388Gのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco Inc. GC-1388Gの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco Inc. GC-1388Gデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco Inc. GC-1388Gを使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco Inc. GC-1388Gユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Graco Inc.の取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco Inc. GC-1388Gの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco Inc. GC-1388Gの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco Inc. GC-1388Gに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco Inc. GC-1388Gデバイスの基本機能を使うにあたってのヒント。 Graco Inc. GC-1388Gのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco Inc. GC-1388Gに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco Inc. GC-1388Gのメーカー/サービスへの連絡先に関する情報。

Graco Inc. GC-1388Gについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco Inc. GC-1388Gの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco Inc. GC-1388Gで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください