  • Bryant 350MAV - page 1

    WARNING: ELECTRICAL SHOCK, FIRE, OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in dangerous operation, serious injury, death, or property damage. Improper servicing could result in dangerous operation, serious indury, death, or property damage. Before servicing, disconnect all electrical power to fur- nace. When servici ...

  • Bryant 350MAV - page 2

    CSA B149.1-00 (NSCNGPIC) in Canada; and the Installation Standards, Warm Air Heating and Air Conditioning Systems (NFPA 90B) ANSI/NFPA 90B. In Canada, refer to the CAN/CGA-B/49.1- and .2-M95 National Standard of Canada, Natural Gas and Propane Installation Codes (NSCNGPIC). Wear safety glasses and work gloves. Have a fire extinguisher available dur ...

  • Bryant 350MAV - page 3

    WARNING: Turn off the gas and electrical supplies to the unit before performing any maintenance or service. Follow the operating instructions on the label attached to the furnace. Failure to follow this warning could result in personal injury or death. The minimum maintenance that should be performed on this equipment is as follows: 1. Check and cl ...

  • Bryant 350MAV - page 4

    1. Turn off electrical supply to furnace. 2. Remove main furnace door and blower access panel. 3. Disconnect blower motor wires from furnace control. Field thermostat connections may need to be disconnected depending on their length and routing. 4. Remove control box mounting screws, and position control box, transformer, and door switch assembly t ...

  • Bryant 350MAV - page 5

    7. Remove screws that secure manifold to burner box. (See Fig. 5.) NOTE: Do not remove burner box from cell panel. 8. Remove manifold, orifices, and gas valve as 1 assembly. 9. Remove screws attaching burner assembly in burner box. 10. Remove burner assembly from burner box. NOTE: All burners are attached to burner bracket and can be removed as 1 a ...

  • Bryant 350MAV - page 6

    CAUTION: The ground wire from the gas valve MUST be attached to the burner box attachment screw. Failure to attach this ground wire to an adequate casing ground will cause the furnace control to lock out. NOTE: Be sure burner box gasket is installed between burner box and cell panel. If gasket is damaged, replace it. NOTE: Inspect combustion-air in ...

  • Bryant 350MAV - page 7

    14. Check furnace operation through 2 complete heat operating cycles. Check area below inducer housing, vent pipe, and condensate trap to ensure no condensate leaks occur. If leaks are found, correct the problem. WARNING: FIRE OR EXPLOSION HAZARD Failure to follow the safety warnings exactly could result in serious injury, death, or property damage ...

  • Bryant 350MAV - page 8

    box or inlet pipe, but can be removed without removing either. After removing screw, slide igniter and bracket toward outside of burner box and pull straight out. CAUTION: The igniter is fragile. DO NOT allow it to hit the side of the burner box opening while removing or replacing it. b. Inspect igniter for a white area indicating a crack may be pr ...

  • Bryant 350MAV - page 9

    1. Turn off electrical supply to furnace. 2. Remove main furnace door. 3. Disconnect cap from unused drain tap on inducer housing. (See Fig. 14.) 4. Connect field-supplied 1/2-in. I.D. tube to upper inducer housing drain connection. 5. Insert funnel in drain tube and pour up to 1 quart antifreeze, propylene glycol (RV, swimming pool antifreeze, or ...

  • Bryant 350MAV - page 10

    1. LED flashes a current status code, or code 11, 4 times. Record this status code for further troubleshooting. 2. The inducer will start and continue to run until test is over. 3. Hot surface igniter (HSI) is energized for 15 sec, then de-energized. 4. The blower motor operates on HEATING speed for 10 sec, then turns off. 5. The blower motor opera ...

  • Bryant 350MAV - page 11

    A99118 Fig. 14 — Inducer Housing Drain Tube A99119 Fig. 15 — Funnel in Drain and Antifreeze Running Through Trap — 11 — ...

  • Bryant 350MAV - page 12

    Fig. 16 — Wiring Diagram A02157 PCB TRAN FRS NOTE #11 LS PRS (WHE N USED) LGPS FUSED OR CIRCUIT BREAKER DI SCONNEC T SWI TCH ( WHEN REQ ’ D) NOTE #2 JB L1 L1 BLWR HI/LO TO 115V AC FI ELD DISCONNECT NOTE #2 EQUIP MENT GROUND SPARE- 1 HEAT FA N COOL HSIR EAC-1 START OL HI MED HI MED L O LO BLW M SCHEMATI C DI AGRAM (NA TURAL GAS & P RO P AN E ...

  • Bryant 350MAV - page 13

    Fig. 17 — Service Label A02154 SER VI CE To initiate th e component te st sequence, shut OFF the room thermost at or disconnect the "R" therm ostat lead. Briefl y short the TEST/TWIN ter m inal to the "Com 24V" ter- minal. St atus LED will fl ash code and then tur n ON the i nducer moto r . The inducer motor will run for the e ...

  • Bryant 350MAV - page 14

    A02204a Is LED status light on? Is LED status light blinking rapidly without a pause? Is LED status light blinking ON/OFF slowly with a combination of short and long flashes? Determine status code. The status code is a 2 digit number with the first digit determined by the number of short flashes and the second digit by the number of long flashes? G ...

  • Bryant 350MAV - page 15

    A02204b 11 NO PREVIOUS CODE – Stored codes are erased after 72 hours. On RED LED boards stored status codes can also be erased whene ver pow er (115V or 24V) is interrupted. Run system through a heating or cooling cycle to check system. 12 BLOWER ON AFTER POWER UP – (115V OR 24V) – Normal operation. Blower runs f or 90 seconds, if unit is pow ...

  • Bryant 350MAV - page 16

    © 2002 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 — 16 — Printed in U.S.A. sp0558 Catalog No. 5335-207 ...

メーカー Bryant カテゴリー Furnace

Bryant 350MAVのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 350MAVの取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant 350MAVの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant 350MAVの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant 350MAVの取り付け説明書、サービスマニュアル、簡易説明書、またはBryant 350MAVのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant 350MAVの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant 350MAVデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant 350MAVを使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant 350MAVユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant 350MAVの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant 350MAVの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant 350MAVに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant 350MAVデバイスの基本機能を使うにあたってのヒント。 Bryant 350MAVのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant 350MAVに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant 350MAVのメーカー/サービスへの連絡先に関する情報。

Bryant 350MAVについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant 350MAVの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant 350MAVで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)