Bloomfield 2212の取扱説明書

26ページ 3.11 mb
ダウンロード

ページに移動 of 26

Summary
  • Bloomfield 2212 - page 1

    BLOO MFIEL D IND USTRI ES 2 ERIK CIRCLE, P .O .Box 280 V erd i, NV 89439 U.S.A. Custom er Service (775) 345- 0444 Ex t.502 fax ( 775) 34 5-0569 ww w .w el ls bl oom fi el d. co m OWNERS MANU AL LX DECANTER BREWER MODELS 2212 2216 2216EX 2272 2274EX Includes INSTALLAT ION OPERAT ION USE & CARE SERVICE p/n 74733 Rev. D M656 05 0208 cps 656 Model ...

  • Bloomfield 2212 - page 2

    All electrical equipment ma nufactured by BLOOMFIELD INDUSTRI ES is w arranted against d efects in m aterials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefi t of the original purchaser, except that: a. ai ...

  • Bloomfield 2212 - page 3

    ELECTRICAL SPECIFIC A TIONS* MODEL WAT TS VOLTS 1ø Hz CIRCUIT REQUIRED WIRE 2212 1800 120 50/60 15 AMP ( NEMA 5-15R ) 2 + ground 2216 3500 120/240 50/60 HARD WIRE TO CIRCUIT BREAKER 3 + ground 2272 1800 120 50/60 15 AMP ( NEMA 5-15R ) 2 + ground 2216EX 3500 240 50/60 HARD WIRE TO CIRCUIT BREAKER 2 + ground 2274EX 3500 240 50/60 HARD WIRE TO CIRCUI ...

  • Bloomfield 2212 - page 4

    FEATURES & OPERATING CONTROLS 1. Brew Indicator Glows during brew cycle, flas hes in “Brew W ait” 2. Heat Indicator Glows when heating elem ents are energized 3. Power Indicator Glows when power is on 4. Warmer Indicators Glow when individual warmers are turned on 5. Brew Key Press to initiate bre w cycle 6. Cancel Key Press to terminate br ...

  • Bloomfield 2212 - page 5

    PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels w hich require the use of tools. Failure to heed this w arning c an resu lt in electrical shock . WA RNING : Injury Hazar d All installation pr ...

  • Bloomfield 2212 - page 6

    INSTALLATION INSTRUCTIONS RE A D THIS C A R EFULL Y BEFORE ST ARTING THE INST A LL A TION REFER TO EXPLODED VIEWS PAGES 16 thru 19 FOR COMPONENT NAMES/NUMBERS 1. Unpack the unit. Inspec t a ll components for comp leteness and condition. Ensure that all packing materials have been removed from the unit. 2. (See page 13.) Remove the Top W armer Unit ...

  • Bloomfield 2212 - page 7

    INSTALLATION INSTRUCTIONS (contin ued) NOTE: This equipment must be installed to comply with applica- ble f ederal, state and local codes and ordin a nc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground. Electrical shock will cause death or ...

  • Bloomfield 2212 - page 8

    OPERATION To over-ride th e Br ew Wait mode , press and hold the BR E W key for 3 second s when the brewer is in Brew Wait mode (i.e. when brew light is flashing). The brew will proceed immediatel y regardless of water temper ature. This f eature should onl y be used whe n testing water volume, otherwise the br ew will proceed with the water below ...

  • Bloomfield 2212 - page 9

    OPERATION (continued) WA R NI NG : Burn H azard. This applianc e dispenses very hot liquid. Serious bodily injury from scalding can occ ur from contact wi th dispensed liquids. CAUTION: Burn Hazard To avoid splashing or overflowing hot liqu ids, ALWAYS use an empty decanter before starting the brew cycle . Failure to comply can cause serio us burns ...

  • Bloomfield 2212 - page 10

    CLEANING INSTRUCTIONS CA UTI ON: Burn Hazard Brewing an d serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CA UTIO N: Electric Shoc k Hazard Do not submerge or i mmerse brewer in wat er. Do not pour or splash water into o r over air vents, control panel or warmer plates. IMPORTANT: DO NOT use steel wool, s ...

  • Bloomfield 2212 - page 11

    A. Adjust Brew Time B. Adjust Brew Temperature C. Adjust Quality Timer D. Adjust Dripout Timer E. Adjust After Hours Timer AB CD E UNDE R TOP COVER (IN SECO NDS) BREW TIME R (IN °F) BREW TEMP (I N 5 MIN I NCR) QUALI TY TIM ER (IN SECONDS) DRIPOU T TIMER (IN ONE HR INCR) AFTER HOU RS T IMER WA TE R LEVEL PROBE TEMP PROBE 20 185 6 OFF 3 60 90 30 70 ...

  • Bloomfield 2212 - page 12

    SERVICING INSTRUCTIONS — ELECTRICAL OPERATION SEE PAGE 11 FOR COMPONENT NAMES / NUMBERS 1. Pressing the PO W ER key energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Automatic fill is acco mplished via a FILL SOLENOID (32) and a W ATER LEVEL PROBE (7). The probe senses ground through the water in the tank. When the water le ...

  • Bloomfield 2212 - page 13

    27 28 WARM ER MOUN TI NG 3 5 4 20 32 18 7 8 15 17 4 E-MA XLX ELECT RICAL COMPONENT 12 0V UNITS 12 0/2 40V UNITS SERVICING INSTRUCTIONS — ELECTRICAL 3 PROBE, TEMPERATURE (THERMISTOR) 4 THERMOSTAT, HI-LIMIT 5 GROMMET 7 PROBE, WATER LEVEL 8 SLEEVE, WATER LE VEL PROBE 15 ELEMENT, W ATER HEATING 17 ASSEMBLY, TRIAC & HEAT SINK 18 BREW SOLENOID 2 ...

  • Bloomfield 2212 - page 14

    OPERATION SEE PAGE 13 FOR COMPONENT NAMES/NUMBERS 1. W ater enters at the inlet fi tting of the fill solenoid (32). The solenoid adm its water via a command from the controller. N OTE: The soleno id has an inter nal strainer. To clean the strainer: Shut off water supply. Unscrew the plastic cap protruding from the rear of the brewer. Remove the c a ...

  • Bloomfield 2212 - page 15

    SERVICING INSTRUCTIONS — PLUMBING 13 ITEM DESCRI PTION P ART N0. U SED ON 1 2 ASS E MBL Y , W A TER T ANK (120 V) 83500 2212, 22 72 6 GA SKE T , T AN K L ID 83 499 AL L 9 T ANK L ID 83 504 ALL 10 RET AINING CLIP , T ANK LID 83506 ALL 1 1 HOS E, OV ERFL O W (2 pc SILIC O NE 4.5” LO NG) 86014 ALL 12 HOSE , F AUCE T SUPPL Y (SIL ICONE, 10” LONG) ...

  • Bloomfield 2212 - page 16

    SERVICING INST RUCTIONS — DE-LIMING HEA TER TANK 1. Disconnect br ewer form the electrical sup pl y. Turn off the water suppl y and disc onnect water suppl y from the brewer inlet fitting. 2. Remove the top panel or top wa rmer section to gain access to internal components. 3. Disconnect water level sensor and w ater te mperature sensor from the ...

  • Bloomfield 2212 - page 17

    SERVICING INSTRUCTIO NS — DIAGNOSTICS & TROUBLESHOOTIN G) If the E-Max™ LX goes into an error mode as outlined below , it will probably be necessary to reset the bre w er in order to test individual components. Note the reset proce dure below : * FOR “LOW W ATER” OR “OVERHEAT” ERRORS: PRESS & HOLD CANCEL FOR 3 SECONDS, OR RE-ENE ...

  • Bloomfield 2212 - page 18

    EXPLODED VIEW — IN-LINE MODELS 16 ...

  • Bloomfield 2212 - page 19

    PARTS LIST — IN-LIN E MODELS 17 ...

  • Bloomfield 2212 - page 20

    EXPLODED VIEW — STEP-UP MODELS 18 ...

  • Bloomfield 2212 - page 21

    PA RTS LIST — STEP -UP M ODE L S 19 ...

  • Bloomfield 2212 - page 22

    WIRING DIAGRAM — IN-LINE MOD ELS 20 ...

  • Bloomfield 2212 - page 23

    WIRING DIAGRAM — I N-LINE EXPORT MODEL 21 ...

  • Bloomfield 2212 - page 24

    CONTROL BOARD 1 WP3 2 WP2 3 WP1 1 Heat er ( Line ) 2 Inlet ( Line) 3 Dump Line 4 Power (Line) 5 6 Dump (Neut) 7 Power (Neut) 8 Heater (Neut) Lin e Load Ga te Fr ont Wa rm er P late #2 120V 100 Watt Main Warme r P late 12 0V 100 Watt Rear War mer Pl ate #3 12 0V 100 Watt Out let Va l v e In let Va l v e 120 Volt 15 00 Wat t Ta n k H e a t e r Hi- Li ...

  • Bloomfield 2212 - page 25

    WIRING DIAGRAM — STEP-UP EXPORT MODEL 23 ...

  • Bloomfield 2212 - page 26

    Blo omfi eld Ind ustries , In c. Divis ion of Carri er Refrige r atio n In U S In C an ada PO Box 28 0, V e rdi, NV 89439 T el ephone: 775- 345-0444 Servi ce: 88 8-492-2782 Fax: 888-792-278 3 websit e: www . wellsbl oomfi eld.com T el ephone: 877- 507-1700 Servi ce: 90 5-507-1700 Fax: 905-507-1777 website: www .bl oomcan.com Bloomfi eld I ndustr ie ...

メーカー Bloomfield カテゴリー Coffeemaker

Bloomfield 2212のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 2212の取扱説明書
- Bloomfieldの製品カード
- パンフレット
- またはBloomfield 2212の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bloomfield 2212の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bloomfield 2212の取り付け説明書、サービスマニュアル、簡易説明書、またはBloomfield 2212のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bloomfield 2212の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bloomfield 2212デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBloomfield 2212を使用するのを助ける技術的文書のことです。説明書は通常、全てのBloomfield 2212ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bloomfieldの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bloomfield 2212の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBloomfield 2212の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bloomfield 2212に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bloomfield 2212デバイスの基本機能を使うにあたってのヒント。 Bloomfield 2212のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bloomfield 2212に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBloomfield 2212のメーカー/サービスへの連絡先に関する情報。

Bloomfield 2212についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBloomfield 2212の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBloomfield 2212で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)