SPX Cooling Technologies 1200の取扱説明書

12ページ 1.21 mb
ダウンロード

ページに移動 of 12

Summary
  • SPX Cooling Technologies 1200 - page 1

    / Mar le y Sigma 1 0 0 0/120 0 Cooling T ower / ...

  • SPX Cooling Technologies 1200 - page 2

    2 Y ou’ll enjoy single source r esponsibility and reliability because we design and manufacture virtually all major cooling tower components. All Marley components are designed and selected to be part of an integrated system. For example, the spray pattern from nozzles and the pr essure dr op through drift eliminators both affect a fill’ s hea ...

  • SPX Cooling Technologies 1200 - page 3

    3 / Sigma Adv antag e / •  GuaranteedPerformance. Don’t r ely on outside agencies with limited enforcement powers. W e’ll stand by our responsibility for r eliable thermal performance. We designed it. W e rate it. We guarantee it! •  Exclusive5-Y earMechanicalW arranty . Y our no- cost assurance of trouble-fr ee mech ...

  • SPX Cooling Technologies 1200 - page 4

    4 / Constr uction and Components / Fill/Louvers/Drift Eliminators Marley high-performance film fill is the heart of every Sigma tower . A repeating chevr on pattern provides the wetted surface and air turbulence necessary for proper heat transfer , while minimizing resistance to airflow so you’ll save on fan power . Molded protrusions on each ...

  • SPX Cooling Technologies 1200 - page 5

    5 fans, used on larger models, include hollow GRE (glass- reinfor ced epoxy) blades and epoxy-coated cast iron hubs. Blades on both fan types are adjustable in pitch, so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual job site restrictions. The true airfoil blades, designed specifically for cooling tow ...

  • SPX Cooling Technologies 1200 - page 6

    6 W ater Distribution System The gravity-flow water distribution system designed into the Sigma tower essentially reduces pump head to its most basic component – static lift – saving you money on pump power . Y ou won’t have to for ce water through internal piping and pressur e spray nozzles, as you would in a counterflow tower . W arm wate ...

  • SPX Cooling Technologies 1200 - page 7

    7 The 4" x" 4 tower diagonals carry loads to heavy- duty hot-dip galvanized steel anchor plates or hot-dip galvanized anchor weldments. The system of longitudinal and transverse diagonal bracing provides stability in a true tension-compression design. the mechanical equipment. The taller fan cylinders used on Series 1200 models effectivel ...

  • SPX Cooling Technologies 1200 - page 8

    8 / A v ailable Options / Accessory Description and Remarks Accessory Description and Remarks Plywood Cold W ater Collection Basin Pressur e-treated Douglas fir plywood collection basin for towers located above grade. See page 11. Bottom-Outlet Sump Square-plan galvanized steel sump with bottom outlet. Outlet connection is a hole and bolt circle c ...

  • SPX Cooling Technologies 1200 - page 9

    9 Cell Partition Options Every Sigma tower includes plenum chamber partitions and hot water distribution basin partitions between adjacent cells. Plenum partitions ensure consistent thermal performance as you shut off one fan at a time. They keep air from entering an operating cell thr ough an adjacent idle fan, maintaining efficient thermal perfo ...

  • SPX Cooling Technologies 1200 - page 10

    10 Fire Pr otection Options The PVC fill, louvers and drift eliminators used on Sigma towers are fir e-retar dant, having flame spread ratings less than 25 per ASTM E-84. Standard fan decking material is pressur e-treated fir plywood which ignites poorly and burns slowly . For these reasons, governing agencies (such as Factory Mutual) may not r ...

  • SPX Cooling Technologies 1200 - page 11

    11 Cold W ater Collection Basins If you plan to locate your tower above grade, a treated Douglas fir Marley cold water collection basin is available, complete with the necessary operating accessories. The basin floor is exterior grade, pressur e-treated fir plywood, supported on joists. Basin sides are plywood, machined to fit the basin floor ...

  • SPX Cooling Technologies 1200 - page 12

    / Additional Services / SPX Cooling T echnologies is dedicated to satisfying the needs of our customers—needs which begin far in advance of the actual purchase of a new Marley cooling tower , and vary over the operating lifetime of the project. Here is a partial listing of the additional services offer ed by SPX Cooling T echnologies to help you ...

メーカー SPX Cooling Technologies カテゴリー Ventilation Hood

SPX Cooling Technologies 1200のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1200の取扱説明書
- SPX Cooling Technologiesの製品カード
- パンフレット
- またはSPX Cooling Technologies 1200の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、SPX Cooling Technologies 1200の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、SPX Cooling Technologies 1200の取り付け説明書、サービスマニュアル、簡易説明書、またはSPX Cooling Technologies 1200のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、SPX Cooling Technologies 1200の製品を使用するにあたって最も人気のある説明書を閲覧できます。

SPX Cooling Technologies 1200デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSPX Cooling Technologies 1200を使用するのを助ける技術的文書のことです。説明書は通常、全てのSPX Cooling Technologies 1200ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

SPX Cooling Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. SPX Cooling Technologies 1200の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSPX Cooling Technologies 1200の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。SPX Cooling Technologies 1200に関してこのドキュメントで見つけることができる全てのヒントの目次
3. SPX Cooling Technologies 1200デバイスの基本機能を使うにあたってのヒント。 SPX Cooling Technologies 1200のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。SPX Cooling Technologies 1200に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSPX Cooling Technologies 1200のメーカー/サービスへの連絡先に関する情報。