    Part No. F40BP73920000 Form No. BP7392 U.L. Model No.: CF701 READ AND SA VE THESE INSTRUCTIONS BUILDER UNIP ACK ™ Net Weight: 19.4 Lbs. 52” Ceiling Fan Owner's Manual LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmans ...

  • Emerson CF701ORB00 - page 2

    WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. ...

  • Emerson CF701ORB00 - page 3

    1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. Five fan blades c. One ceiling cover d. Five blade flanges e. One hanger ball/downrod assembly f. One hanger bracket g. One switch housing assembly h. Two 60-watt candelabra bulbs ...

  • Emerson CF701ORB00 - page 4

    How to Put Y our Ceiling Fan T ogether 1. Pass the 42" motor leads through the opening in the ceiling cover. Be sure the cover is oriented correctly. 2. Separate, untwist and unkink the three motor leads. Route the motor leads through the hanger ball/downrod assembly. 3. Loosen the two setscrews in the motor coupling. Align the clevis pin hole ...

  • Emerson CF701ORB00 - page 5

    5 U.L. Model No.: CF701 SWITCH HOUSING ASSEMBL Y SWITCH HOUSING CONNECTOR MOTOR CONNECTOR SWITCH HOUSING MOUNTING SCREW Figure 6 9. Remove the center plug screw from the switch housing assembly (Figure 4). Remove and retain the two wire connectors. 10. Remove and retain the lockwasher and nut from the light fitter. Insert the black and white wires ...

  • Emerson CF701ORB00 - page 6

    6 To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket. W ARNING ! Electrical Requir ements If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture. Your new ceiling fan will require a grounded ...

  • Emerson CF701ORB00 - page 7

    7 If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Se ...

  • Emerson CF701ORB00 - page 8

    3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket. 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 13). 5. Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplie ...

  • Emerson CF701ORB00 - page 9

    9 IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Abrasive cleaning agents are not required and should be avoided to prevent damage to finish. Maintenance Accessories Do not use w ...

  • Emerson CF701ORB00 - page 10

    10 U.L. Model No.: CF701 Model No. Key N o. Description CF701BS00 CF701ORB00 CF701WW00 * Hanger Pack Assembly, 760750-24 760750-48 760750-3 Consisting of: 1 Hanger Bracket — — — 2 Hanger Ball/ Downrod Assembly — — — 3 Ceiling Cover 763103-BS 763103-ORB 763103-WW 4 Light Fitter 763899 763899 763899 5 Glass Bowl 763900 763900 763900 6 Cov ...

  • Emerson CF701ORB00 - page 11

    11 U.L. Model No.: CF701 Repair Par ts Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-800-654-3545. 7 8 3 2 10 11 9 17 18 14 1 ...

  • Emerson CF701ORB00 - page 12

    Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 U.L. Model No.: CF701 Form No. BP7392 Printed in China 02/09 Part No. F40BP73920000 ...

メーカー Emerson カテゴリー Fan

Emerson CF701ORB00のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CF701ORB00の取扱説明書
- Emersonの製品カード
- パンフレット
- またはEmerson CF701ORB00の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson CF701ORB00の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson CF701ORB00の取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson CF701ORB00のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson CF701ORB00の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Emerson CF701ORB00デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson CF701ORB00を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson CF701ORB00ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emersonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson CF701ORB00の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson CF701ORB00の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson CF701ORB00に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson CF701ORB00デバイスの基本機能を使うにあたってのヒント。 Emerson CF701ORB00のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson CF701ORB00に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson CF701ORB00のメーカー/サービスへの連絡先に関する情報。

Emerson CF701ORB00についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson CF701ORB00の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson CF701ORB00で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)