Kodak P-255の取扱説明書

12ページ 0.16 mb
ダウンロード

ページに移動 of 12

Summary
  • Kodak P-255 - page 1

    ©Eastman Kodak Company, 2 000 June 2003 • P-255 TECHNICAL DATA / BLACK-AND-WHITE FILM K OD AK PR OFESSIONAL T echnical Pa n F i l m K OD AK PR OFESSION AL T echnical Pan Film is K odak’ s slo west and finest-grained black -and-white film for pictorial photography (when dev eloped in KOD AK TECHNIDOL Liquid Dev eloper). It is a v ariable-contra ...

  • Kodak P-255 - page 2

    2 KODAK PROFESSIONAL Technical Pan Film • P-255 SPECTRAL SENSITIVITY T echnical Pan Film has reas onably uniform spectral sensitivity at all visible wav elengths out to 690 nanometres (nm). Because of this extended red sensitivity , red areas and flesh tones may appear lighter than the y would with con ventional black-and-white films. This is oft ...

  • Kodak P-255 - page 3

    P-255 • P-255 3 Adjustments f or Long and Short Exposures Compensate for the reciprocity ch aracteristics of this f ilm by increasing exposure and adjusting the dev elopment as sho wn. If Indicated Exposure Time Is (seconds) Use This Lens- Aperture Adjustment OR This Adjusted Exposure Time (seconds) AND Use This Development Adjustment 1/10,000 No ...

  • Kodak P-255 - page 4

    4 KODAK PROFESSIONAL Technical Pan Film • P-255 SPECIFIC APPLICA TIONS Pictorial Photograph y These films produce high-quality pictorial negatives when processed in KOD AK TECHNIDO L Liquid Developer . (See “PR OCESSING. ”) Con ventional de v elopers generally produce contrast too high for normal pictorial pho tography . Process the f ilm acc ...

  • Kodak P-255 - page 5

    KODAK PROFESSIONAL Technical Pan Film • P-255 5 Photomicro graphy The lo w contrast of most micr oscopic subjects often requires a contrast-enhancing film-and-de v eloper combination and (with stained specimens) a contrast-enhancing filter . For routine photomi crography of H and E-st ained tissue, try a broad-band yellow-green f ilter (e.g., a K ...

  • Kodak P-255 - page 6

    6 KODAK PROFESSIONAL Technical Pan Film • P-255 PR OCESSING Handle unprocessed film in total darkness. After dev elopment is half complete, you can use a suitable a safelight lamp equipped with a KOD AK 3 Safelight Filter (dark green) and a 15-watt b ulb for a fe w seconds. K eep the safelight at least 4 feet (1 .2 metres) from the film. When you ...

  • Kodak P-255 - page 7

    KODAK PROFESSIONAL Technical Pan Film • P-255 7 Final Steps in T ank Processing— 68 to 86°F (20 to 30°C) Note: Keep the rinse and fix temperatures within 3°F (1.7°C) of the developer tem perature, and the wash temperature within 5°F (3°C) of the developer temperature. Rinse the film in K OD AK Indicator Stop Bath or K OD AK EKT AFLO Stop ...

  • Kodak P-255 - page 8

    8 KODAK PROFESSIONAL Technical Pan Film • P-255 Final Steps in T ray Pr ocessing— 65 to 70°F (18 to 21°C) Rinse the f ilm at 65 to 70°F (18 to 21°C) in K OD AK Indicator Stop Bath or K OD AK EKT AFLO Stop Bath for 15 to 30 seconds. Use running water for 30 seconds if no stop bath is av ailable. Put the first sheet int o the st op bath and a ...

  • Kodak P-255 - page 9

    KODAK PROFESSIONAL Technical Pan Film • P-255 9 K OD AK DURAFLO R T Dev eloper Replenisher K OD AK DURAFLO R T Dev eloper Starter K OD AK Rapid Fixer Processing Sequence PRINTING The 0.1 neutral densit y built into the EST AR- AH Base is one-half to one-third that found in conv entional 35 mm picture-taking films. Correctly exposed and processed ...

  • Kodak P-255 - page 10

    10 KODAK PROFESSIONAL Technical Pan Film • P-255 Characterist ic Curves 2.50 Contrast Index: 200 Exposure Index: agitation at 30-second intervals Tungsten, 1/25 second Small tank, KODAK DEKTOL Exposure: Process: Developer, 3 minutes at 68 F (20 C), LOG EXPOSURE (lux-seconds) 3.0 0.0 2.0 DENSITY 1.0 2.0 3.0 4.0 1.0 0.0 1.0 F002_0188AC =3.60 2 min ...

  • Kodak P-255 - page 11

    KODAK PROFESSIONAL Technical Pan Film • P-255 11 0.58 0.64 0.48 0.70 Index Contrast 25 20 16 25 Exposure Index 11 9 7 5 Time (min) Developing 5 min =0.50 11 min =0.70 7 min =0.60 9 min =0.65 Process: Exposure: Developer 5, 7, 9, and 11 minutes at Small tank, KODAK TECHNIDOL Liquid Daylight, 1/25 second 68 F (20 C), agitation at 30-second interval ...

  • Kodak P-255 - page 12

    Minor Revis i o n 6- 03 Printed in U.S.A. KODAK PROFESSIONAL T echnical Pan Film KODAK Publication No. P-255 CAT 817 2785 QUICK REFERENCE GUID E T O DEVELOPERS MORE INFORMA TION K odak has many publications to assist you with information on Kodak products, equipment, and materials. Additional information is availa ble on th e Kodak websi te and thr ...

メーカー Kodak カテゴリー Film Camera

Kodak P-255のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- P-255の取扱説明書
- Kodakの製品カード
- パンフレット
- またはKodak P-255の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Kodak P-255の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Kodak P-255の取り付け説明書、サービスマニュアル、簡易説明書、またはKodak P-255のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Kodak P-255の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Kodak P-255デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがKodak P-255を使用するのを助ける技術的文書のことです。説明書は通常、全てのKodak P-255ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Kodakの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Kodak P-255の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははKodak P-255の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Kodak P-255に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Kodak P-255デバイスの基本機能を使うにあたってのヒント。 Kodak P-255のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Kodak P-255に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるKodak P-255のメーカー/サービスへの連絡先に関する情報。

Kodak P-255についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもKodak P-255の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがKodak P-255で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)