  • Omega DPF500 Series - page 1

    omega.com e-mail: info@omega.com Fo r la te st p ro du ct m an ua ls : omegamanual.info D P F 5 0 0 S e r i e s R a t e m e t e r / T o t a l i z e r Shop online at U ser ’ s Guide ...

  • Omega DPF500 Series - page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canad ...

  • Omega DPF500 Series - page 3

    T able of Contents i Page Chapter 1 Introduction 1.1 Unpacking ...................................................................................................................... 1 1.2 Description ..................................................................................................................... 1 1.3 Features ................. ...

  • Omega DPF500 Series - page 4

    ii THIS P AGE INTENTIONALL Y BLANK ...

  • Omega DPF500 Series - page 5

    1 Chapter 1 Introduction 1.1 Unpacking Remove the Packing List and verify that you have received all equipment. If you have any questions about the shipment, please call OMEGA Customer Service Department. When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immed ...

  • Omega DPF500 Series - page 6

    2 Chapter 2 Installation 2.1 Battery Installation: All DPF500 models are shipped without the battery(ies) installed. This preserves battery life when the unit is not in service. When using external DPF5-BP , mount within 12" and plug connector into 3 position square posts (see Fig 1). Polarity is not a concern because center is common. T o ins ...

  • Omega DPF500 Series - page 7

    3 DPF503 DPF502 DPF501 DPF5-BP Accessory 2.3 Dimensions Dimensions are in inches (mm) Dimensions are in inches (mm) Dimensions are in inches (mm) Dimensions are in inches (mm) 4.92 (125) 4.33 (1 10) 4.33 (110) #8 Screw Mounting holes molded directly under cover screws. Max. screw head .29" (T yp. 4 places) E M .98 (25) 1.97 (50 ) .1 8 ( 5) .43 ...

  • Omega DPF500 Series - page 8

    4 Severa l typical applicati ons of the DPF500 are shown below . Please observe that the various pulse inputs and power options may be intermixed in many ways to solve common applications. The isolated pulse output may be freely used so long as proper polarity is observed. Caution : When 4-20 mA loop option is provided, the power wiring to the loop ...

  • Omega DPF500 Series - page 9

    5 Chapter 3 20 Point Linearization (-LIN option) 3.1 20 Point Linearization Operation (-LIN option) A 20 point linearization table is used to construct a curve describing the relationship of K-Factor and input frequency . The measured input frequency is used to access the table. A linear interpolation of adjacent point pairs is used to arrive at th ...

  • Omega DPF500 Series - page 10

    6 4.1 Explanation of Display Prompts (continued) fr# : (frequency for point #) This prompt will only appear when 20 point selected. It sets the frequency for each of the 20 points (#). Press the ↑ key to increment each digit. Press the ← key to step to the next digit to the left. Press the E key to enter the desired frequency for point #. faC# ...

  • Omega DPF500 Series - page 11

    7 4.1 Explanation of Display Prompts (continued) oUt HI : (out high) Sets the high setting for the 4-20 mA analog output. Key in the high rate value at which the unit will output 20 mA. Press the ↑ key to increment each digit. Press the ← key to step to the next digit to the left. Press the E key to enter the displayed out hi value. pUlscale : ...

  • Omega DPF500 Series - page 12

    8 4.2 Programming Flowchart RA TE RA TE RA TO T A L CLR ToT FDEC 12345678 M RUN MODE CLEAR T OT AL OT AL OT F ACT OR DECIMAL FAC 100 F ACT OR 0000 ent Code ENTER CODE If panel lock ON If panel lock OFF If code correct If code incorrect FAC 20poInt F ACT OR TYPE 20poInt lInear lInear selected E M E E M E M E M 20poInt selected Continue On Next Page ...

  • Omega DPF500 Series - page 13

    9 4.2 Programming Flowchart (continued) Press the key to step the totalizer decimal to the desired location. Press the E key to enter the displayed decimal location. Press the M key to skip and keep the existing location Press the key to step to the desired totalizer descriptor . Press the E key to enter the displayed descriptor . Press the M key t ...

  • Omega DPF500 Series - page 14

    10 Chapter 5 Operation 5.1 General A suitable pulse producing device or fl ow meter is wired to one of the three pulse inputs provided on the DPF500. Only one of these inputs is used in a given application. There are no connections to the two unused pulse inputs. Isolated magnetic pickups may be connected to terminals 1 and 2. Isolated contact clo ...

  • Omega DPF500 Series - page 15

    1 1 Chapter 6 Error Messages / Analog Output Calibration 6.1 Error Messages The DPF500 is provided with extensive self checking which assists the user in the location of setup entry errors and in reporting malfunctions or unusual operating conditions. When an error occurs, the display will fl ash. Press any key to see the error message correspondi ...

  • Omega DPF500 Series - page 16

    12 Chapter 7 Specifi cations ENVIRONMENT AL: OPERA TING TEMPERA TURE -4°F (-20°C) to + 158°F (70°C) Extended T emp: -22°F (-30°C) to + 158°F (70°C) HUMIDITY 0 - 90% Noncondensing MOUNTING STYLES: 1 - Panel Mount - NEMA 4X Front 2 - W all Mount - NEMA 4X Enclosure (keypad mounted behind clear cover) 3 - Explosion Proof - Class I, Division I ...

  • Omega DPF500 Series - page 17

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s custo ...

  • Omega DPF500 Series - page 18

    M 1896 / 0 7 05 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, ...

メーカー Omega カテゴリー Calculator

Omega DPF500 Seriesのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DPF500 Seriesの取扱説明書
- Omegaの製品カード
- パンフレット
- またはOmega DPF500 Seriesの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega DPF500 Seriesの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega DPF500 Seriesの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega DPF500 Seriesのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega DPF500 Seriesの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega DPF500 Seriesデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega DPF500 Seriesを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega DPF500 Seriesユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omegaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega DPF500 Seriesの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega DPF500 Seriesの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega DPF500 Seriesに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega DPF500 Seriesデバイスの基本機能を使うにあたってのヒント。 Omega DPF500 Seriesのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega DPF500 Seriesに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega DPF500 Seriesのメーカー/サービスへの連絡先に関する情報。

Omega DPF500 Seriesについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega DPF500 Seriesの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega DPF500 Seriesで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)