SPX Cooling Technologies 92-1322Cの取扱説明書

16ページ 0.22 mb
ダウンロード

ページに移動 of 16

Summary
  • SPX Cooling Technologies 92-1322C - page 1

    / Mar le y Electr ic Basin Heat er / User Manual 92-1322C ...

  • SPX Cooling Technologies 92-1322C - page 2

    ...

  • SPX Cooling Technologies 92-1322C - page 3

    3 / Receiving and Inspection / The heater package is shipped directly fr om the vendor . 1. Check all parts for any damage in transit. The carrier is responsible for the condition of the heater package upon arrival. If damage is appar - ent, note the fr eight bill accordingly . This will support your claim with the freight carrier . 2. Check the na ...

  • SPX Cooling Technologies 92-1322C - page 4

    4 / Intr oduction / The purpose of a basin heater is to prevent water freezing in the cooling tower basin during periods of shutdown or standby operation. The heater system is sized according to tower model and location to give maximum protection against water freezing in the cold water basin. This heating system is not intended to protect the towe ...

  • SPX Cooling Technologies 92-1322C - page 5

    5 / Installation / For detailed information concerning installation, refer to the heater installation drawing provided with the cooling tower . Heater Element Install the heater element(s) in the depr essed area of the cold water basin near the outlet. Provide clearance of 7 ⁄ 8 " or more above the floor . A single centrally located heater ...

  • SPX Cooling Technologies 92-1322C - page 6

    6 / Installation / Control Panel The contr ol panel is suitable for outdoor mounting, and may be mounted on the tower , but not inside the tower . Wir e the heaters to the panel. Wir e the panel to the branch circuit supplying power to the heater . The field supplied branch cir cuit disconnect switch and the branch cir cuit protective device (fusi ...

  • SPX Cooling Technologies 92-1322C - page 7

    7 / Installation / T emperature / W ater Level Sensor Assembly This basin heater package is equipped with a combination tempera- ture/liquid level sensor and may have a thermal cutoff switch. Both are safety devices that must not be altered or changed in any man- ner . Disabling either safety feature may result in combustion and/ or fire, which co ...

  • SPX Cooling Technologies 92-1322C - page 8

    8 / Oper ation / SOLID S TA TE RELA Y CARD PROBE BASIN RED CT N G2 G1 T2 T1 SH 120 RED 240 24 COM NC NO BLK RED BLK SHIELD LED INDICA TORS GREEN Figure 1 T able 3 Red Green OFF OFF Ready , No Demand ON OFF Low W ater Level OFF ON Heater On Operating Instructions T o operate the heater system, visually check that the water level is above the sensor ...

  • SPX Cooling Technologies 92-1322C - page 9

    9 T esting above Freezing T emperatures Under normal operating conditions the heaters will be turned on at a water temperatur e between 40° and 45°F , and tur ned of f when the water temperature exceeds 45°F . For testing the system at temperatures above 45°F there ar e two methods as follows: Method A 1. Disconnect power to the control panel u ...

  • SPX Cooling Technologies 92-1322C - page 10

    10 Method B 1. Disconnect power to the heater contr ol panel using standard lockout procedur es for safety . 2. Drain basin until the water level is below the probe allowing r emoval of the probe. Make sur e water still covers the heater elements. 3. Place the pr obe in a container of ice water making sure both metal parts of the probe ar e submerg ...

  • SPX Cooling Technologies 92-1322C - page 11

    11 SOLID S TA TE RELA Y CARD PROBE BASIN RED CT N G2 G1 T2 T1 SH 120 RED 240 24 COM NC NO BLK RED BLK SHIELD JUMPER GREEN Figure 3 Caution Deicing If the temperature/water level sensor assembly becomes encased in ice the heaters will not operate. Ice provides inadequate conductivity for the sensor pr obe to detect operational water level. T o opera ...

  • SPX Cooling Technologies 92-1322C - page 12

    12 / T r oubleshooting / Please refer to the Caution statement on Page 6 and the Warning statement on Page 7 of this manual before performing the following T roubleshooting procedures. If the system fails to operate, check the following: 1. Check water temperature. Systems will turn on between 40° and 45°F and turn off above 45°F . 2. Check wate ...

  • SPX Cooling Technologies 92-1322C - page 13

    13 2. If the contactor does not operate, check voltage across terminal N on the cir cuit board and NO on the r elay mounted on the circuit board —21-29 volt requir ed. If voltage is present across the coil—N to NO— the contactor coil is defective and the contactor must be replaced. If voltage is not present, the circuit board relay is defecti ...

  • SPX Cooling Technologies 92-1322C - page 14

    14 1 T ransformer 120V/24V .............................................. B52465D T ransformer 208V/24V .............................................. A79270D T ransformer 240V/24V .............................................. B91566D T ransformer 480V/24V .............................................. B09608D T ransformer 600V/24V ............... ...

  • SPX Cooling Technologies 92-1322C - page 15

    ...

  • SPX Cooling Technologies 92-1322C - page 16

    7401 WEST 129 STREET | OVERLAND PARK, KANSAS 66213 UNITED STATES | 913 664 7400 | spxcooling@spx.com | spxcooling.com In the interest of technological progress, all products are subject to design and/or material change without notice. ©2008 SPX Cooling Technologies, Inc. | Printed in USA Manual 92-1322C ...

メーカー SPX Cooling Technologies カテゴリー Electric Heater

SPX Cooling Technologies 92-1322Cのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 92-1322Cの取扱説明書
- SPX Cooling Technologiesの製品カード
- パンフレット
- またはSPX Cooling Technologies 92-1322Cの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、SPX Cooling Technologies 92-1322Cの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、SPX Cooling Technologies 92-1322Cの取り付け説明書、サービスマニュアル、簡易説明書、またはSPX Cooling Technologies 92-1322Cのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、SPX Cooling Technologies 92-1322Cの製品を使用するにあたって最も人気のある説明書を閲覧できます。

SPX Cooling Technologies 92-1322Cデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSPX Cooling Technologies 92-1322Cを使用するのを助ける技術的文書のことです。説明書は通常、全てのSPX Cooling Technologies 92-1322Cユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

SPX Cooling Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. SPX Cooling Technologies 92-1322Cの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSPX Cooling Technologies 92-1322Cの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。SPX Cooling Technologies 92-1322Cに関してこのドキュメントで見つけることができる全てのヒントの目次
3. SPX Cooling Technologies 92-1322Cデバイスの基本機能を使うにあたってのヒント。 SPX Cooling Technologies 92-1322Cのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。SPX Cooling Technologies 92-1322Cに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSPX Cooling Technologies 92-1322Cのメーカー/サービスへの連絡先に関する情報。

SPX Cooling Technologies 92-1322Cについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSPX Cooling Technologies 92-1322Cの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSPX Cooling Technologies 92-1322Cで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)