  • Quatech QS-100D - page 1

    QS-100D Four Channel RS-232 Asynchronous Communications Adapter for ISA compatible machines User's Manual QUATECH, INC. TEL: (330) 655-9000 5675 Hudson Industrial Parkway FAX: (330) 655-9010 Hudson, Ohio 44236 http://www.quatech.com INTERFACE CARDS FOR IBM PC/AT AND PS/2 ...

  • Quatech QS-100D - page 2

    ...

  • Quatech QS-100D - page 3

    Warranty Information Quatech Inc. warrants the QS-100D to be free of defects for one (1) year from the date of purchase. Quatech Inc. will repair or replace any adapter that fails to perform under normal operating conditions and in accordance with the procedures outlined in this document during the warranty period. Any damage that results from impr ...

  • Quatech QS-100D - page 4

    © 1993, Quatech, Inc. NOTICE The information contained in this document cannot be reproduced in any form without the written consent of Quatech, Inc. Likewise, any software programs that might accompany this document can be used only in accordance with any license agreement(s) between the purchaser and Quatech, Inc. Quatech, Inc. reserves the righ ...

  • Quatech QS-100D - page 5

    Declaration of Conformity Manufacturer's Name: Quatech Inc. Manufacturer's Address: 5675 Hudson Industrial Parkway Hudson, Ohio 44 236 (USA) Application of Council Directive: 89/336/EEC Standards to which Conformity is Declared: * EN50081-1 (EN55022 , EN60 555-2 , EN6055 5-3) * EN50082-1 (IEC 801-2, IEC 801-3, & IEC 801-4) Type of Equ ...

  • Quatech QS-100D - page 6

    Table of Contents 6-1 6. Troubleshooting ......................................... 5-1 5. Specifications ............................................ 4-1 4. External Connections .................................... 3-3 3.2 Viewing and Changing Resources with Device Manager ................................ 3-1 3.1 Using the Add New Hardware Wizard . ...

  • Quatech QS-100D - page 7

    1. General Information The Quatech, Inc. QS-100D provides four RS-232 asynchronous serial communication interfaces for IBM-compatible personal computer systems using the 16-bit ISA (Industry Standard Architecture) expansion bus. The QS-100D is highly flexible with respect to addressing and interrupt level use. The serial ports are addressed in a co ...

  • Quatech QS-100D - page 8

    1.1.1 IND Package The IND upgrade on the QS-100IND and QS-100IND750 boards provides the protection essential for reliable use in an industrial environ ment. Special line drivers and receivers are used which have 15kV ESD (Electro Static Discharge) protection, and each communication line has a surge suppressor capable of sustaining up to 40A transie ...

  • Quatech QS-100D - page 9

    Figure 2 --- Diagram of QS-100D QS-100D User's Manual 1-3 ...

  • Quatech QS-100D - page 10

    (This Page Intentionally Left Blank) 1-4 Quatech Inc. ...

  • Quatech QS-100D - page 11

    2. Hardware Installation If the default address and interrupt settings are sufficient, the QS-100D can be quickly installed and put to use. The factory defaults are listed in Figure 3. 3 318 hex Serial 4 3 310 hex Serial 3 3 308 hex Serial 2 3 300 hex Serial 1 IRQ ADDRESS PORT Figure 3 --- Default address and IRQ settings for QS-100D The output of ...

  • Quatech QS-100D - page 12

    2.1 Setting the Base Address The base address of the QS-100D is set using the two DIP switch packs. When setting the address selection switches, a switch in the "ON" position specifies that the corresponding address line must be a logic 0 for the port to be selected. Similarly, a switch in the "OFF" position forces the correspon ...

  • Quatech QS-100D - page 13

    two, and one, hence the max im um value of 8+4+2+1 = 15. A serial port's address is a 16-bit quantity that is most of ten expres sed in four hex adecim al (base 16) digits. A hex digit can hold a value f rom 0 to 15 (decim al), and is made up of four binar y bits given weights of eight, four, A possible ser ial port address is 5220 hex. T he e ...

  • Quatech QS-100D - page 14

    2.2 Setting the Interrupt Level (IRQ) The QS-100D allows the use of any interrupt level in the range IRQ2 to IRQ7, IRQ10 to IRQ12, IRQ14, or IRQ15, selected using jumper pack J6. (Early versions of the QS-100D are limited to IRQ2-7.) In Figure 6 , the factory default setting of IRQ3 is shown. To select a different IRQ, move the jumper to the approp ...

  • Quatech QS-100D - page 15

    The QS-100D signals a hardware interrupt when any port requires service. The interrupt signal is maintained until no port requires service. Because the ISA bus is edge-sensitive, this behavior forces the interrupt service routine to ensure that all ports are checked before exiting. A way to do this is to poll each port until an interrupting port is ...

  • Quatech QS-100D - page 16

    Serial 1 --- 1 if interrupt pending 0 Serial 2 --- 1 if interrupt pending 1 Serial 3 --- 1 if interrupt pending 2 Serial 4 --- 1 if interrupt pending 3 0 (not used) 4 0 (not used) 5 0 (not used) 6 0 (not used) 7 (MSB) Figure 9 --- Interrupt Status Register contents 2-6 Quatech Inc. ...

  • Quatech QS-100D - page 17

    3. Windows 95 Configuration Windows 95 maintains a registry of all known hardware installed in your computer. Inside this hardware registry Windows 95 keeps track of all of your system resources, such as I/O locations, IRQ levels, and DMA channels. The "Add New Hardware Wizard" utility in Windows 95 was designed to add new hardware and up ...

  • Quatech QS-100D - page 18

    5. A list box opens with Manufacturers on the left and the associated board Models on the right. Click the “Have Disk” button. 6. An Install From Disk dialog box should pop up. Insert the diskette with the Quatech INF files on it, select the correct drive letter, and click the “OK” button. Windows 95 automatically browses the root directory ...

  • Quatech QS-100D - page 19

    12. You are required to manually configure the QS-100D to match the resources allocated by Windows 95. Another option is to use the “Device Manager” in Windows 95 to change the system resources allocated in Windows 95 to match your preferences. See chapter 2 for information on installing and configuring the QS-100D. 3.2 Viewing and Changing Res ...

  • Quatech QS-100D - page 20

    Figure 10--- Windows 95 Device Manager 6. If the “Change Settings” button was selected an Edit Resource window will open up. Inside these Edit Resource windows click on the up/down arrows to the right of the resource value. This scrolls you through all of the allowable resources for your hardware. Pay attention to the Conflict Information at th ...

  • Quatech QS-100D - page 21

    which allows the ports UART compatibility mode and FIFO levels to be configured. Note that FIFO option for each of the four ports QS-100D ports is configured independently. Figure 11 --- Windows 95 Device Manager 10. Use the Logical COM Ports numbers to access the serial ports on your QS-100D through your software applications. Note: The Logical CO ...

  • Quatech QS-100D - page 22

    (This Page Intentionally Left Blank) 3-6 Quatech Inc. ...

  • Quatech QS-100D - page 23

    4. External Connections RS-232-C devices are classified by their function as either Data Terminal Equipment (DTE) or Data Communication Equipment (DCE). Generally, data terminal equipment is defined as the communication source and data communication equipment is defined as the device that provides a communication channel between two DTE-type device ...

  • Quatech QS-100D - page 24

    The QS-100D connects to peripheral equipment through a single female D-37 connector, or using the adapter cable, four male D-25 connectors. The standard serial port connections are listed in Figure 14 . 7 35 7 12 7 26 7 3 GND 22 15 22 29 22 6 22 20 RI 8 34 8 11 8 25 8 2 DCD 6 17 6 31 6 8 6 22 DSR 20 16 20 30 20 7 20 21 DTR 5 36 5 13 5 27 5 4 CTS 4 ...

  • Quatech QS-100D - page 25

    5. Specifications Bus interface: Industry Standard Architecture (ISA) 16-bit bus IBM PC-AT TM compatible Dimensions: 6.65" x 3.7" Serial ports Controller: 16550 (16750 optional) Interface: One female D-37 connector Four male D-25 connectors using adapter cable Transmit drivers: MC1488 or compatible High level output: +9V min, +10.5V max L ...

  • Quatech QS-100D - page 26

    (This Page Intentionally Left Blank) 5-2 Quatech Inc. ...

  • Quatech QS-100D - page 27

    6. Troubleshooting Listed here are some common problems and frequent causes of those problems. Suggestions for corrective action are given. If the information here does not provide a solution, contact Quatech Customer Service for technical support. Any unauthorized repairs or modifications will void the QS-100D's warranty. Computer will not bo ...

  • Quatech QS-100D - page 28

    (This Page Intentionally Left Blank) 6-2 Quatech Inc. ...

  • Quatech QS-100D - page 29

    ...

  • Quatech QS-100D - page 30

    QS-100D User's Manual Revision 3.11 March 2004 P/N: 940-0022-311 ...

メーカー Quatech カテゴリー Network Cables

Quatech QS-100Dのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- QS-100Dの取扱説明書
- Quatechの製品カード
- パンフレット
- またはQuatech QS-100Dの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Quatech QS-100Dの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Quatech QS-100Dの取り付け説明書、サービスマニュアル、簡易説明書、またはQuatech QS-100Dのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Quatech QS-100Dの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Quatech QS-100Dデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがQuatech QS-100Dを使用するのを助ける技術的文書のことです。説明書は通常、全てのQuatech QS-100Dユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Quatechの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Quatech QS-100Dの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははQuatech QS-100Dの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Quatech QS-100Dに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Quatech QS-100Dデバイスの基本機能を使うにあたってのヒント。 Quatech QS-100Dのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Quatech QS-100Dに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるQuatech QS-100Dのメーカー/サービスへの連絡先に関する情報。

Quatech QS-100Dについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもQuatech QS-100Dの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがQuatech QS-100Dで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)