    PLATINUM BEAM 5R KEEP THIS MANUAL FOR FUTURE NEEDS ...

  • Elation Professional XM485-V1.0-NR - page 2

    2 XM485-V1.0-NR ...

  • Elation Professional XM485-V1.0-NR - page 3

    ...

  • Elation Professional XM485-V1.0-NR - page 4

    2 Thank you for your patronage. W e are confident that our excellent products and service can satisfy you. For your own safety , please read this user manual carefully before installing the device. In order to install , operate, and maintain the lighting safety and correctly . W e suggest that the installation and operation s hould be done by the v ...

  • Elation Professional XM485-V1.0-NR - page 5

    3 · Stepless frost, 0%~100% linear change frost · Strobe/shutter: High speed shutter , 0-13 Hz or random strobe · Control board with full color LCD graphic display and touch-keyboard · Auto-program: 7 pre-built programs can be selected. · Software-upload by optional accessory via DMX line Overview SAFETY INSTRUCTIONS XM485-V1.0-NR 1) Lens 2) D ...

  • Elation Professional XM485-V1.0-NR - page 6

    4 This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. Important: Damages caused by the disregard of this user manual are not subject to warranty. The dealer w ...

  • Elation Professional XM485-V1.0-NR - page 7

    5 GENERAL GUIDELINES This device is a lighting effect for professional use on stages, in discotheques, theatres, etc., the device was designed for indoor use only . This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in the last page of this manual. Lighting effects are not desig ...

  • Elation Professional XM485-V1.0-NR - page 8

    6 Before replacing the lamp let the lamp cool down, because during operation, the lamp can reach very high temperature. During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a cloth to handle the lamps during insertion and removal. Do not install lamps with a higher wattage. They generate higher temperatures ...

  • Elation Professional XM485-V1.0-NR - page 9

    7 weight for 1 hour without any harming deformation. The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety rope. Never stand directly below the device when mounting, removing or servicing the fixture. The operator has to make sure the safety relating and machine technical installations are approved b ...

  • Elation Professional XM485-V1.0-NR - page 10

    8 Installation via the Omega holders a) Fixed the clamp on the bracket by tighten up the M12 screw on the bracket to the Ф 13 hole in the middle of the bracket. b) Insert the quick-lock fasteners of the first Omega holder into the respective holes on the bottom of the device. T ighten the quick-lock fasteners fully clockwise. c) Install the second ...

  • Elation Professional XM485-V1.0-NR - page 11

    9 DMX-512 connection with DMX terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator . This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simpl y an XLR plug w ...

  • Elation Professional XM485-V1.0-NR - page 12

    10 to 1, the second unit to 14(13 + 1), the third to 27 (13 + 14), and so on. Control Board The Control Board offers several features: you can s imply set the starting address , run the pre-programmed program or make a reset. The main menu is accessed by pressing the -button until the display starts flashing. Browse through the menu by pressing the ...

  • Elation Professional XM485-V1.0-NR - page 13

    11 T emperature Info Head T emperature Head T emperature Head T emperature Head T emperature Head T emperature XXX ℃ / ℉ XXX ℃ / ℉ T emperature in the head Software V ersion V er1.0…… V er1.0…… V er1.0…… V er1.0…… V er1.0…… V er1.0…… V er1.0…… Software version of each IC La mp Con trol Lamp On or Off Automatic La ...

  • Elation Professional XM485-V1.0-NR - page 14

    12 rs Mo de Set Edit User Mode Edit User Mode Max Channel = XX P AN = CH01 : Max Channel = XX P AN = CH01 : Max Channel = XX P AN = CH01 : Max Channel = XX P AN = CH01 : Max Channel = XX P AN = CH01 : Max Channel = XX P AN = CH01 : Preset User modes Edit Pro gra m Select Programs Select Programs Auto Pro Part 1 = Program 1 ~ 10 Program 1 Auto Pro P ...

  • Elation Professional XM485-V1.0-NR - page 15

    13 mode. Each slave setting will have a dif ferent function for a dynamic lightshow without a controller . Auto Program This function allows the internal programs to run in either stand-alone or master/ salve mode. In “Master” mode the fixture will send DMX data to other fixtures connect via the DMX chain. In “Alone” mode the fixture will o ...

  • Elation Professional XM485-V1.0-NR - page 16

    14 counter should be reset after every lamp change. Lamp Off Time This function displays the running time of the lamp from the last power on. The display shows “XXXX”, where “XXXX” represents the number of hours the lamp has been running since it was last struck. This counter is automatically reset after every power-on. Timer Password Use t ...

  • Elation Professional XM485-V1.0-NR - page 17

    15 Lamp Control: Lamp On or Off This function allows manual control of the lamp power via the on-board system menu. • Select “ON” if you wish to strike the lamp or “OFF” to switch it off. • Press “ENTER” to confirm. • Press the Mode/Esc-button to return to the main menu. Automatic La-On When in the “ON” position, this function ...

  • Elation Professional XM485-V1.0-NR - page 18

    16 Personality: Status setting Address via DMX - This function allows the DMX address to remotely be adjusted from a DMX console. This setting requires special settings for both the controller and the fixture. RDMX is on by default. For operational instructions please see Section 10/Page 35 of this manual “Remote DMX addressing.” No DMX Status ...

  • Elation Professional XM485-V1.0-NR - page 19

    17 includes original Design Spot 250s. There are 3 different mode variations; Speed 1 (Default): S lower than the original Design Spot 250 for smoother , more precise movements. Speed 2: Pan and T ilt speeds are identical to the first generation Design Spot 250. Speed 3: includes a faster Pan speed. Pan speed is 0.5 seconds faster than original DS- ...

  • Elation Professional XM485-V1.0-NR - page 20

    18 function is disabled as default. Key Lock – This function allows you to lock the keys on the display to prevent menu tampering. With this function you can activate the automatic keylock function. If this function is activated, the keys will be automatically locked in 15 seconds from the last command. In ord er to deactivate or temporarily deac ...

  • Elation Professional XM485-V1.0-NR - page 21

    19 Effect Adjust: T est Channel – This menu function allows the us er to select each individual fixture channel and test it’s function independently from the control board. Lamp adjustment (manual control) – This function readies the fixture for lamp optimization in a simple single step procedure. This function will center the pan and tilt mo ...

  • Elation Professional XM485-V1.0-NR - page 22

    20 external DMX controller . For detailed instructions on how to complete this task please see Section 12/ Page 39. Select program – This function allows the user to select one of ten of the user defined built-in programs. This program is then accessed in “Function Mode” under “Program Run.” Edit program – This function allows the user ...

  • Elation Professional XM485-V1.0-NR - page 23

    21 INSTRUCTIONS ON USE: DMX channel´s functions and their values (16 DMX channels): DMX channel´s functions and their values (16 DMX channels): DMX channel´s functions and their values (16 DMX channels): DMX channel´s functions and their values (16 DMX channels): DMX channel´s functions and their values (16 DMX channels): Mode/Channel Mode/Cha ...

  • Elation Professional XM485-V1.0-NR - page 24

    22 120-134 Rot. gobo 3 shake 135-149 Rot. gobo 4 shake 150-164 Rot. gobo 5 shake 165-179 Rot. gobo 6 shake 180-194 Rot. gobo 7 shake 195-209 Rot. gobo 8 shake 210-255 Rot. gobo wheel cont. rotation slow to fast 7 5 8   Rotating gobo index, rotating gobo r otation : 7 5 8 0-127 Gobo indexing 7 5 8 128-189 Forwards gobo rotation from fast to slow 7 ...

  • Elation Professional XM485-V1.0-NR - page 25

    23 10 8 12   Dimmer intensity: 10 8 12 0-255 Intensity 0 to 100%     13   Fine Dimmer intensity:     13 0-255 Dimmer intensity fine 11 9 14 Frost: 11 9 14 0-127 Disable frost 11 9 14 128-255 Enable frost 12 10 15   Speed Pan/Tilt movement: 12 10 15 0-225 max to min speed 12 10 15 226-235 blackout by movement 12 10 15 236-245 blackout ...

  • Elation Professional XM485-V1.0-NR - page 26

    24 some error in channel 1. If there are some errors on channel 1, channel 5, channel 6 at the same time, you may see the error message “Err channel is Color wheel”, “Err channel is Pan movement”, “Err channel is Tilt movement” flash repeated for 2 times, and then the fixture will generate a second reset. If the fixture remain error mes ...

  • Elation Professional XM485-V1.0-NR - page 27

    25 W e recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or solvents. There are no serviceable parts inside the device except for the lamp. Please refer to the instructions under “Installation instructions”. Should you need any spare parts, please order genuine parts from your local dealer . TE ...

メーカー Elation Professional カテゴリー All in One Printer

Elation Professional XM485-V1.0-NRのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- XM485-V1.0-NRの取扱説明書
- Elation Professionalの製品カード
- パンフレット
- またはElation Professional XM485-V1.0-NRの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Elation Professional XM485-V1.0-NRの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Elation Professional XM485-V1.0-NRの取り付け説明書、サービスマニュアル、簡易説明書、またはElation Professional XM485-V1.0-NRのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Elation Professional XM485-V1.0-NRの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Elation Professional XM485-V1.0-NRデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがElation Professional XM485-V1.0-NRを使用するのを助ける技術的文書のことです。説明書は通常、全てのElation Professional XM485-V1.0-NRユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Elation Professionalの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Elation Professional XM485-V1.0-NRの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははElation Professional XM485-V1.0-NRの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Elation Professional XM485-V1.0-NRに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Elation Professional XM485-V1.0-NRデバイスの基本機能を使うにあたってのヒント。 Elation Professional XM485-V1.0-NRのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Elation Professional XM485-V1.0-NRに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるElation Professional XM485-V1.0-NRのメーカー/サービスへの連絡先に関する情報。

Elation Professional XM485-V1.0-NRについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもElation Professional XM485-V1.0-NRの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがElation Professional XM485-V1.0-NRで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)