Paradyne 3161 CSUの取扱説明書

19ページ 0.26 mb
ダウンロード

ページに移動 of 19

Summary
  • Paradyne 3161 CSU - page 1

    ACCULINK 3161 DSU/CSU QUICK REFERENCE Document No. 3161-A2-GL1 1-40 ...

  • Paradyne 3161 CSU - page 2

    Copyright  1998 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law . No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, m ...

  • Paradyne 3161 CSU - page 3

    TM 1 ACCULINK 3161 DSU/CSU Quick Reference Document Number 3161-A2-GL1 1-40 February 1998 Quick Start Procedur e The following procedure is for experienced DSU/CSU users who are familiar with the 3161 DSU/CSU installation process and have no special requirements for their application. See the ACCULINK 316x Data Service Unit/Channel Service Unit Ope ...

  • Paradyne 3161 CSU - page 4

    2 3. Attach the network cable to the Auxiliary Backplane using either a 50-pin cable or the T1 Network Interface Adapter . Connect the other end of the network cable to the connection provided by the telephone company . 496-14386-0 3 Auxiliary Backplane over Slots 9–16 COMSPHERE 3000 Series Carrier (Rear) T1 Network Cable Cable Retainer 4. T urn ...

  • Paradyne 3161 CSU - page 5

    3 5. Insert the DSU/CSU circuit card into the appropriate slot in the carrier . The power-up self-test begins. 495-1479 7 6. If you intend to use front panel emulation, connect the cable from the PC to Port 2 on the Auxiliary Backplane using the COM port adapter and COM-port-to-PC cable. 7. If you do not intend to use the DTE Drop/Insert T1 port, d ...

  • Paradyne 3161 CSU - page 6

    4 Configuration Options Configuration options are accessed from the Cnfig branch of the front panel menu. DSU ESF Stat 97-15577 Dev HS S T est Pe r f TS t a t LE D ID T1 Prtn Pr tn User T elco Cur 24T ot Intvl Far Near Cur 8T ot Intvl T est R lpbk Lpbk Pt rn s La mp QRSS 51 1 Abort Mon LLBUP LLBDN 54UP 54DN FT1UP FT1DN PLB DLB RLB LLB Abort DCLB DT ...

  • Paradyne 3161 CSU - page 7

    5 T able 1. DTE Interface Configuration Options Option Factory 1 Factory 2 Comments/Description DTE Port: Enab Enab Enables the use of the DTE DTE Port: Disab Disab Enables the use of the DTE Drop/Insert port. DTE Framing: D4 D4 Selects D4 or ESF framing format DTE Framing: ESF ESF Selects D4 or ESF framing format. DTE Coding: AMI AMI Selects AMI o ...

  • Paradyne 3161 CSU - page 8

    6 T able 2. Port Configuration Options (2 of 3) Option Comments/Description Factory 2 Factory 1 Disab Disab Port LB: DTLB DTLB Port-initiated Loopbacks, allows Loopbacks to be initiated through Port LB: DCLB DCLB p, Loopbacks to be initiated through the port by the external DTE. Both Both ep o b y ee e a Disab Disab All Ones: DTR DTR All ones sent ...

  • Paradyne 3161 CSU - page 9

    7 T able 2. Port Configuration Options (3 of 3) Option Comments/Description Factory 2 Factory 1 Far end: Disab Disab Specifies whether the device will maintain far end performance Far-end: Maint Maint p maintain far-end performance statistics. Mgmt Link: Enab Enab S p ecifies whether the EDL Mgmt Link: Disab Disab S pec ifi es w h e th er th e EDL ...

  • Paradyne 3161 CSU - page 10

    8 T able 4. DTE Drop/Insert Port Channel Configuration Options Line 1 Displays: Line 2 Displays: Meaning Comments/Description — Unassigned N1 N2 N3 ...... N24: D1, D2 ... D24 Channel assigned to this DTE channel Function key under the channel (N1, N2, etc.) selects the DTE channel to assi g n ( D1 , D2 , ... D24 , N1 N2 N3 ...... N24 : Prt1 Prt2 ...

  • Paradyne 3161 CSU - page 11

    9 T able 5. Data Port Channel Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description NET NET Assigns this port to channels on Assign T o: DTE DTE Assigns this port to channels on the Network or DSX-1 T1 interface, tt h t Assign T o: Prt n Prt n the Network or DSX 1 T1 interface, or to another port. Block Block Determines how ...

  • Paradyne 3161 CSU - page 12

    10 T able 5. Data Port Channel Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description Clear Clear Clears (unassigns) channels for this port. Start At: N1 (D1) N2 (D2) N3 (D3) N4 (D4) N5 (D5) N6 (D6) N7 (D7) N8 (D8) N9 (D9) N10 (D10) N1 1 (D1 1) N12 (D12) N13 (D13) N14 (D14) N15 (D15) N16 (D16) N17 (D17) N18 (D18) N19 (D19) N ...

  • Paradyne 3161 CSU - page 13

    11 T able 6. General Configuration Options Option Factory 1 Factory 2 Comments/Description Gen Y ellow: Enab Enab Y ellow alarm is g enerated b y the G en Y e ll ow: (Generate Y ellow) Disab Disab Y e ll ow a l arm i s genera t e d b y th e DSU/CSU on LOS, LOF , or AIS. NET NET DTE DTE Selects the clock source to be Clock Src: Prt1 Prt1 Selects the ...

  • Paradyne 3161 CSU - page 14

    12 T able 7. User Configuration Options (1 of 3) Option Factory 1 Factory 2 Comments/Description Self - T est: Enab Enab Allows bypass of self-test on Self-T est: Disab Disab Allows bypass of self - test on initialization. Dial - In: Enab Enab Controls whether dial-in access is Dial-In: Disab Disab Controls whether dial - in access is allowed. Pass ...

  • Paradyne 3161 CSU - page 15

    13 T able 7. User Configuration Options (2 of 3) Option Comments/Description Factory 2 Factory 1 1.2 1.2 2.4 2.4 Com Rate: 4.8 4.8 Com Rate: (Communication Port Rt) 9.6 9.6 Selects the bit rate for the COM p ort. (Communication Port Rate) 14.4 14.4 por t . 19.2 19.2 38.4 38.4 Char Length: 7 7 Selects the character length for the Char Length: 8 8 Se ...

  • Paradyne 3161 CSU - page 16

    14 T able 7. User Configuration Options (3 of 3) Option Comments/Description Factory 2 Factory 1 5 5 TnDiscTm: ( T elnet Disconnect Up Up The period of inactivity (1 to 60 minutes ) that causes a (T e l ne t Di sconnec t T ime) Down Down 60 m i nu t es ) th a t causes a disconnect if TnInActTm is enabled. Save Save ena bl e d . T able 8. Alarm Conf ...

  • Paradyne 3161 CSU - page 17

    15 T able 8. Alarm Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 AlrmRelay: Enab Enab Specifies whether to activate the AlrmRelay: (Alarm Relay) Disab Disab Specifies whether to activate the alarm relay on an alarm condition. T able 9. General Management Configuration Options (1 of 2) Option Factory 1 Factory 2 Comm ...

  • Paradyne 3161 CSU - page 18

    16 T able 9. General Management Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 IP Adr: Edit Edit The IP address needed to access IP Adr: Clear Clear The IP address needed to access the device. NetMask: Edit Edit The Subnet Mask needed to NetMask: Clear Clear The Subnet Mask needed to access the device. Com IP Adr: Ed ...

  • Paradyne 3161 CSU - page 19

    17 T able 10. Management T rap Configuration Options Option Factory 1 Factory 2 Comments/Description Num T rap Mgrs: 1 2–6 1 2–6 The number of trap managers supported by the device. T rap n IP Adr: Edit Edit Specifies the IP address for each trap manager . This configuration T rap n IP Adr: Clear Clear trap manager . This configuration option i ...

メーカー Paradyne カテゴリー Network Card

Paradyne 3161 CSUのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3161 CSUの取扱説明書
- Paradyneの製品カード
- パンフレット
- またはParadyne 3161 CSUの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Paradyne 3161 CSUの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Paradyne 3161 CSUの取り付け説明書、サービスマニュアル、簡易説明書、またはParadyne 3161 CSUのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Paradyne 3161 CSUの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Paradyne 3161 CSUデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがParadyne 3161 CSUを使用するのを助ける技術的文書のことです。説明書は通常、全てのParadyne 3161 CSUユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Paradyneの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Paradyne 3161 CSUの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははParadyne 3161 CSUの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Paradyne 3161 CSUに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Paradyne 3161 CSUデバイスの基本機能を使うにあたってのヒント。 Paradyne 3161 CSUのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Paradyne 3161 CSUに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるParadyne 3161 CSUのメーカー/サービスへの連絡先に関する情報。

Paradyne 3161 CSUについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもParadyne 3161 CSUの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがParadyne 3161 CSUで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)