  • Health O Meter 7630 - page 1

    IMPORT ANT NOTES Y our Measure for Good Health™ UPPER ARM Blood Pressure Monitor ...

  • Health O Meter 7630 - page 2

    2 2 IMPORT ANT SAFETY INSTRUCTIONS Upper Arm Blood Pressure Monitor DO NOT DESTROY Features: • Semi-Automatic • Large, Easy-T o-Read Digital Display • 60 Automatic Memory Feature • Convenient Storage Case In accordance with International Standards: INSTRUCCIONES DE MEDIDAS IMPORT ANTES Medidor de Presión Arterial NO DESTRUY A Característi ...

  • Health O Meter 7630 - page 3

    3 T able of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Product Component Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Standards of Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 About ...

  • Health O Meter 7630 - page 4

    4 6 4 Blood pressure measurements determined with the Health o meter ® blood pressure monitor are equivalent to those using the cuff/stethoscope auscultation method and are within the limits prescribed by the American National Standards Institute (ANSI). This monitor is to be used by an adult and is intended for in-home use. Note: Please read this ...

  • Health O Meter 7630 - page 5

    5 Standards of Quality This Blood Pressure Monitor conforms with the American National Standards Institute/American Association of Medical Instrumentation Standards for Non-Invasive Blood Pressure Monitors. In addition, the device complies with the European regulations and bears the CE mark “CE 0366”. The quality of the device has been verified ...

  • Health O Meter 7630 - page 6

    6 6 Blood Pressure Standard The W orld Health Organization (WHO) has developed a blood pressure standard, according to which areas of low and high-risk blood pressure are identified. This standard, however , is a general guideline as individual blood pressure varies among different people and different age groups, etc. It is important that you cons ...

  • Health O Meter 7630 - page 7

    7 7 Display Explanations Display: Systolic Pressure Diastolic Pressure Pulse Rate No. of Memory Sequence Icons: Appears when manual cuff inflation is needed Appears when manual cuff deflation is needed Appears when batteries should be replaced Shows the Pulse Rate per minute Occurs when a mistake wasmade during measurement Installing Batteries 1. P ...

  • Health O Meter 7630 - page 8

    14 8 8 Y ou need to replace the batteries when: 1. The “low battery” icon appears on the display . 2. The “ POWER ” button is pushed and nothing appears on the display . Note: Discard used Alkaline batteries as directed by your local environmental codes. HOW TO USE: Helpful T ips Here are a few tips to help you obtain more accurate readings ...

  • Health O Meter 7630 - page 9

    9 9 Applying the Arm Cuff 1. Plug the cuff connector tube (A) into the unit. 2. Unwrap the arm cuff, leaving the “Index” end of the cuff through the metal D-ring (B) of the cuff. 3. Put your left arm through the cuff loop. The “OK” range indication should be positioned at the top with the rubber tube pointing downward in the direction of yo ...

  • Health O Meter 7630 - page 10

    10 10 5. If the Index line falls within the “OK” range, indicated at the edge of the cuff, this cuff is suitable for your use. If the Index line falls outside of the “OK” range, you may need a larger cuff for accurate measurement. Please consult your local retailer for the purchase of a larger cuff or visit the Health o meter ® website at ...

  • Health O Meter 7630 - page 11

    2. Squeeze the bulb to increase pressure in the arm cuff. The display will show the pressure reading within the cuff. Continue pumping until the pressure reaches approximately 50~60 mmHg above your normal systolic pressure. If the pressure in the cuff is not high enough, an upward arrow ( ) will display to remind you that you should continue pumpin ...

  • Health O Meter 7630 - page 12

    22 12 12 Recalling Memory 1. T o recall stored blood pressure readings from the memory, simply press the MEMORY button. The last set of readings recorded in memory will be displayed. 2. Another press of the MEMORY button will recall the previous set of readings. 3. All readings stored in memory will be displayed with their corresponding sequence nu ...

  • Health O Meter 7630 - page 13

    Síntoma Ninguna exhibición de pantalla cuando se presiona POWER La pantalla muestra la señal EE o el valor de presión arterial mostrado es demasiado bajo (o alto) Punto a V erificar ¿Están agotadas las baterías? ¿Han sido colocadas las baterías en la posición correcta dentro del compartimiento? ¿Está correctamente tensado el brazalete? ...

  • Health O Meter 7630 - page 14

    14 14 Precautionary Notes: 1. Y our Health o meter ® monitor contains high-precision components. Therefore, avoid extreme temperatures, humidity , and direct sunlight. Avoid dropping or sharp impacts to the main unit, and protect it from dust. 2. Clean the blood pressure monitor body and the cuff carefully with a slightly dampened soft cloth. Do n ...

  • Health O Meter 7630 - page 15

    15 15 Especificaciones: Método de Medición : Oscilométrico Rango de Medición : Presión 20 ~ 280mmHg; Pulso: 40 – 180 latidos/minuto Sensor de Presión : Semi conductor Precisión : Presión ± 3mmHg; Pulso: ± 5% de lectura Inflación : Inflado Manual Desinflado : Válvula de Desfogue de Presión Automática Capacidad de Memoria : Memoria de ...

  • Health O Meter 7630 - page 16

    16 16 Warranty Information Y our Health o meter ® Blood Pressure Monitor is covered under the limited Warranty offered by Sunbeam Products, Inc. (“Sunbeam”). Sunbeam warrants that for a period of five years from the date of purchase, this product will be free from defects in material and workmanship. Sunbeam, at its option, will repair or repl ...

  • Health O Meter 7630 - page 17

    IMPORT ANT NOTES Y our Measure for Good Health™ UPPER ARM Blood Pressure Monitor Please read this entire manual carefully before using this device. Model 7630 NOT AS IMPORT ANTES Y our Measure for Good Health™ DE BRAZO Medidor de Presión Arterial ...

  • Health O Meter 7630 - page 18

    2 2 IMPORT ANT SAFETY INSTRUCTIONS Upper Arm Blood Pressure Monitor DO NOT DESTROY Features: • Semi-Automatic • Large, Easy-T o-Read Digital Display • 60 Automatic Memory Feature • Convenient Storage Case In accordance with International Standards: INSTRUCCIONES DE MEDIDAS IMPORT ANTES Medidor de Presión Arterial NO DESTRUY A Característi ...

  • Health O Meter 7630 - page 19

    3 T able of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Product Component Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Standards of Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 About ...

  • Health O Meter 7630 - page 20

    4 6 4 Blood pressure measurements determined with the Health o meter ® blood pressure monitor are equivalent to those using the cuff/stethoscope auscultation method and are within the limits prescribed by the American National Standards Institute (ANSI). This monitor is to be used by an adult and is intended for in-home use. Note: Please read this ...

  • Health O Meter 7630 - page 21

    5 Standards of Quality This Blood Pressure Monitor conforms with the American National Standards Institute/American Association of Medical Instrumentation Standards for Non-Invasive Blood Pressure Monitors. In addition, the device complies with the European regulations and bears the CE mark “CE 0366”. The quality of the device has been verified ...

  • Health O Meter 7630 - page 22

    6 6 Blood Pressure Standard The W orld Health Organization (WHO) has developed a blood pressure standard, according to which areas of low and high-risk blood pressure are identified. This standard, however , is a general guideline as individual blood pressure varies among different people and different age groups, etc. It is important that you cons ...

  • Health O Meter 7630 - page 23

    7 7 Display Explanations Display: Systolic Pressure Diastolic Pressure Pulse Rate No. of Memory Sequence Icons: Appears when manual cuff inflation is needed Appears when manual cuff deflation is needed Appears when batteries should be replaced Shows the Pulse Rate per minute Occurs when a mistake wasmade during measurement Installing Batteries 1. P ...

  • Health O Meter 7630 - page 24

    14 8 8 Y ou need to replace the batteries when: 1. The “low battery” icon appears on the display . 2. The “ POWER ” button is pushed and nothing appears on the display . Note: Discard used Alkaline batteries as directed by your local environmental codes. HOW TO USE: Helpful T ips Here are a few tips to help you obtain more accurate readings ...

  • Health O Meter 7630 - page 25

    9 9 Applying the Arm Cuff 1. Plug the cuff connector tube (A) into the unit. 2. Unwrap the arm cuff, leaving the “Index” end of the cuff through the metal D-ring (B) of the cuff. 3. Put your left arm through the cuff loop. The “OK” range indication should be positioned at the top with the rubber tube pointing downward in the direction of yo ...

  • Health O Meter 7630 - page 26

    10 10 5. If the Index line falls within the “OK” range, indicated at the edge of the cuff, this cuff is suitable for your use. If the Index line falls outside of the “OK” range, you may need a larger cuff for accurate measurement. Please consult your local retailer for the purchase of a larger cuff or visit the Health o meter ® website at ...

  • Health O Meter 7630 - page 27

    2. Squeeze the bulb to increase pressure in the arm cuff. The display will show the pressure reading within the cuff. Continue pumping until the pressure reaches approximately 50~60 mmHg above your normal systolic pressure. If the pressure in the cuff is not high enough, an upward arrow ( ) will display to remind you that you should continue pumpin ...

  • Health O Meter 7630 - page 28

    22 12 12 Recalling Memory 1. T o recall stored blood pressure readings from the memory, simply press the MEMORY button. The last set of readings recorded in memory will be displayed. 2. Another press of the MEMORY button will recall the previous set of readings. 3. All readings stored in memory will be displayed with their corresponding sequence nu ...

  • Health O Meter 7630 - page 29

    Síntoma Ninguna exhibición de pantalla cuando se presiona POWER La pantalla muestra la señal EE o el valor de presión arterial mostrado es demasiado bajo (o alto) Punto a V erificar ¿Están agotadas las baterías? ¿Han sido colocadas las baterías en la posición correcta dentro del compartimiento? ¿Está correctamente tensado el brazalete? ...

  • Health O Meter 7630 - page 30

    14 14 Precautionary Notes: 1. Y our Health o meter ® monitor contains high-precision components. Therefore, avoid extreme temperatures, humidity , and direct sunlight. Avoid dropping or sharp impacts to the main unit, and protect it from dust. 2. Clean the blood pressure monitor body and the cuff carefully with a slightly dampened soft cloth. Do n ...

  • Health O Meter 7630 - page 31

    15 15 Especificaciones: Método de Medición : Oscilométrico Rango de Medición : Presión 20 ~ 280mmHg; Pulso: 40 – 180 latidos/minuto Sensor de Presión : Semi conductor Precisión : Presión ± 3mmHg; Pulso: ± 5% de lectura Inflación : Inflado Manual Desinflado : Válvula de Desfogue de Presión Automática Capacidad de Memoria : Memoria de ...

  • Health O Meter 7630 - page 32

    16 16 Warranty Information Y our Health o meter ® Blood Pressure Monitor is covered under the limited Warranty offered by Sunbeam Products, Inc. (“Sunbeam”). Sunbeam warrants that for a period of five years from the date of purchase, this product will be free from defects in material and workmanship. Sunbeam, at its option, will repair or repl ...

メーカー Health O Meter カテゴリー Blood Pressure Monitor

Health O Meter 7630のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 7630の取扱説明書
- Health O Meterの製品カード
- パンフレット
- またはHealth O Meter 7630の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Health O Meter 7630の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Health O Meter 7630の取り付け説明書、サービスマニュアル、簡易説明書、またはHealth O Meter 7630のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Health O Meter 7630の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Health O Meter 7630デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHealth O Meter 7630を使用するのを助ける技術的文書のことです。説明書は通常、全てのHealth O Meter 7630ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Health O Meterの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Health O Meter 7630の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHealth O Meter 7630の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Health O Meter 7630に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Health O Meter 7630デバイスの基本機能を使うにあたってのヒント。 Health O Meter 7630のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Health O Meter 7630に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHealth O Meter 7630のメーカー/サービスへの連絡先に関する情報。

Health O Meter 7630についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHealth O Meter 7630の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHealth O Meter 7630で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)