Lennox Hearth Products Cambriaの取扱説明書

26ページ 2.32 mb
ダウンロード

ページに移動 of 26

Summary
  • Lennox Hearth Products Cambria - page 1

    Wood-Burning Fireplace P/ N 8 50 ,0 57 M R EV . C 1 1/ 20 08 CAMBRIA MODEL CAMBRIA™ This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation or operating the fireplace. CAUTION: Do not alter or modi ...

  • Lennox Hearth Products Cambria - page 2

    2 W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. CAUTION NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flamm ...

  • Lennox Hearth Products Cambria - page 3

    THE FIREPLACE INTRODUCTION The Cambria™ wood-burning fireplace is a mid-efficient, heat radiating fireplace. Y ou will receive a lifetime of comfort and enjoyment from your fireplace provided it is installed, maintained and operated properly . • Please read these instructions and retain this manual for future reference. • Before beginning ...

  • Lennox Hearth Products Cambria - page 4

    Accelerated Combustion The maximum heat output for the Cambria fireplace is achieved by burning with the door closed and the combustion air opened. How- ever , it will be necessary to reload with wood every hour . This is the least efficient method of burning the Cambria fireplace . Use caution when burning with the combustion air control wide o ...

  • Lennox Hearth Products Cambria - page 5

    Building a Fire A) T o start a fire, place several crumpled up balls of newsp aper in the firebox. Place small dry pieces of kindling on top of the paper , criss-crossing the kindling so that there are air spaces in between. The kindling should be placed at the center of the firebox so as to allow for sufficient air circulation. B) Open the dam ...

  • Lennox Hearth Products Cambria - page 6

    IMPORT ANT CAUTIONS A. Do not block the hot air vents to the fire- place as this will cause the fireplace to overheat. B. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or ‘freshen up’ a fire in this fireplace. Keep all such liquids well away from the fireplace while it is in ...

  • Lennox Hearth Products Cambria - page 7

    Figure 6 The gaskets’ air -tightness can be adjusted us- ing the adjustment screw located on the slider stoppers (see Figure 8 ) . T urning the screws clockwi se will shorten the travel of the slider and increase the pressure on the door side gaskets. This may lead to the doors being harder to lock, so a good adjustment must be found between a go ...

  • Lennox Hearth Products Cambria - page 8

    Gasket Part # Dimensions Qty Around the door PR-SR1823N 58-3/4” 5/8” dia. 2 T able 1 Figure 10 Figure 11 Unscrew the nuts to change the bearings Door Angle (hang) Adjustment Screw NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 8 GLASS CARE Glass Replacement The glass used for the Cambria™ fireplace is a high temperature ceramic glass ...

  • Lennox Hearth Products Cambria - page 9

    FIREPLACE INST ALLA TION Locating The Fireplace The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the loca- tion of the ...

  • Lennox Hearth Products Cambria - page 10

    Figure 14 - Hearth Extension and Clearances Fireplace Figure 13 - Hearth Extension Requirements Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations ( Figures 15 through 20 ): A. Frame the fireplace using 2” x 3” or heavier lumber . B. WARNING: ...

  • Lennox Hearth Products Cambria - page 11

    No t es Due to Lenn ox Hear th Prod uc ts ongo ing com mit me nt to qual it y , all spec ifi cat io ns, rat ing s and dime nsi on s are s ubj ec t t o cha ng e w it hou t not ic e. All fram in g dime ns ion s cal cul at ed for 1/2 " dry wall at the fir ep lac e f ac e. If she at hin g t he ch ase or fin ish - ing with othe r thi ck nes s ma ...

  • Lennox Hearth Products Cambria - page 12

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 12 Figure 16 Insulated Chase Construction Floor Ceiling Wall • Must have the same firestopping resistance as adjacent wall. • Must have the same insulation as adjacent ceiling. • Follow local rules regarding framing construction. Note: Floor and wall below the attic must be insulated using ...

  • Lennox Hearth Products Cambria - page 13

    1. Combust ible material must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) (see Figure 19 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing (see Figure 20 ) . MANTEL AND F ACING The ma ...

  • Lennox Hearth Products Cambria - page 14

    Figure 23 Figure 21 HOT AIR DUCTING INST ALLA TION (OPTIONAL) Diff eren t hot air ducti ng system s can be install ed with the Cambria™ fireplace: • Gravity kit • Forced air kit The gravity kit is used when the rooms are on same level or floor as the firep lace or on an upper level or floor . If the heat to be distributed is on a lower le ...

  • Lennox Hearth Products Cambria - page 15

    Figure 24 Figure 25 Aluminum T ape Insulation Blower Tightening Collar Flex 5” Diameter Adaptor Insulated Flex Pipe B) Attach the 5” flexible pipe, using the collars provided. Important: Make sure that the plastic wrapping around the flexible pipe will not be in contact with the fireplace. C) Route the flexible pipe to the chosen location. ...

  • Lennox Hearth Products Cambria - page 16

    OUTSIDE CONNECTION Outside Intake Screw Opening Facing Down Wall Aluminum T ape Plastic Cover Insulation Flexible Pipe Aluminum T ape OUTSIDE AIR It is mandator y to install an outside air connec- tion to the Cambria™ fireplace. The following components are required and are included with the fireplace: • Outside air kit • 4” adapter for ? ...

  • Lennox Hearth Products Cambria - page 17

    Figure 28 THE CHIMNEY SYSTEM Chimney Installation Notes 1. If possible, install an interior chimney as it will provide better per formance. In areas with continuous temperatures below 0°F (18°C), the use of an exterior chimney in- creases the likelihood of operating problems such as low draft, high rate of creosoting, and poor start-up characteri ...

  • Lennox Hearth Products Cambria - page 18

    Figure 31 Flashing Attic Radiation Shield Firestop Universal Support AC Starter Section AC10SB or AC10SB30 Note: Outside air kits must be installed for both fireplace and AC chimney . Ou ts id e Co mb us tio n Ai r Ki t From below, install a firestop in each ceiling/ floor separation through which the chimney will pass. At the attic level, insta ...

  • Lennox Hearth Products Cambria - page 19

    Roof Down Slope Hole Size D e gr e e O f S l o pe S e cu r e T em p AS HT + N o va T e m p HT 61 03 + A C R o of P i tc h 1 0 ” 10 ” 0 * 1 6 -3 / 8 ” ( 4 16 m m) 1 7 ” ( 4 32 m m) 2 / 12 1 6 - 5/ 8 ” ( 4 2 2 m m ) 1 7 -1 / 4 ” ( 4 38 m m) 4 / 12 1 7 - 1/ 4 ” ( 4 3 9 m m ) 1 8 ” ( 4 57 m m) 6 / 12 1 8 - 3/ 8 ” ( 4 6 6 m m ) 1 9 ” ...

  • Lennox Hearth Products Cambria - page 20

    C h i mn ey Elbow Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48” 8” & 48” 1 2 ” & 4 8 ” 18 ” & 4 8” 24 ” & 48 ” 36” & 48” 48” & 48” AS HT + HT 61 03 + 10 ” 15º A 3” (7 6mm ) 4- 1/4 ” (1 08m m ) 5- 3/4 ” (1 46m m ) 7- 1/4 ” (1 84m ...

  • Lennox Hearth Products Cambria - page 21

    Figure 35 OFFSET CHIMNEY INST ALLA TION Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 36 Roof Support Note: In cold areas it is recommended to protect the chimney in a insulated chase. Outside Wall OFFSET CHIMNEY INST ALLA TION WITH WALL PENETRA TION IF THE CEILING IS 9 FEET OR LESS THIS INS ...

  • Lennox Hearth Products Cambria - page 22

    RSMI30, RSMI45, AC10RSMI30 Ch im ne y ( 10 ” di a. ) Angle Hole Dimension Secure T emp ASHT+ Nova T emp HT6103+ 30º 17 -9 /1 6” x 45 - 3/ 4” ( 44 6 m m x 11 62 m m) Secure T emp ASHT+ Nova T emp HT6103+ 45º Canada only 17 -1 /2 ” x 3 0” (4 44 m m x 7 62 mm ) AC 30º 17 ” x 42 - 1/ 2” (4 32 m m x 10 80 m m) T able 5 Figure 37 Drywall ...

  • Lennox Hearth Products Cambria - page 23

    Installation Accessories Description Cat./Part No. Outside Air Kit (included with fireplace) Outside air kit, UZI UZI UZ I ou ts i de a ir k it fi re pl ac e ad ap to r , UZ IA D UZ IA D Gravity Kit G ra vi ty Ki t , Co m p l et e do ub l e du c t i n g sy s t em in cl u d i n g: 2 e lb ow s 90 º, 2 t el es co p ic l en g t hs , 2 g r i ll s u p ...

  • Lennox Hearth Products Cambria - page 24

    CHIMNEY - P ARTS AND COMPONENTS LISTS S e c u r e T em p A S HT + 1 ” H i g h T em p. I ns ul a t ed St a i nl e s s S te e l C h im n e y 10” I.D., Double-Wall Stainless Steel, Listed to CAN/UCL-S604 & UL-103HT Description Part/Cat. No. Lengths and Misc. Chimney Components 8” length, 10” Dia., 10L8-N 10L8-N 12” length, 10” Dia., 10 ...

  • Lennox Hearth Products Cambria - page 25

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: • Side wall (fireplace front): 24” (457 mm) measured from the fireplace door . • Ceiling: 7’ 6” (2286 mm) measured from the base of the fireplace • Fireplace enclosure: Bottom: 0” Side: 0” to spacer Back: 0” to spacer T op: ...

  • Lennox Hearth Products Cambria - page 26

    Printed in Canada © 2008 by Lennox Hearth Products P/N 850,057M REV . C 11/2008 Lennox Hearth Products reser ves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. 1110 West T aft Av ...

メーカー Lennox Hearth Products カテゴリー Indoor Fireplace

Lennox Hearth Products Cambriaのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Cambriaの取扱説明書
- Lennox Hearth Productsの製品カード
- パンフレット
- またはLennox Hearth Products Cambriaの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lennox Hearth Products Cambriaの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lennox Hearth Products Cambriaの取り付け説明書、サービスマニュアル、簡易説明書、またはLennox Hearth Products Cambriaのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lennox Hearth Products Cambriaの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Lennox Hearth Products Cambriaデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLennox Hearth Products Cambriaを使用するのを助ける技術的文書のことです。説明書は通常、全てのLennox Hearth Products Cambriaユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lennox Hearth Productsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lennox Hearth Products Cambriaの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLennox Hearth Products Cambriaの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lennox Hearth Products Cambriaに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lennox Hearth Products Cambriaデバイスの基本機能を使うにあたってのヒント。 Lennox Hearth Products Cambriaのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lennox Hearth Products Cambriaに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLennox Hearth Products Cambriaのメーカー/サービスへの連絡先に関する情報。

Lennox Hearth Products Cambriaについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLennox Hearth Products Cambriaの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLennox Hearth Products Cambriaで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)