    No. EJL- 106A Density (Consistency) Meter LQ500 Introduction The LQ500 density (consistency) meter uses microwave phase shift technology to determine concentrations of solids in the material to be measured flowing through pipes. It can perform a stable and realtime density (consistency) measurement because this technology is not affected by flow ve ...

  • Toshiba Density (Consistency) Meter LQ500 - page 2

    LQ500 2 range, which is the upper limit setting range. Resolution: Meter size 50 mm (2”) 80 mm (3”)to 300 mm (12”) Resolution 0.002%TS 0.001%TS Note 1: Above values are the results of comm uting ability in the phase measurements of the converter. Note 2: Density (consistency) determination resolution for sample reagen t; Meter size 50 mm (2? ...

  • Toshiba Density (Consistency) Meter LQ500 - page 3

    LQ500 3 200 mm (8”) 8 mS/cm maximum 250 mm (10”) 8 mS/cm maximum 300 mm (12”) 6 mS/cm maximum Note 1: The LQ500 can not have an accurate density (consistency) me asurement when it is over the specification according to reduce the microwave s ignal. Note 2: The LQ500 density (consistency) m easurement for applicat ion whe re liquids containi n ...

  • Toshiba Density (Consistency) Meter LQ500 - page 4

    LQ500 4 hours when programming every 5 minutes. • Moving average function: In order to keep the average density (consistency) output, or in order to suppress the deflection width of the output. It helps for densit y (consistency) control. <Specification> Enable to determine a number from 1 to 99. • Change-rate limit function: In order to ...

  • Toshiba Density (Consistency) Meter LQ500 - page 5

    LQ500 5 11 0 (4.3”) (1 19) (4.7”) Converter commu nicatio n port Steel pipe (50A) (2”) 360 (14.2”) 390 (15.4”) 234 (9.2”) Contact sign al I/O port (1) Contact sign al I/O port (2) Densi ty signal output po rt Reserve d Grounding t erminal In the case of W all mounting In the cas e of 50A (2”) mountin g Steel pipe U bolt (M10) Converte ...

  • Toshiba Density (Consistency) Meter LQ500 - page 6

    LQ500 6 (7) Install an adjustable piping mechanism if there is a possibility that the detector pipe m ay not fit between mating flanges. (8) Install the LQ500 in a place where enough water pressure is applied. Therefore, it is recommended that the LQ500 be installed as far away as possible from the pipe outlet opened to atmosphere. This is to preve ...

  • Toshiba Density (Consistency) Meter LQ500 - page 7

    LQ500 7 L1 L2 Tx+ TX- Rx+ Rx- SG FG +24V 0V FG Ec+ Ec- FG Tx+ Tx- Rx+ Rx- SG FG +24V 0V FG Communication cable Power su pply cable Converter Power su pp l y 100 to 240 V ac , 50/60Hz Ground terminal (PE) (Ground re sistan ce 100 ohm or less ) Densi ty ( cons ist en cy) mea surem ent outp ut (4-20mAdc, 750 ohm max ., isolated out put) Density mult i ...

  • Toshiba Density (Consistency) Meter LQ500 - page 8

    LQ500 No. EJL-106A Ordering Information When ordering the LQ500, refer to Table 4. Type Specification Code. An entry must be made for each of the columns. The following items must also be specified: 1. Fluid characteristics: • Type of material to be measured • Density (consistency) (max., normal, min.) • Temperature (max., normal, min.) • P ...

  • Toshiba Density (Consistency) Meter LQ500 - page 9

    LQ500 9 Table 4. Type Specification Code (LQ500 Density (consistency) Meter) TYPE CAT Code SPECIF ICATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 L Q 5 0 0 Microwave Density (Consistency) Meter A S t a n d a r d M e t e r S i z e 0 5 5 0 m m ( 2 " ) 0 8 8 0 m m ( 3 " ) 1 0 1 0 0 m m ( 4 " ) 1 5 1 5 0 m m ( 6 " ) 2 0 2 0 0 m m ( 8 " ...

メーカー Toshiba カテゴリー Power Supply

Toshiba Density (Consistency) Meter LQ500のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Density (Consistency) Meter LQ500の取扱説明書
- Toshibaの製品カード
- パンフレット
- またはToshiba Density (Consistency) Meter LQ500の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Toshiba Density (Consistency) Meter LQ500の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Toshiba Density (Consistency) Meter LQ500の取り付け説明書、サービスマニュアル、簡易説明書、またはToshiba Density (Consistency) Meter LQ500のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Toshiba Density (Consistency) Meter LQ500の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Toshiba Density (Consistency) Meter LQ500デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがToshiba Density (Consistency) Meter LQ500を使用するのを助ける技術的文書のことです。説明書は通常、全てのToshiba Density (Consistency) Meter LQ500ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Toshibaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Toshiba Density (Consistency) Meter LQ500の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははToshiba Density (Consistency) Meter LQ500の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Toshiba Density (Consistency) Meter LQ500に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Toshiba Density (Consistency) Meter LQ500デバイスの基本機能を使うにあたってのヒント。 Toshiba Density (Consistency) Meter LQ500のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Toshiba Density (Consistency) Meter LQ500に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるToshiba Density (Consistency) Meter LQ500のメーカー/サービスへの連絡先に関する情報。

Toshiba Density (Consistency) Meter LQ500についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもToshiba Density (Consistency) Meter LQ500の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがToshiba Density (Consistency) Meter LQ500で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)