  • Golden Blount 18" - 24" & 30" - page 1

    INST ALLA TION AND OPERA TING INSTRUCTIONS FOR VENT -FREE OR VENTED INST ALLA TIONS GOLDEN BLOUNT “TEXAS FLAME II” GAS LOGS N A TURAL GAS OR L.P . 18“ - 24“ & 30“ SIZE SETS The Golden Blount vent-free gas log sets comply with the National Saf ety Standards and are tested and design cer tified b y CSA to ANSI Z21.11.2-2000, un v ented ...

  • Golden Blount 18" - 24" & 30" - page 2

    IMPOR T ANT! Read all instructions carefully bef ore starting installation. F ailur e to follo w these instructions may result in pr operty damage, personal injury or possible loss of life SAFETY AND GENERAL INFORMA TION • Use correct gas type for y our appliance. Do not conv er t from one gas type to another . • If this appliance is for use wi ...

  • Golden Blount 18" - 24" & 30" - page 3

    CAUTION SET SIZE FIREPLA CE WIDTH DEPTH OPENING HEIGHT FRONT BA CK 18" 24" 18" 14" 20" 24" 30" 21 1/2" 16" 21" 30" 36" 30" 16" 21" NO TE! CARBON MONO XIDE POISONING MA Y LEAD T O DEA TH. Early signs of carbon monoxide poisoning resemb le the flu, with headache , dizziness an ...

  • Golden Blount 18" - 24" & 30" - page 4

    BURNER SYSTEM INST ALLA TION Model GB-TFII-18 GB-TFII-18 GB-TFII-24/30 GB-TFII-24/30 Gas T ype Natural L. P . Natural L. P . Max Input 30,000btu/hr 30,000btu/hr 38,000btu/hr 35,000btu/hr Min Input 19,000btu/hr 26,000btu/hr 22,700but/hr 28,500btu/hr Gas Inlet Pressure Maximum 10.5 IN. wc 14.0 IN. WC 10.5 IN. WC 14.0 IN. WC Minimum 5.0 IN. WC 11.0 IN ...

  • Golden Blount 18" - 24" & 30" - page 5

    PLA CEMENT OF LOGS - 18” SETS Front ember log sits under front ember burner tube as shown. Bottom back log is to be placed on back of grate and against burner support brackets as illustrated. Notches in bottom log will go over grate bar . Bottom front log is to be placed on front of grate and against front uprights as illustrated. Front log shoul ...

  • Golden Blount 18" - 24" & 30" - page 6

    PLA CEMENT OF LOGS - 24” & 30” SETS 6 Front ember log sits under front ember burner tube as shown. Bottom back log is to be placed on back of grate and against burner support brackets as illustrated. Notches in bottom log will go over grate bar . Bottom front log is to be placed on front of grate and against front uprights as illustrated. F ...

  • Golden Blount 18" - 24" & 30" - page 7

    FOR Y OUR SAFETY READ BEFORE LIGHTING W ARNING: If y ou do not f ollow these instructions exactly , a fire or e xplosion ma y result causing proper ty damage, personal injur y or loss of lif e. A. This appliance is equipped with a push-button piezo ignition de vice which automatically lights the pilot. If the piezo f ails to ignite the pilot, then ...

  • Golden Blount 18" - 24" & 30" - page 8

    LIGHTING INSTR UCTIONS “MILLIV OL T V AL VE” 1. ST OP! Read the saf ety inf or mation pre viously listed abov e. 2. Mak e sure manual shutoff v alve is fully open. 3. Set roc ker s witch to OFF position. 4. Press in and tur n control knob clockwise to the OFF position. 5. W ait five (5) min utes to clear out any gas . Then smell for gas , inclu ...

  • Golden Blount 18" - 24" & 30" - page 9

    TO TURN OFF GAS TO APPLIANCE “MILLIV OL T V AL VE” CONT . SHUTTING OFF HEA TER 1. T ur n control knob cloc kwise to the OFF position. 2. Set roc ker s witch to OFF position Shutting off burner s only (pilot sta ys lit) Y ou ma y shut off burner and keep the pilot lit b y doing one of the f ollowing. 1. T ur n control knob cloc kwise to the PILO ...

  • Golden Blount 18" - 24" & 30" - page 10

    ITEM QU ANTITY DESCRIPTION 1 1 TF-II-18 T OP LEFT LOG 2 1 TF-II-18 T OP RIGHT LOG 3 1 TF-II-18 BO TT OM BACK LOG 4 1 TF-II-18 BO TT OM FRONT LOG 5 1 TF-II-18 FRONT EMBER LOG 6 1 TF-II-24/30 MIDDLE LEFT LOG 7 1 TF-II-24/30 MIDDLE RIGHT LOG 8 1 TF-II-24/30 LEFT FRONT LOG 9 1 TF-II-24/30 RIGHT FRONT LOG 10 1 TF-II-24/30 BO TTOM BA CK LOG (SPECIFY SIZE ...

  • Golden Blount 18" - 24" & 30" - page 11

    TROUBLESHOOTING REFERENCE SYMPT OM POSSIBLE CA USES CORRECTIVE A CTION 1. Pilot will not light with A. Main shutoff valv e closed. 1. Make sure that the shutoff valv e Piezo ignitor located on the pipe supplying gas to the fireplace is open. B. Air in the gas line. 1. Light a match, tur n valv e knob to PILO T position and depress. K e ep match nea ...

メーカー Golden Blount カテゴリー Outdoor Fireplace

Golden Blount 18" - 24" & 30"のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 18" - 24" & 30"の取扱説明書
- Golden Blountの製品カード
- パンフレット
- またはGolden Blount 18" - 24" & 30"の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Golden Blount 18" - 24" & 30"の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Golden Blount 18" - 24" & 30"の取り付け説明書、サービスマニュアル、簡易説明書、またはGolden Blount 18" - 24" & 30"のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Golden Blount 18" - 24" & 30"の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Golden Blount 18" - 24" & 30"デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGolden Blount 18" - 24" & 30"を使用するのを助ける技術的文書のことです。説明書は通常、全てのGolden Blount 18" - 24" & 30"ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Golden Blountの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Golden Blount 18" - 24" & 30"の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGolden Blount 18" - 24" & 30"の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Golden Blount 18" - 24" & 30"に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Golden Blount 18" - 24" & 30"デバイスの基本機能を使うにあたってのヒント。 Golden Blount 18" - 24" & 30"のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Golden Blount 18" - 24" & 30"に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGolden Blount 18" - 24" & 30"のメーカー/サービスへの連絡先に関する情報。

Golden Blount 18" - 24" & 30"についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGolden Blount 18" - 24" & 30"の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGolden Blount 18" - 24" & 30"で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)