Omega Engineering OMG-COMM2-EXの取扱説明書

22ページ 0.26 mb
ダウンロード

ページに移動 of 22

Summary
  • Omega Engineering OMG-COMM2-EX - page 1

    www .omega.com e-mail: info@omega.com U ser ’ s Guide OMG-COMM2-EX Dual Por t ISA RS-232/422/485 Inter face Board Shop online at ...

  • Omega Engineering OMG-COMM2-EX - page 2

    Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sale ...

  • Omega Engineering OMG-COMM2-EX - page 3

    Contents I NTRODUCTION ..........................................................................1 O VERVIEW ................................................................................................ 1 W HAT ’ S I NCLUDED ................................................................................ 1 F ACTORY D EFAULT S ETTINGS ......... ...

  • Omega Engineering OMG-COMM2-EX - page 4

    RS - 232 ..................................................................................................... 12 RS - 422 ..................................................................................................... 12 RS - 485 ..................................................................................................... 13 A PPENDI ...

  • Omega Engineering OMG-COMM2-EX - page 5

    Introduction OMG - COMM2 - EX Page 1 Introduction Overview The OMG - COMM2 - EX provides the PC with 2 asynchronous serial ports providing a versatile interface field selectable as RS - 232 for modems, printers and plotters, as well as RS - 422/485 for industrial automation a nd control applications. What’s Included The OMG - COMM2 - EX is shippe ...

  • Omega Engineering OMG-COMM2-EX - page 6

    Card Setup OMG - COMM2 - EX Page 2 Card Setup The OMG - COMM2 - EX contains several jumper straps which must be set for proper operation. Addres s Selection Each port on the OMG - COMM2 - EX occupies eight consecutive I/O locations. A DIP - switch is used to set the base address for these locations. Be careful when selecting the base address as som ...

  • Omega Engineering OMG-COMM2-EX - page 7

    Card Setup OMG - COMM2 - EX Page 3 Port Enable / Disable Each port on the OMG - COMM2 - EX can be enabled or disabled with switch position 8 on the DIP - switch. The port is enabled with the switch ‘On’ or ‘Closed’ and disabled when ‘Off’ or ‘Open’. If any port is disabled, be sure to disable the interrupt request for that port by r ...

  • Omega Engineering OMG-COMM2-EX - page 8

    Card Setup OMG - COMM2 - EX Page 4 Interrupt Modes Headers E9 and E10 select the interrupt modes for each port. Each port must be set in the correct mode to insure proper installation. E10 sets Port 1 and E9 sets Port 2 ‘ N ’ indicates the ( N )ormal, single interrupt per port mode. ‘ S ’ Indicates the ( S )hared interrupt mode, wh ich allo ...

  • Omega Engineering OMG-COMM2-EX - page 9

    Card Setup OMG - COMM2 - EX Page 5 Set the jumper to ‘ S ’ if you are usin g more than one OMG - COMM2 - EX in a bus or you wish to completely remove the pull - down resistor for hardware compatibility. Setting the adapter in this configuration when it is not accompanied by a pull - down resistor will prevent the ports from triggering an interr ...

  • Omega Engineering OMG-COMM2-EX - page 10

    Installation OMG - COMM2 - EX Page 6 Installation The OMG - COMM2 - EX can be installed in any of the PC expa nsion slots, but to access the ‘AT’ or (E)ISA IRQs (10 - 15) it must be installed in one of the 16 bit slots. The OMG - COMM2 - EX contains several jumper straps for each port which must be set for proper operation prior to installing t ...

  • Omega Engineering OMG-COMM2-EX - page 11

    Technical Description OMG - COMM2 - EX Page 7 Technical Description The OMG - COMM2 - EX adapter utilizes the 16550 UART chip. This chip features programmable baud rate, data format, interrupt control and has a 16 byte transmit and receive FI FO. Features • Full independent operation of ports allowing two ports RS - 232, two ports RS - 422/485 or ...

  • Omega Engineering OMG-COMM2-EX - page 12

    Technical Description OMG - COMM2 - EX Page 8 Connector Pin Assignments RS - 232 (Male DB9) Name Pin # Mode TD Transmit Data 3 Output RTS Request To Send 7 Output DTR Data Term Ready 4 Output GND Ground 5 RD Receive Data 2 In put DCD Data Carrier Detect 1 Input DSR Data Set Ready 6 Input CTS Clear To Send 8 Input RI Ring Indicator 9 Input Note: The ...

  • Omega Engineering OMG-COMM2-EX - page 13

    Specifications OMG - COMM2 - EX Page 9 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) - 20º to 70º C (- 4º to 158º F) Humidity Rang e 10 to 90% R.H. Non - Condensing 10 to 90% R.H. Non - Condensing Manufacturing • IPC 610 - B Class - III standards are adhered to wi ...

  • Omega Engineering OMG-COMM2-EX - page 14

    Appendix A - Troubleshooting OMG - COMM2 - EX Page 10 Appendix A - Troubleshooting Serial Utility test software is supplied wit h the adapter and will be used in the troubleshooting procedures. By using this software and following these simple steps, most common problems can be eliminated without the need to call Technical Support. 1. Identify all ...

  • Omega Engineering OMG-COMM2-EX - page 15

    Appendix B - How To Get Assistance OMG - COMM2 - EX Page 11 Appendix B - How To Get Assistance Please refer to Troubles hooting Guide prior to calling Technical Support. 1. Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed please see below. 2. When calling for technical assistance, please have your use ...

  • Omega Engineering OMG-COMM2-EX - page 16

    Appendix C - Electrical Interface OMG - COMM2 - EX Page 12 Appendix C - Electrical Interface RS - 232 Quite possibl y the most widely used communication standard is RS - 232. This implementation has been defined and revised several times and is often referred to as RS - 232 or EIA/TIA - 232. The IBM PC computer defined the RS - 232 port on a 9 pin ...

  • Omega Engineering OMG-COMM2-EX - page 17

    Appendix C - Electrical Interface OMG - COMM2 - EX Page 13 RS - 485 RS - 485 is backwardly compatible with RS - 422; however, it is optimized for partyline or multi - drop applications. The output of the RS - 422/485 driver is capable of being Active (enabled) or Tri - State (disabled). This capability allows multiple ports to be connected in a mul ...

  • Omega Engineering OMG-COMM2-EX - page 18

    Appendix D - Asynchronous Communications OMG - COMM2 - EX Page 14 Appendix D - Asynchronous Communications Serial data co mmunications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data rate, error checking, handshaking, and character framing (start/stop bits) ...

  • Omega Engineering OMG-COMM2-EX - page 19

    Appendix E - Silk - Screen OMG - COMM2 - EX Page 15 Appen dix E - Silk - Screen 3.9" 6.9" 4.2" ...

  • Omega Engineering OMG-COMM2-EX - page 20

    Appendix F - Compliance Notices OMG - COMM2 - EX Page 1 6 Appendix F - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the F CC Rules. These limits are designed to provide reasonable protection against harmful i ...

  • Omega Engineering OMG-COMM2-EX - page 21

    W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E G A ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time. This ensures that OME GA ? ...

  • Omega Engineering OMG-COMM2-EX - page 22

    M1691/0303 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, C ...

メーカー Omega Engineering カテゴリー Switch

Omega Engineering OMG-COMM2-EXのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- OMG-COMM2-EXの取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering OMG-COMM2-EXの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering OMG-COMM2-EXの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering OMG-COMM2-EXの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering OMG-COMM2-EXのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering OMG-COMM2-EXの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering OMG-COMM2-EXデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering OMG-COMM2-EXを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering OMG-COMM2-EXユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering OMG-COMM2-EXの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering OMG-COMM2-EXの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering OMG-COMM2-EXに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering OMG-COMM2-EXデバイスの基本機能を使うにあたってのヒント。 Omega Engineering OMG-COMM2-EXのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering OMG-COMM2-EXに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering OMG-COMM2-EXのメーカー/サービスへの連絡先に関する情報。

Omega Engineering OMG-COMM2-EXについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering OMG-COMM2-EXの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering OMG-COMM2-EXで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)