Summary
  • APC PMH3XS-B - page 1

    Inst allation and Operation Manual APC Brick Panel Product s PMF3XS-B PMJ3XS-B PMP3XS-B PMH3XS-B PMG3XS-B PML3XS-B ...

  • APC PMH3XS-B - page 2

    The Brick Panel Product Surge Protective Devices (SPD) are designed to deliver specification grade performance at the service entrance, branch panels or other critical locations. Th e APC SurgeArrest ® Branch Panel Mount Products have replaceable multi-pha se modules, a display panel w ith surge counter, LED status indicators, and an audible alarm ...

  • APC PMH3XS-B - page 3

    Installation and Operation Ma nual 3 Precautions ........ .............. .............. .............. .............. .............. .............. ... 4 Introduction .. .............. .............. .............. .............. .............. .............. ......... 6 Unpacking and Preliminary I nspection .......................... ............. ...

  • APC PMH3XS-B - page 4

    4 Installation and Operation Manu al Precautions At end-of-life conditions, Surge Protective Devices ( SPDs) can lose their ability to block power system voltage and attemp t to draw excessive current from the line. This SPD is equipped with overcurrent and overtemperature components that will automatically disconnect th e surge suppression element ...

  • APC PMH3XS-B - page 5

    Installation and Operation Ma nual 5 Table 1: SPD Per Phase I 2 tI appar ent I p I th PM_3XS-B 175 kA 2 seconds 17,000 A RMS 40,000 A RMS 220 A CA UTION LOSS OF SURGE SUPPRESSION • Do not energize the SPDs until the electrical system is completely installed, inspected, tested, and all conductors have be en conn ected and functional, including the ...

  • APC PMH3XS-B - page 6

    6 Installation and Operation Manu al Introduction Thank you for choosing the APC SurgeArrest ® PM_3X Series “Brick” Su rge Protective Device. The APC non-modular Surge Protecti ve Device (SPD) is a high-qual ity, high-en ergy surge attenuation system that ha s been designe d to protect sensitive equipment from damaging transient voltage surges ...

  • APC PMH3XS-B - page 7

    Installation and Operation Ma nual 7 D ANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH • Apply appropriate p ersonal protective equipment (PPE) and foll ow safe electrical wo rk pr act ices. See NFPA 70E. • This equipment must onl y be inst alled and serviced by qualified electrical personnel. • Turn off all power su pplying this equi ...

  • APC PMH3XS-B - page 8

    8 Installation and Operation Manu al Unpacking and Preliminary Inspection Inspect the entire shi pping containe r for damage or sig ns of mishandling before unpacking the device. Remove the packing mate rial and further inspect the device for any obvious shipping damage . If any damage is found and is a result of shipping or handling, immediately f ...

  • APC PMH3XS-B - page 9

    Installation and Operation Ma nual 9 Electrical Voltage Rating Prior to mounting the SPD, verify that th e devi ce has the same voltage rating as the power distribution system in which it is installe d. Compare th e nameplate voltage or model number on the SPD with the namep late of the electrical distribution equipment. The specifier or user of th ...

  • APC PMH3XS-B - page 10

    10 Installation and Operation Manu al Terminals, Wire Size, and Installation Torque Terminals are provided for phase (line), neutral, an d equipment ground connections. The SPD termin als accept a range of 12 AWG (3 mm 2 ) to 2 AWG (34 mm 2 ) copper wire for phase, neutral, and ground conn ectors. Torque connections to the followi ng values. Branch ...

  • APC PMH3XS-B - page 11

    Installation and Operation Ma nual 11 Location of SPD Install Type 2 SPDs on the load side of th e main Overcurrent Protection De vice (OCPD) to comply with NEC Article 28 5 for Type 2 SPDs. Locate the SPD as close as possible to the circuit being ad dressed to minimize the wire length and optimize SPD perfo rmanc e. Avo id long wire runs so th at ...

  • APC PMH3XS-B - page 12

    12 Installation and Operation Manu al Grounding The SPD has leakage current to ground when energized and can present a hazardous touch voltage. The device has SPD elements conne cted from phase to ground. To prevent hazardous touch voltage on the SPD enc losu re during normal operation or during SPD end-of-life , it is critical that there be a robu ...

  • APC PMH3XS-B - page 13

    Installation and Operation Ma nual 13 Installation Conduit Location and Recommendations The recommended conduit entry is at the bottom of the device enclosure. Use a conduit seal that is appropriate for the enclosure rating. Special Enclosure Considerations Removing and Reconnect ing the RJ45 Patch Cables The RJ45 patch cables are marked with match ...

  • APC PMH3XS-B - page 14

    14 Installation and Operation Manu al Wiring Follow the step s listed below when making wi ring connections. 1. Turn off all power supplying this equip ment before working on or i nside any enclosure containing this equipment. 2. Confirm the SPD voltage ra ting and configuration i s the same as th e system voltage and power system co nfiguration to ...

  • APC PMH3XS-B - page 15

    Installation and Operation Ma nual 15 Wiring Diagrams without Integral Switch Figure 3: SIngle-Phase , T hree-Wire, Grou nded Installati on Figure 4: Three-Phase, Three- or Four-Wire, Ground ed Wye Installation Figure 5: Three-Phase, Three- or Four -Wire, High-Leg Delta Installation N 8222-0013-04 SPD A N C Made in U S A / Hecho en E.U.A. / Fabriqu ...

  • APC PMH3XS-B - page 16

    16 Installation and Operation Manu al Operation LED Status Indicators The diagnostic display panel shows the sta tus of the SPD module with diagnostically controlled gree n/red LEDs. If a unit is operating correctly, a ll the phase LEDs will be illumin ated green. To te st the integrity of the diagnostics for each phase, push the button below the p ...

  • APC PMH3XS-B - page 17

    Installation and Operation Ma nual 17 When power is applied to the SPD and one or more of the diagnostic display panel LEDs are red, and one or more modul e LEDs are out, the module sho uld be replaced. Refer to “Maintenance and Tr oubleshooting” on page 19 for prop er troubleshooting procedu res. Audible Alarm Push the alarm enable/disable but ...

  • APC PMH3XS-B - page 18

    18 Installation and Operation Manu al Dry Contacts The SurgeArrest ® series SPDs come standard with dry contacts. The connection for the dry contacts is located on the back of the diagnostic display panel (lower right corner). The dry cont acts are 3-posi tion, Form “C” type with Normally Open, Normally C losed and Common conn ections. In the ...

  • APC PMH3XS-B - page 19

    Installation and Operation Ma nual 19 Maintenance and Troubleshooting Preventive Maintenance Inspect the SPD periodically to main tain reliable system performance and continued transient voltage surge suppression. Periodicall y check the state of the diagnostic displ ay panel LED status ind icators. Routinely use the built-in diagnostics to inspect ...

  • APC PMH3XS-B - page 20

    20 Installation and Operation Manu al Troubleshooting If a module shows two gree n indicator lights and the di splay panel shows a red phase indicator light, follow the Troubl eshooting Flow Chart in Figure 9 below. Replac ement Pa rts The following replacement part s are available. For orderi ng information re fer to the product catalog. • SPD m ...

  • APC PMH3XS-B - page 21

    Installation and Operation Ma nual 21 ...

  • APC PMH3XS-B - page 22

    22 Installation and Operation Manu al ...

  • APC PMH3XS-B - page 23

    Installation and Operation Ma nual 23 ...

  • APC PMH3XS-B - page 24

    APC Worldwide Customer Support Customer support for this or other APC products is available at no charge in the fo llowing ways: • Visit the APC website to access documents in the APC Kn owledge Base and to submit customer support requests. — www.apc.com (Corporate Headquarters) Connect to localized APC Web sites fo r spe cific countries, ea ch ...

メーカー APC カテゴリー Surge Protector

APC PMH3XS-Bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PMH3XS-Bの取扱説明書
- APCの製品カード
- パンフレット
- またはAPC PMH3XS-Bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、APC PMH3XS-Bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、APC PMH3XS-Bの取り付け説明書、サービスマニュアル、簡易説明書、またはAPC PMH3XS-Bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、APC PMH3XS-Bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

APC PMH3XS-Bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAPC PMH3XS-Bを使用するのを助ける技術的文書のことです。説明書は通常、全てのAPC PMH3XS-Bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

APCの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. APC PMH3XS-Bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAPC PMH3XS-Bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。APC PMH3XS-Bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. APC PMH3XS-Bデバイスの基本機能を使うにあたってのヒント。 APC PMH3XS-Bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。APC PMH3XS-Bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAPC PMH3XS-Bのメーカー/サービスへの連絡先に関する情報。