Cleveland Range 24CGA10.2の取扱説明書

23ページ 4.11 mb
ダウンロード

ページに移動 of 23

Summary
  • Cleveland Range 24CGA10.2 - page 1

    Part s Manual Floor type Gas Convection S teamer Series: S teamCraf t Model 24CGA10.2 1333 East 179 th Street Cleveland, Ohio 441 10 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www .clevelandrange.com ...

  • Cleveland Range 24CGA10.2 - page 2

    ...

  • Cleveland Range 24CGA10.2 - page 3

    ...

  • Cleveland Range 24CGA10.2 - page 4

    ...

  • Cleveland Range 24CGA10.2 - page 5

    ...

  • Cleveland Range 24CGA10.2 - page 6

    ...

  • Cleveland Range 24CGA10.2 - page 7

    ...

  • Cleveland Range 24CGA10.2 - page 8

    ...

  • Cleveland Range 24CGA10.2 - page 9

    ...

  • Cleveland Range 24CGA10.2 - page 10

    Statement of Re sponsibilities This document is for use by experienced and traine d Qualifie d Cleveland Range, LLC Authorized Service Representatives who are familiar with both t he safety procedure s, and eq uipment they service. Cleveland Range, LLC a ssumes no liability for any death, injury, equipment damage, or property damage resulting from ...

  • Cleveland Range 24CGA10.2 - page 11

    Cle v eland Range Inc. 1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Visit our Web Site at www .clevelandrange.com MODEL :  24-CGA- 10.2 ITEM NUMBER __________________________________________ JOB NAME / NUMBER __________________________________ Cleveland Standard Features ■ Cooking Capacity f or ...

  • Cleveland Range 24CGA10.2 - page 12

    (NOT T O SCALE) SECT . IV PA GE 14 0402 Litho in U.S.A. GAS ELECTRIC COLD W A TER CLEARANCE DRAINA GE 1 1 ⁄ 4 ˝ IPS line size, 3 ⁄ 4 ˝ (13mm) connection 120V -1Phase, 60 Hz. 35 psi minimum RIGHT = 3˝ operating, 1 1 ⁄ 2 ˝ dia. NA TURAL PROP ANE BTU 2 Blowers & Controls 60 psi maximum 12˝ if adjoining wall or Do not connect other Pipin ...

  • Cleveland Range 24CGA10.2 - page 13

    CLEVELAND RANGE GEMINI 24CGA 6.2 AND 24CGA10.2 SEQUENCE OF OPERATIONS Mechanical Timer Starting with the timed manual switch in the tim ed position, and no time on the timer. 1. To turn the unit on, turn the ON/O FF lever clockwise to the ON position • This mechanically closes the drain. • The red “Power On” indicator is energized. • 115 ...

  • Cleveland Range 24CGA10.2 - page 14

    • The fan prover switch makes allowing 24 VAC to the normally open R2 contacts. • The normally open R2 contacts close and 24 VAC is sent to the main coil of the gas valve. • The main burner is ignited and the water heated to steam . • Steam enters the cabinet and the compar tm ent thermostat closes at 193 degrees. • The “Sure Cook” li ...

  • Cleveland Range 24CGA10.2 - page 15

    BUZZER VALVE BLOWER M OTOR MV GAS VALVE DESCALE REQU IR ED INDICAT OR GEMINI GAS - MECHANICAL TIMER 24V IGNITOR PR OVER MV/PV SPARK CONTRO L MOD SINGLE COMP ARTMENT SHOWN DUPLICATE FO R SECOND COM PA R TMENT GND GND SPARK 24V 24V GND R1 PV MV C NO PV TIMER DOOR MAGNETIC 120V TRANSFORM ER ELECTRO-ME CHANICA L OVER TEM P HI LIMIT GENERATO R MANUAL TI ...

  • Cleveland Range 24CGA10.2 - page 16

    WHT WHT/RE D YEL YEL SW1 BLU WHT/RE D GRA RED BLK C BLK NC NO NC SW2 NO C BLU GRN GRN BLK RED RED WHT/RE D BLK TAN TAN PNK 8 7 PRP PRP 3 2 4 5 1 6 BLU HEAT LT BLU ORN WHT 9 FILL H N XL HI C RED WHT 5 MV/PV GND (BNR) 24V (GND) 4 MV 1 PV 3 2 24V 7 6 5 11 10 GRA WHT YEL 2 13 BLU WHT/O RN YEL WHT/O RN BLU WHT/O RN PRP PNK PRP BLK BLK WHT/RE D BLK BLK W ...

  • Cleveland Range 24CGA10.2 - page 17

    GND SPARK CO NTROL MOD GAS VALVE DUPLICAT E FO R SECOND CO M PARTMENT SINGLE COMPARTMENT SH OWN L300096 C TRANSFOR MER ELECTRONI C BLOWER PROVER IGNITOR 24V SPARK GND MV/PV MV PV GND 24V 120V 24V TRANSFOR MER FU TIMER 24 VAC R1 PV R2 C NO MV R1 C NC M BLOWER MOTO R NO NO NC COMMON TO UPPER AN D LO WER COMPARTME NTS GEMINI GAS - ELECTRON IC TIME R D ...

  • Cleveland Range 24CGA10.2 - page 18

    WHT/OR N GEMINI GAS / ELECTRONIC TI MER WHT/RE D BLK BLK 23 25 WHT YEL YEL BLK RED PRP 27 GRA 26 ORN BLK BLK 24 18 BLU BLK 4 LT BLU 5 PV PV/MV MV 2 15 WHT/OR N GRN GRN ORN BLU 1 4 13 27 6 5 89 WHT YEL YEL SPARK 3 GND (BNR) 24V (GND) 24V MV/PV MV PV 22 GRN WHT/OR N YEL YEL YEL BLU PRP 12 GRA RED BLK WHT/RE D 13 BLK RED WHT 7 4 PRP 3 6 2 1 5 8 FILL O ...

  • Cleveland Range 24CGA10.2 - page 19

    Adju st or re place the on/o ff micro swi tch Y es Con nect power t o steamer. No Is the red light on? Is t here power to t he steamer? Is th ere water in the sig ht glass? Y es S ee Steame r won't fi ll. No Has the pilot ig nited? Y es No Do es the steamer s team in manual mod e? Y es R eplace t he timer Y es Is th ere power to the Timed/Manu ...

  • Cleveland Range 24CGA10.2 - page 20

    PROBLE M: 24CG A6 24CGA10 .2 Steamer won't fill with the ha ndle in the on p osition Is t here power to the steamer? Co nnect po wer to the steamer No Is t here water to t he steamer? Y es S upply wa ter to the steamer. No Is ther e 120 VAC b etween the termin als H and N on the watr level b oard? Y es Adju st or repl ace on/off micro switch N ...

  • Cleveland Range 24CGA10.2 - page 21

    Is ther e 120 VAC b etween the term inals Heat and N o n the water lev el board with the the low probe su bmerged? Is ther e 120 VAC bet ween Heat and N termi nals on the water lev el board with a ju mper between termi nal XL and C? No C lean or re place the pr obe assy. Re place water l evel board. No Y es Is ther e 120 VAC acros s the primary of ...

  • Cleveland Range 24CGA10.2 - page 22

    PROBLE M: 24CGA6, 24CGA10 .2 Electronic timer displays "PAUS" and won't count down ST ART Is steam heating th e cooking ca binetabove 192 degr ees (the set te mp of the thermo -switch)? Doe s the timer coun t down when the th ermo-switch is b ypassed? Y es S ee Ste amer won't steam No Re place the elec tronic timer No Re place t ...

  • Cleveland Range 24CGA10.2 - page 23

    Descaling Procedure-SteamCraft Ultra and Gemini Series 1. Turn the unit OFF and open the doors: This will drain and rinse the generato r for about 3 minutes. 2. Turn the unit power back On: The generator will begin to refill with water. 3. Select Timed with the Timed/Manual switch: DO NOT start the timer, since you do not want to heat the water dur ...

メーカー Cleveland Range カテゴリー Electric Steamer

Cleveland Range 24CGA10.2のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 24CGA10.2の取扱説明書
- Cleveland Rangeの製品カード
- パンフレット
- またはCleveland Range 24CGA10.2の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Cleveland Range 24CGA10.2の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Cleveland Range 24CGA10.2の取り付け説明書、サービスマニュアル、簡易説明書、またはCleveland Range 24CGA10.2のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Cleveland Range 24CGA10.2の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Cleveland Range 24CGA10.2デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCleveland Range 24CGA10.2を使用するのを助ける技術的文書のことです。説明書は通常、全てのCleveland Range 24CGA10.2ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Cleveland Rangeの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Cleveland Range 24CGA10.2の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCleveland Range 24CGA10.2の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Cleveland Range 24CGA10.2に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Cleveland Range 24CGA10.2デバイスの基本機能を使うにあたってのヒント。 Cleveland Range 24CGA10.2のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Cleveland Range 24CGA10.2に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCleveland Range 24CGA10.2のメーカー/サービスへの連絡先に関する情報。

Cleveland Range 24CGA10.2についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCleveland Range 24CGA10.2の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCleveland Range 24CGA10.2で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)