Honda Power Equipment WSP33AAの取扱説明書

23ページ 1.78 mb
ダウンロード

ページに移動 of 23

Summary
  • Honda Power Equipment WSP33AA - page 1

    OPERATOR'S MANUAL ©2003 American Honda Motor Co., Inc. — All Rights Reserved SUBMERSIBLE PUMP WSP33AA • WSP53AA • WSP73AA © 2004 American Honda Motor Co., Inc. – All Rights Reserved BY : ...

  • Honda Power Equipment WSP33AA - page 2

    Thank you f or purchasing this Honda Stainless Steel Sump Pump . W e hope you are pleased with y our purchase and that our pumps will provide y ou with long ser vice lif e and e xceptional perf or mance. T o ensure satisf actor y ser vice lif e, there are se v eral consid- erations regarding proper installation, operation and po wer source. Please ...

  • Honda Power Equipment WSP33AA - page 3

    1 Impor tant Safeguar ds T o reduce risk of injur y , alwa ys f ollow these instructions and saf ety precautions when using this pump and to maintain warr anty . Read All Instructions Prior to Installation (SA VE THESE INSTR UCTIONS) Installation/Operation: • Ne v er lift or carr y pump by the electrical cord. Use a chain or rope affixed on handl ...

  • Honda Power Equipment WSP33AA - page 4

    2 Impor tant Safeguar ds Pr oper Lifting: A separate chain or r ope should be attached to the handle f or normal lifting. Please note that this will help prevent dama ge due to inadver tent lifting of the pump b y the power cor d. Rope attached to automatic pump f or lifting and installation. Rope attached to manual pump f or lifting and installati ...

  • Honda Power Equipment WSP33AA - page 5

    3 Section P age General Application Inf ormation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Saf ety Inf or mation and Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mate r ials Needed and ...

  • Honda Power Equipment WSP33AA - page 6

    4 saf ety reasons. Y ou should nev er touch a sump pump or discharge piping while the pump is connected to electrical power and w ater is present. The pump should be disconnected from the electrical source before handling in all cases . Dischar ge Piping Installation T o assure the maximum perf or mance from your sump pump , the discharge pipe size ...

  • Honda Power Equipment WSP33AA - page 7

    Basin and Cover The basin should not be less than 18 inches in diameter and 24 inches deep . Larger diameters are advisable in instances of increased pump capacity requirements: The basin should be located such that all water flo ws into the basin due to gra vity . Outdoor installations should be at a sufficient depth to ensure protection from free ...

  • Honda Power Equipment WSP33AA - page 8

    6 Chec k the nameplate for y our pump’ s head (HEAD), discharge v olume (CAP A CITY), speed (SPEED), motor v oltage and current. Other specifications are noted in the char t below: Dischar ge Motor Motor W eight Model Diameter (Inch) Output (HP) Phase V oltage (LB) WSP33AA 1 1 / 4 1 / 3 1 115 11 WSP53AA 1 1 / 2 1 / 2 1 115 27 WSP73AA 1 1 / 2 3 / ...

  • Honda Power Equipment WSP33AA - page 9

    7 Step 1 Inspection: Y our pump has been carefully pac kaged to pre vent damage during shipping. Howe ver , occasional damage does occur due to rough handling. Carefully inspect the pump f or damage that could cause it to f ail. Step 2: Attach desired length of PVC or ABS discharge pipe to pump outlet, using PVC adapter (1 1 / 4 " pipe and ada ...

  • Honda Power Equipment WSP33AA - page 10

    8 IMPOR T ANT INSTRUCTIONS BEFORE INST ALLA TION Failure to f ollow these instructions ma y cause serious bodily injury and/or pr oper ty damage. • Pumps are 115 V , 60 Hz and are g rounded to pre vent electrical shock. W ARNING: Risk of electr ic shock—this pump is supplied with a g rounding conductor and grounding-type attachment plug. T o re ...

  • Honda Power Equipment WSP33AA - page 11

    9 Ref er to the installation illustration on the f ollowing page f or the f ollowing instructions. Be cer tain sump basin is clean and all power to pump is shut off . If pump f ails to ope r ate prope r ly after installation, re f er to the trou b leshooting che c klist on page 1 4 or contact Honda ser vicing dealer . General Materials Needed • O ...

  • Honda Power Equipment WSP33AA - page 12

    Submersib le Pump Installation (cont.) Step 5 – Plug in and fill sump basin with water . Pump should tur n on at 13'' to 14'' water le vel. If it does not turn on at 13'' to 14'' water le v el, remov e the float cord from the clip and reattach in a higher or low er position, so that the pump tur ns on at th ...

  • Honda Power Equipment WSP33AA - page 13

    11 10 1 / 2 " Min. 14" Min. Bottom of inlet pipe Sump pump Drill 1/8" relief hole 5" abov e pump discharge Discharge piping can be PVC or ABS plastic with proper adapters, or can be galv . steel shut-off gate v alve (optional) T ur n on le vel Grounded type 115 v olt receptacle min. height abo ve floor – 4 ft. 13 3 / 8 " ...

  • Honda Power Equipment WSP33AA - page 14

    12 A utomatic Operation T ype Output (Single Phase) Motor Wiring Diagram Operation Chec k the water le v el bef ore star ting the pump . If the pump is operated contin uously for an e xtended per iod of time in a dr y condition or at the low est water le vel, the motor protector will be activ ated in single phase units. Constant repetition of this ...

  • Honda Power Equipment WSP33AA - page 15

    13 Model WSP33AA WSP53AA WSP73AA P erformance: ISO 2548 Standard Optional Discharge Size 1 / 3 HP – 1 1 / 4 inch 1 / 2 HP and 3 / 4 HP – 1 1 / 2 inch Range of P erformance Capacity: up to 74 GPM Head: up to 54 feet Limitation Maximum W ater T emperature 122°F/50°C Solids 3 / 8 '' Spherical (2% by concentration) Speed 3600 RPM Materi ...

  • Honda Power Equipment WSP33AA - page 16

    14 POSSIBLE CA USES • Line circuit breaker is off , or fuse is blown or loose . • W ater le vel in sump has not reached turn-on lev el as indicated in installation dra wing. • Pump cord is not making contact in receptacle. • Float is stuck. It should oper ate freely in basin. • If all of the abov e are OK, then the motor winding ma y be o ...

  • Honda Power Equipment WSP33AA - page 17

    15 W ARNING: Pump w arranty becomes v oid if you remo v e motor housing, unscre w impeller , or otherwise remov e impeller seal. If pump does not operate properly , follo w the steps shown under T roub leshooting. For an y work on pump or s witch, alwa ys unplug power cor d(s). Do not just turn off cir cuit breaker or unscrew fuse. Cleaning float I ...

  • Honda Power Equipment WSP33AA - page 18

    16 Sectional View – WSP33AA * Recommended spare parts P ar t ASTM, AISI No. f or Ref. No. Name Material Code 1 Unit 007 Outer Casing 304 Stainless AISI 304 1 012 Suction Cov er Nor yl G.F . 3 1 021 Impeller Nor yl G.F . 3 1 041 Slee ve 304 Stainless/Ceramic 1 048 Impeller Nut 304 Stainless AISI 304 1 * 114 Oil Seal NBR 1 set 200 Lifting Hanger 30 ...

  • Honda Power Equipment WSP33AA - page 19

    17 Sectional View – WSP53AA, WSP73AA * Recommended spare parts P ar t ASTM, AISI No. f or Ref. No. Name Material Code 1 Unit 007 Outer casing 304 Stainless AISI 304 1 009 Inner casing 304 Stainless AISI 304 1 016 Seal cov er 304 Stainless AISI 304 1 021 Impeller 304 Stainless AISI 304 1 039 K ey 304 Stainless AISI 304 1 048 Impeller nut 304 Stain ...

  • Honda Power Equipment WSP33AA - page 20

    Disassembl y and Assembl y Disassembl y When disassemb ling pump , hav e a piece of cardboard or wooden board ready to place the diff erent par ts on as you work. Do not pile par ts on top of each other . The y should be laid out neatly in rows . The O-ring and gasket can not be used again once the y are remov ed. Hav e replacement par ts ready . D ...

  • Honda Power Equipment WSP33AA - page 21

    19 Customer Service Information Ser vicing dealership personnel are trained prof essionals . The y should be able to ans wer an y question you ma y hav e. If y ou encounter a problem that y our dealer does not solv e to your satisf action, please discuss it with the dealership's management. The Service Manager , General Manager , or Owner can ...

  • Honda Power Equipment WSP33AA - page 22

    0204 HONDA WSP manual.qxd 3/24/2004 2:14 PM Page 24 ...

  • Honda Power Equipment WSP33AA - page 23

    Printed on Recycled Paper PRINTED IN U.S.A. POM53680 IPC 2200.200 5 .04 P/N 31WSP60 2 ...

メーカー Honda Power Equipment カテゴリー Water Pump

Honda Power Equipment WSP33AAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- WSP33AAの取扱説明書
- Honda Power Equipmentの製品カード
- パンフレット
- またはHonda Power Equipment WSP33AAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Honda Power Equipment WSP33AAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Honda Power Equipment WSP33AAの取り付け説明書、サービスマニュアル、簡易説明書、またはHonda Power Equipment WSP33AAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Honda Power Equipment WSP33AAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Honda Power Equipment WSP33AAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHonda Power Equipment WSP33AAを使用するのを助ける技術的文書のことです。説明書は通常、全てのHonda Power Equipment WSP33AAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Honda Power Equipmentの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Honda Power Equipment WSP33AAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHonda Power Equipment WSP33AAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Honda Power Equipment WSP33AAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Honda Power Equipment WSP33AAデバイスの基本機能を使うにあたってのヒント。 Honda Power Equipment WSP33AAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Honda Power Equipment WSP33AAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHonda Power Equipment WSP33AAのメーカー/サービスへの連絡先に関する情報。

Honda Power Equipment WSP33AAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHonda Power Equipment WSP33AAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHonda Power Equipment WSP33AAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)