American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 1
- IMPORTANT! This housing meets IP66/Nema 4 ratin gs provided it is used with a pro perly installed ROENDC End Cap Assembly and one of the following mount s: RHOTR Over-the-Roof Mount, RHOSW Short Wall Mount, or RHOLW Long Wall Mount. ADSDUHOC, ADSDUHOS, ADSDUHOVRC, ADSDUHOVRS SpeedDome ® Ultra Outdoor Housing Installation Guide Before performing ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 2
Page 2 of 12 8200-0492-02, Rev. C Set the dome address. The address range is from 001 to 255, except for Manchester, which is 01 to 64. Set switches. Example: For address 107, set SW3 to 1, SW2 to 0, and SW1 to 7. SW3 SW2 SW1 IMPORTANT! Both the outdoor housing and dome camera are shipped “terminated” for when they are installed at the end of a ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 3
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 3 of 12 S peedDome ® Ultra Out door Housing Installation Guide–Continuation ADSDUHO C ADSDUHOS ADSDUHOV RC ADSDUHOV RS Contents: To the Installer ....................................................... 3 About the Product....................................... ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 4
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 4 of 12 Warnings and Cautions Please review the following warning s and cautions before you begin installation or service. Warnings WARNING! Always use proper lift and safety equipment for the location and type of installation. Use the safety features of the lift ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 5
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 5 of 12 Preventing Condensation Damage, missing parts, or procedures that most often allow water to enter the housing are as follows (refer to figures opposite): Missing O-ring on cover, or missing sleev e or seal on end cap assembly Missing Teflon tape a ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 6
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 6 of 12 Connector Pin Assignments GREEN CONNECTOR (POWER) Pin Color Desc ription 1 Black 24Vac 2 Red Common 3 White 24Vac BLACK CONNECTOR (DATA) Manchester Pin Color* Designation 1-4 — Not used. 5 White/Orange Manchester (White) 6 White/Yellow Manchester (Black ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 7
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 7 of 12 Housing Termination and Video Configuration Both the outdoor housing and dome camera are shipped “terminated” for when they are installed at the end of a data cable. Should the cable continue to another dome, “unter minate” the housing using the f ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 8
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 8 of 12 4. On the circuit board is a mark (shown below). To reattach the board to the housing, match the mark to an identical mark on the base and sn ap the board in place. 5. Gently remove the dust cover. Note: Keep the cover and use it to protect contacts shoul ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 9
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 9 of 12 Troubleshooting This section covers what to do whe n: • Dome does not respond to commands • Fans do not turn • Picture is grainy or discolored • Poor video • Ice forms on bubble. CAUTION: Some step s in this sect ion involve tightening wire conn ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 10
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 10 of 12 SensorNet Data Connections Pin Color Designation 1-4 — Not used. 5 White/Orange SensorNet (unshielde d) 6 White/Yellow SensorNet (unshiel ded) 4. Chec k fans. Are they on? - YES: Continue. - NO: Go to “Fans Do Not Turn” procedure next. 5. Check vid ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 11
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 11 of 12 Ice Forms On Bubble Follow steps until the problem is correct ed. See page 5 to order parts. 1. Are blower/heater fans in the housing working? If not, see “Fans Do Not Turn” opposite. 2. Is the camera dome receiving power? Lo ok for evidence such as ...
-
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC - page 12
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C INSTALLATION GUIDE - CONTINUATION 12 of 12 Declarations Regulatory Compliance REG ID: SV SDUO Emissions .............................. 47 CFR, Part 15, Class A ICES-003 CISPR 22, Class A Immunity ...................................................... EN50130-4 Safety ............................. ...
American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOCについてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもAmerican Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOCの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmerican Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOCで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。