  • Desa PH100EDI - page 1

    PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL PH150EDI 150,000 BTU/Hr IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. 150 SIDE PV 004 100 SIDE PV 002 PH100EDI 90,000 BTU/Hr PH30EDI 30,000 BTU/Hr PH70EDI 70,000 BTU/Hr ...

  • Desa PH100EDI - page 2

    2 099800 Flame-Out Information .................................................................. 3 Product Identification .................................................................... 4 Unpacking ...................................................................................... 5 Assembly ............................................... ...

  • Desa PH100EDI - page 3

    3 099800 ! W ARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of car ...

  • Desa PH100EDI - page 4

    4 099800 150,000 BTU/HR EURO PFA/PV 045 Fuel Cap Lower Shell Power Cord Upper Shell Figure 3 - 150,000 BTU/Hr Model 35/50/70,000 BTU/HR DOMESTIC PFA/PV 042 Handle Fuel Cap Lower Shell Side Cover Fuel Tank Figure 1 - 30/70,000 BTU/Hr Models Side Cover Fuel Tank Lower Shell Fuel Cap Fan Guard Power Cord Upper Shell PRODUCT IDENTIFICA TION Upper Shell ...

  • Desa PH100EDI - page 5

    5 099800 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y (For 90,000 and 150,000 BTU/Hr Models Only) These models are furnished with wheels and handles. Wheels, handles, and ...

  • Desa PH100EDI - page 6

    6 099800 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fi ne mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the combustion cham ...

  • Desa PH100EDI - page 7

    7 099800 VENTILA TION OPERA TION Continued Figure 6 - Flame-Out Control Reset Button, 30/70,000 BTU/Hr Models Figure 7 - Flame-Out Control Reset Button, 90,000 BTU/Hr Model ! W ARNING Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide ...

  • Desa PH100EDI - page 8

    8 099800 OPERA TION Continued Figure 8 - Flame-Out Control Reset Button, 150,000 BTU/Hr Model Continued PREVENT A TIVE MAINTENANCE SCHEDULE Item How Often How To Fuel tank Flush every 150-200 hours See Storage above. of operation or as needed. Air output and Replace every 500 hours of See Air Output, Air Intake , lint fi lters operation or once a ...

  • Desa PH100EDI - page 9

    9 099800 Continued Item How Often How To Spark plug Clean and regap every 600 See Spark Plug , pages 12 and 13. hours operation or replace as needed. Fan blades Clean every season or as needed. See Fan , page 19. Motor Not required/permanently lubricated. TROUBLE- SHOOTING OBSERVED FAULT POSSIBLE CAUSE REMEDY Wrong pump pressure Dirty air output, a ...

  • Desa PH100EDI - page 10

    10 099800 150 SHELL REMOVAL EA/EB Euro PV 020 Upper Shell Fan Guard Figure 12 - Fuel Filter Removal, 30/70,000 BTU/Hr Models Figure 11 - Upper Shell Removal, 150,000 BTU/Hr Model Figure 9 - Upper Shell Removal, 30/70,000 BTU/Hr Models Figure 10 - Upper Shell Removal, 90,000 BTU/Hr Model Upper Shell Fan Guard Fuel Filter Side Cover Fuel Line Fuel Fi ...

  • Desa PH100EDI - page 11

    11 099800 100 FUEL FILTER REMOVAL PFA/P 041 150 FUEL FILTER REMOVAL PFA/P 043 Fuel Filter (90,000 BTU/Hr Model) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel fi lter neck. 4. Carefully pry bushing, lower fuel line, and fuel fi lter out of fuel tank. 5. Wash fuel fi lter with clean ...

  • Desa PH100EDI - page 12

    12 099800 Spark Plug (30,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from nozzle assembly. 4. Remove spark plug wire from spark plug. 5. Remove two screws using 5/16" nut-driver and remove burner strap. 6. Place hex-body of spark plug into vise and tighten. 7. Remove spa ...

  • Desa PH100EDI - page 13

    13 099800 Spark Plug (70/90/150,000 BTU/Hr Models) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Clean and regap spark plug electrodes to 1.4 mm gap. 6. Install spark plug in burner head. 7. Attach spark plug wi ...

  • Desa PH100EDI - page 14

    14 099800 Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover. 4. Replace air output and lint fi lters. 5. Wash or replace air intake fi lter (see Preventative Maintenance Schedule, page 8). 6. Replace fi lter end cover. 7. Re ...

  • Desa PH100EDI - page 15

    15 099800 Nozzle (30,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from nozzle assem- bly. 4. Turn nozzle assembly 1/4 turn to left and pull toward motor to remove. 5. Place plastic hex-body into vise and lightly tighten. 6. Carefully remove nozzle from the nozzle adapter using ...

  • Desa PH100EDI - page 16

    16 099800 Nozzle (70/90,000 BTU/Hr Models) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using 5/16" nut-driver and remove burner head ...

  • Desa PH100EDI - page 17

    17 099800 Nozzle (150,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Loosen fl are nut using 3/4" open-end wrench. Push fuel tube down. 6. Remove air line hose from burner head. 7. Remove ...

  • Desa PH100EDI - page 18

    18 099800 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover and air fi lters. 4. Remove pump plate screws using 5/16" nut- driver. 5. Remove pump plate. 6. Remove rotor, insert, and blades. 7. Check for debris in pump. ...

  • Desa PH100EDI - page 19

    19 099800 Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 10). 2. Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft. 3. Slip fan off motor shaft. 4. Clean fan using a soft cloth moistened wi ...

  • Desa PH100EDI - page 20

    20 099800 WIRING DIAGRAMS Ignitor White Brown Blue Green/Yellow Photocell Spark Plug Flame- Out Control B Reset Button R Red Blue White Blue White Red Red Orange Terminal Board Motor Green/ Yellow Red Motor Start Relay Black S or 2 M or 3 L or 1 230V/50Hz Ignitor White Brown Blue Green/Yellow Photocell Spark Plug Flame- Out Control B Reset Button R ...

  • Desa PH100EDI - page 21

    21 099800 ASSEMBLY, EURO PFA/PV 018A 1 2 3 4 5 6 7 WHEELS AND HANDLES FOR 90,000 AND 150,000 BTU/Hr MODELS KEY PART PART 90,000 150,000 NO. NUMBER DESCRIPTION QTY. QTY. 1 HA2203 Handles 2 — HA2205 Handles — 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 8 3 M12342-3 Wheel Support Frame 1 — M12831-3 Wheel Support Frame — 1 4 NTC-3C Hex Nut, #10 ...

  • Desa PH100EDI - page 22

    22 099800 ILLUSTRA TED P ARTS BREAKDOWN 30,000 BTU/Hr 18-1 18-2 18-3 18-4 18-5 18-6 18-7 18-8 18-9 18-10 18-11 18-12 18-13 18-14 18-15 18-16 18-17 18-18 Motor and Pump Assembly 1 2 3 4 5 6 7 8 9 11 12 13 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 35 36 37 38 39 14 10 11-1 11-2 11-3 11-4 11-5 33 34 40 41 42 ...

  • Desa PH100EDI - page 23

    23 099800 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 30,000 BTU/Hr KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-173 Upper Shell 1 3 M1582 ...

  • Desa PH100EDI - page 24

    24 099800 ILLUSTRA TED P ARTS BREAKDOWN 70,000 BTU/Hr 18-1 18-2 18-3 18-4 18-5 18-7 18-8 18-9 18-10 18-11 18-12 18-14 18-15 18-16 18-18 18-17 18-6 PFA/P 007 MOTOR & PUMP 70 EAI/EBI 18-13 Motor and Pump Assembly BURNER HEAD 70 EAI/EBI PFA/P 018 10-1 10-2 10-3 10-4 10-5 10-7 10-6 Burner Head Assembly 1 2 4 3 5 6 7 8 10 11 12 12 14 15 16 (2) 17 20 ...

  • Desa PH100EDI - page 25

    25 099800 P ARTS LIST 70,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-173 Upper Shell 1 3 M1582 ...

  • Desa PH100EDI - page 26

    26 099800 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 (2) 17 18 19 20 25 26 29 30 31 32 33 34 35 36 37 38 39 40 41 6 42 43 21 22 23 24 45 44 27 28 46 PFA/P 010 MOTOR & PUMP 100 EAI/EBI ILLUSTRA TED P ARTS BREAKDOWN 90,000 BTU/Hr 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13-8 13-9 13-10 13-11 13-12 13-13 13-15 13-16 13-17 13-18 13-14 Motor and Pump Assembly B ...

  • Desa PH100EDI - page 27

    27 099800 P ARTS LIST 90,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-124 Upper Shell 1 2 M15823-27 Screw, #10-16 x ...

  • Desa PH100EDI - page 28

    28 099800 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 9 23 24 25 26 27 28 29 30 31 13 32 9 32 33 34 9 35 36 37 40 41 42 43 9 45 46 47 9 48 44 49 50 51 21 32 52 6 39 38 BURNER HEAD 150 EAI/EBI PFA/P 028 ILLUSTRA TED P ARTS BREAKDOWN 150,000 BTU/Hr 22-1 22-2 22-3 22-4 22-5 22-6 22-7 22-8 22-9 22-10 22-11 22-12 22-13 22-14 22-15 22-16 22-17 22 ...

  • Desa PH100EDI - page 29

    29 099800 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 150,000 BTU/Hr KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-175 Upper Shell 1 2 098068-01 Heat Deflector ...

  • Desa PH100EDI - page 30

    30 099800 ACCESSORIES Purchase accessories from your local dealer. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. For 30/70,000 BTU/Hr models. AIR GAUGE KIT - HA1180 For all models. Special tool to check pump pressure. STANDARD WHEELS AND HANDLE KIT - HA1206 Makes heater e ...

  • Desa PH100EDI - page 31

    31 099800 NOTES _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ ______________ ...

  • Desa PH100EDI - page 32

    32 099800 W ARRANTY AND REP AIR SERVICE IMPLIED WARRANTIES INCLUDING THOSE OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PUR- POSE ARE LIMITED TO THE DURATION OF THIS EX- PRESS WARRANTY. Any transportation charges, costs of installation, duty, taxes or any other charges whatsoever must be borne by the user. Power Tools S.A. ’ s obligation und ...

メーカー Desa カテゴリー Air Conditioner

Desa PH100EDIのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PH100EDIの取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa PH100EDIの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa PH100EDIの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa PH100EDIの取り付け説明書、サービスマニュアル、簡易説明書、またはDesa PH100EDIのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa PH100EDIの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Desa PH100EDIデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa PH100EDIを使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa PH100EDIユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa PH100EDIの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa PH100EDIの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa PH100EDIに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa PH100EDIデバイスの基本機能を使うにあたってのヒント。 Desa PH100EDIのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Desa PH100EDIに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDesa PH100EDIのメーカー/サービスへの連絡先に関する情報。

Desa PH100EDIについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDesa PH100EDIの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDesa PH100EDIで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)