Emerson Process Management TF396の取扱説明書

20ページ 0.45 mb
ダウンロード

ページに移動 of 20

Summary
  • Emerson Process Management TF396 - page 1

    COMBINA TION pH SENSOR Instruction Manual PN 51-TF396/rev .G June 2012 MODEL TF396 with mating cable Model TF396 ...

  • Emerson Process Management TF396 - page 2

    CAUTION SENSOR/PROCESS APPLICA TION COMP A TIBILITY The wetted sensor materials may not be comp atible with process com position and operating conditions. Application comp at ibility is entirely the responsibility of the user . DANGER HAZARDOUS AREA INST ALLA TION This sensor is not Intrinsically Safe. or Explosion Proof. Installations near flammab ...

  • Emerson Process Management TF396 - page 3

    i MODEL TF396 T ABLE OF CONTENTS MODEL TF396 COMBINA TION pH SENSOR T ABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICA TIONS ................................................................. 1 1.1 Features and Applications ........................................................................................ 1 1.2 S pecifications ...

  • Emerson Process Management TF396 - page 4

    MODEL TF396 T ABLE OF CONTENTS LIST OF FIGURES Number Title Page 2-1 Dimensional Drawing ............................................................................................... 4 2-2 Flow-Through T ee with Adapter ................................................................................ 4 2-3 Flow-Through and Insertion Installations ...

  • Emerson Process Management TF396 - page 5

    greater than typical teflon or ceramic junctions) is made of micron-sized reference pathways allowing for ionic exchange but preventing plugging by larger particles and will continue to send a steady pH signal, even in the dirtiest of applications. The field-proven TUpH reference junction tech- nology results in greatly reduced maintenance requirem ...

  • Emerson Process Management TF396 - page 6

    MODEL TF396 SECTION 1.0 DESCRIPTIONS AND SPECIFICA TIONS The Model TF396 TUpHFET Non-glass ISFET pH Sensor is housed in a molded reinforced polypropylene body with 1 in. MNPT threads suit able for insertion, submersion or flow through installation, or housed in a 316SST body for use with a 2.0 inch T ri-Clamp fitting. The sensor includes an ion-sel ...

  • Emerson Process Management TF396 - page 7

    3 MODEL TF396 SECTION 2.0 INST ALLA TION SECTION 2.0 INST ALLA TION In most cases, the pH sensor can simply be installed as shipped and readings with an accuracy of ± 0.6 pH may be obtained. T o obtain greater accuracy or to ver- ify proper operation, the sensor must be calibrated as a loop with its comp atible analyzer or transmitter . 2.2.1 Flow ...

  • Emerson Process Management TF396 - page 8

    4 MODEL TF396 SECTION 2.0 INST ALLA TION FIGURE 2-1. Dimensional Drawing DWG . NO. REV . 4TF39604 B MILLIMETER INCH FIGURE 2-2. Flow-Through T ee with Adapter (PN 915240-xx*) MILLIMETER INCH xx* Process Connection Threads 03 3/4 inch 04 1 inch 05 1-1/2 inch SENSOR CABLE WITH CONNECTOR - NOT SHOWN ...

  • Emerson Process Management TF396 - page 9

    MODEL TF396 SECTION 2.0 INST ALLA TION DWG . NO. REV . 4TF39601 A 5 FIGURE 2-4. Model TF396 with Insertion Mounting Adapter PN 23242-02 FIGURE 2-3. Flow-Through and Insertion Inst allations DWG . NO. REV . 40396P05 C ...

  • Emerson Process Management TF396 - page 10

    MODEL TF396 SECTION 2.0 INST ALLA TION FIGURE 2-5. Submersion Inst allations WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH DWG . NO. REV . 4TF39602 A DWG . NO. REV . 4TF39603 B 6 PN 23550-00 (WITHOUT PREAMP) ...

  • Emerson Process Management TF396 - page 11

    7 MODEL TF396 SECTION 2.0 INST ALLA TION FIGURE 2-7. Jet Spray Cleaner PN 12707-00 MILLIMETER INCH LOW FLOW CELL PN 24091-00 Inlet and outlet connections are stainless steel and take 1/4-inch OD tubing. Flow cell is polycarbonate with 1/4-inch FNPT fittings. WETTED MA TERIALS: BODY - ACRYLIC NUT - CPVC FITTINGS - 316 SST SEALS - BUNA N FLOW CELL RA ...

  • Emerson Process Management TF396 - page 12

    8 Wiring. The Model TF396 has a mating cable with built-in preamplifier and is offered with a shielded cable. The cable should be handled carefully and kept dry and free of corrosive chemicals at all times. Extreme care should be used to prevent it from being twisted, damaged or scraped by rough, sharp edges or surfaces. Please refer to Figures 3-1 ...

  • Emerson Process Management TF396 - page 13

    9 MODEL TF396 SECTION 3.0 WIRING - MODEL TF396 FIGURE 3-1. Wiring to Model 1055. DWG . NO. REV . 14055103 B DWG . NO. REV . 41055102 B ...

  • Emerson Process Management TF396 - page 14

    10 MODEL TF396 SECTION 3.0 WIRING - MODEL TF396 FIGURE 3-2. Wiring to Model 54e. DWG . NO. REV . 40054E04 A FIGURE 3-2. Wiring to Models 3081, 4081, & 5081. DWG . NO. REV . 40508114 A ...

  • Emerson Process Management TF396 - page 15

    Recommended pH Sensor St andardization: For maximum accuracy , the sensor can be standardized online or with a process grab sample after a buf fer calibra- tion has been performed and the sensor has been condi- tioned to the process. S t andardization account s for the sensor junction potential and other interferences. S t andardization will not ch ...

  • Emerson Process Management TF396 - page 16

    12 MODEL TF396 SECTION 5.0 MAINTENANCE The Model TF396 Sensors require minimum mainte- nance. The sensor should be kept clean and free of debris and sediment at all times. The frequency of cleaning by wiping or brushing with a soft cloth or brush is determined by the nature of the solution being measured. The sensor should be removed from the proce ...

  • Emerson Process Management TF396 - page 17

    13 MODEL TF396 SECTION 6.0 RETURN OF MA TERIAL SECTION 6.0 RETURN OF MA TERIAL 6.1 GENERAL. T o expedite the repair and return of instruments, prop- er communication between the customer and the fac- tory is important. Before returning a product for repair , call 1-949-757-8500 for a Return Materials Authorization (RMA) number . 6.2 W ARRANTY REP A ...

  • Emerson Process Management TF396 - page 18

    FROM: RETURN BILL T O: _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ CUSTOMER/USER MUST SUBMIT MA TERIAL SAFETY SHEET (MSDS) O ...

  • Emerson Process Management TF396 - page 19

    W ARRANTY Seller warrants that the firmware will execute the programming instructions provided by Seller , and that the Goods manufactured or Services provided by Seller will be free from defects in materials or workmanship under normal use and care until the expira- tion of the applicable warranty period. Goods are warranted for twelve (12) months ...

  • Emerson Process Management TF396 - page 20

    Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .rosemountanalytical.com Specifications subject to change without notice. 8 Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA T el: (949) 757-8500 Fax: (949) 474-7250 http://www .ros ...

メーカー Emerson Process Management カテゴリー Stud Sensor

Emerson Process Management TF396のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TF396の取扱説明書
- Emerson Process Managementの製品カード
- パンフレット
- またはEmerson Process Management TF396の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson Process Management TF396の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson Process Management TF396の取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson Process Management TF396のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson Process Management TF396の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Emerson Process Management TF396デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson Process Management TF396を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson Process Management TF396ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emerson Process Managementの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson Process Management TF396の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson Process Management TF396の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson Process Management TF396に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson Process Management TF396デバイスの基本機能を使うにあたってのヒント。 Emerson Process Management TF396のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson Process Management TF396に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson Process Management TF396のメーカー/サービスへの連絡先に関する情報。

Emerson Process Management TF396についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson Process Management TF396の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson Process Management TF396で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)