Linear AE1000Plusの取扱説明書

24ページ 1.28 mb
ダウンロード

ページに移動 of 24

Summary
  • Linear AE1000Plus - page 1

    USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - T oll Free FAX (800) 468-1340 www .linearcorp.com AE1000Plus T elephone Entr y & Access Control System PRINTER’S INSTRUCTIONS: INSTR,INSTL,AE1000PLUS - LINEAR P/N: 227522 B - INK: BLACK - MA TERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM ...

  • Linear AE1000Plus - page 2

    2 Contents Introduction The Model AE1000Plus T elephone Entr y & Access Control System is designed for use as a primary access control device f or gated communities, parking garages, offi ce b uildings, apartments, dor mitories, hotels/motels, commercial b uildings and recreational facilities. Housed in a lock ed, rugged stainless steel faced ...

  • Linear AE1000Plus - page 3

    3 Har dwar e F eatur es ✓ BUILT -IN RADIO RECEIVER Variable gain, high-sensitivity receiver for wireless transmitters ✓ FOUR FORM “C” (N.O. & N.C) RELAYS Each relay has 3-amp @ 24-volt rating ✓ FOUR REQUEST-TO-EXIT INPUTS Activates access device for exiting using a hardwired switch ✓ FOUR SENSING INPUTS For sensing door position to ...

  • Linear AE1000Plus - page 4

    4 Accessor y Over view PBUS Accessories Sev eral compatib le accessories are availab le to connect to the three 6-wire communications “PBUS” inputs. Up to six PBUS accessor ies can be used with each AE1000Plus unit. AM-RRR R emote Radio R ecei ver For wireless tr ansmitters, connect the Model AM-RRR high-gain superheterodyne UHF receiver . The ...

  • Linear AE1000Plus - page 5

    5 Component Locations OPTIONAL CAME R A DI S PLAY CA B INET LOCK OPTIONAL PO S TAL LOCK S PEAKE R KEYPAD LI G HTIN G KEYPAD MIC R OPHONE EA R TH GR OUND S TUD POWE R TE R MINAL S R ELAY TE R MINAL S WIE G AND INPUT TE R MINAL S TELEPHONE TE R MINAL S TELEPHONE JACK TAMPE R S WITCH MAIN POWE R S WITCH R ECEIVE R R AN G E KNO B ANTENNA CONNECTO R MIC ...

  • Linear AE1000Plus - page 6

    6 Wiring Diagram AE1000Plus THIS WIRING EXAMPLE SHOWS: DOOR ACCESS WITH A DOOR STRIKE ON RELAY CHANNEL "A" DOOR ACCESS WITH A MAGNETIC LOCK ON RELAY CHANNEL "B" GATE ACCESS WITH A GATE OPERA TOR ON RELAY CHANNEL "C" (YOUR INSTALLATION MAY VARY) G ND DAT 0 DAT 1 LED1 HOLD PW R LED 2 G ND DAT 0 DAT 1 LED1 HOLD PW R LED 2 ...

  • Linear AE1000Plus - page 7

    7 Impor tant Mounting Requir ements The AE1000Plus T elephone Entr y System can be installed for pub lic or private use. The mounting requirements will vary depending on the installation. Review the f ollowing inf ormation before beginning the installation. Mounting Environment Consider the environmental f actors at the desired mounting location. T ...

  • Linear AE1000Plus - page 8

    8 Entr y Sys tem Mounting The AE1000Plus cabinet is designed to be mounted three wa ys: • The unit can be mounted directly to a wall or fl at surf ace. • The unit can be mounted recessed into the wall. • The unit can be mounted on a standard gooseneck pedestal. Choose a well lit location near the controlled opening. Wiring access f or power ...

  • Linear AE1000Plus - page 9

    9 Entr y Sys tem Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessor y trim-ring (P/N ACP00909). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring. 1. Identify the location of any studs in the wall. 2. Cut a 16-1/4” high by 13-1/4” wide rectangular hole between studs at the moun ...

  • Linear AE1000Plus - page 10

    10 Rela y Output Wiring Any of the f our relay outputs channels (A-D) can be used to control access devices on doors or gates . Door or Pedestrian Gate Control 1. Install a low v oltage electric door str ike or magnetic lock as a locking de vice for the door or pedestrian gate. 2. Install the power supply or tr ansformer for the loc king device. DO ...

  • Linear AE1000Plus - page 11

    11 P ower, Bat ter y, & Gr ound Wiring Power Wiring ✦ NO TE: DO NO T APPL Y PO WE R UNTIL THE IN S T ALLA TION I S COMPLETE. TU R N MA S TE R PO WE R S WITCH OFF B EFO R E WI R IN G . 1. Route two wires between the AE1000Plus and the pow er transf or mer . • For po wer wire runs up to 100 feet, use 18 A WG, THHN 600-v olt insulated wire. ? ...

  • Linear AE1000Plus - page 12

    12 T elephone Wiring For telephone entry and programming, the AE1000Plus connects to a standard telephone line. Impor tant T elephone Wiring Tips • DO NO T ROUTE TELEPHONE AND AC WIRIN G INSIDE THE SAME CONDUIT . Route all telephone wires inside a dedicated conduit that is at least six inches aw ay from any A C line wiring. • All telephone wiri ...

  • Linear AE1000Plus - page 13

    13 Optional Color CC T V Camera Linear’ s Model CCM-1 (P/N A CP00904) CCTV camera can be installed inside the AE1000Plus Entr y System. The camera pro vides a video signal for vie wing the area in front of the entry system. The CAMERA connector is used to connect the camera to the AE1000Plus. The 4-conductor cable routes power to , and video from ...

  • Linear AE1000Plus - page 14

    14 PBUS Accessories Up to six accessories (keypads , proximity readers , remote receivers) can be connected to the three PBUS input/output por ts. A typical application for a remote k eypad would be to control a second door or gate . Linear’ s PBUS de vices compatible with the AE1000Plus are: • AM-RRR Remote Radio Receiver • AM-RGR Remote Rad ...

  • Linear AE1000Plus - page 15

    15 Optional Net w ork Connection Linear’ s AE1000Plus, AE2000Plus, & AM3Plus Access Control Systems can be connected together in a network. A network will allow sharing programming and user inf ormation between the systems. Program each unit to a different netw ork Node Address (see Page 19). ✦ IMPORT ANT COMP A TIBILITY NO TE: Linear’ s ...

  • Linear AE1000Plus - page 16

    16 Optional Net w ork Connections (Continued) Network Confi guration for AccessBase2000 Programming If the system is going to be programmed using Linear’ s AccessBase2000 software, units comm unicate with each other on the network through RS-485 cable connections . AccessBase2000 does not suppor t unit-to-unit network communications through mode ...

  • Linear AE1000Plus - page 17

    17 NET-A G ND NET- B NETWO R K UNIT "3" NET-A G ND NET- B NETWO R K UNIT "4" NET-A G ND NET- B NETWO R K MA S TE R UNIT "1" NET-A G ND NET- B NETWO R K UNIT "2" ACCE SS CONT R OL HOME R UN NETWO R K U S ING ONE UNIT A S A NETWO R K MA S TE R NOTE : GROUND CABLE SHIELDS ONLY AT ONE END S HIELD S HIELD S HIELD ...

  • Linear AE1000Plus - page 18

    18 Sys tem A d jus tments The factory settings are suffi cient f or most installations. The system can be adjusted to customize the installation. Speaker V olume Adjustment If the resident’ s voice from the speak er is too loud or not loud enough, the speaker’ s volume can be adjusted. 1. Locate the SPEAKER V OLUME adjustment on the CPU circui ...

  • Linear AE1000Plus - page 19

    19 Internal Contr ols On-board Pushbuttons Sev en pushbuttons are on the main circuit board. Refer to the fi gure for the location of each pushbutton. • UP button adds one to the value on the ST A TUS/PROGRAM displa y . • DOWN b utton subtracts one from value on the ST A TUS/PROGRAM displa y . Press with the UP button f or one second to enter ...

  • Linear AE1000Plus - page 20

    20 AE1 000Plus Operation Requesting Access with an Entr y Code • Residents hav e up to 40 seconds to ke y in their entr y code. • Up to eight seconds are allow ed between each keystrok e. • All digits of the entry code must be entered. Example: If the entr y code length is set for f our digits, and the code is 0042, the user must enter “0 0 ...

  • Linear AE1000Plus - page 21

    21 Dimension Drawing 15-1/8" 18-3/8" 2-5/8" OPTIONAL TRIM RING 13" 16-1/4" 3-1/2" AE1000PLUS Specifi cations MECHANICAL Case dimensions: 13” W x 16-1/4” H x 3-1/2” D ELECTRICAL V oltage: 16-24 V olts AC or 12-24 V olts DC Current: 1500 mA @ 16 V AC maximum Backup Battery: Externally charged 12 V olt DC source Ou ...

  • Linear AE1000Plus - page 22

    22 T r oubleshooting System completely dead 1. No power from tr ansformer . Check v oltage at transf or mer terminals. 2. Check v oltage at AE1000Plus power terminal strip. Buzz on speaker 1. Check f or 24 volt A C power shorted to wiring conduit. 2. Check f or telephone line shor ted to ground. 3. V erify that telephone wires are twisted pair. 4. ...

  • Linear AE1000Plus - page 23

    23 Linear Limited W ar rant y This Linear product is warranted against def ects in material and workmanship for tw enty-four (24) months. This warranty e xtends only to wholesale customers who buy direct from Linear or through Linear’ s normal distr ibution channels. Linear does not warrant this product to consumers. Consumers should inquire from ...

  • Linear AE1000Plus - page 24

    Copyright © 2008 Linear LLC 227522 B ...

メーカー Linear カテゴリー Home Security System

Linear AE1000Plusのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AE1000Plusの取扱説明書
- Linearの製品カード
- パンフレット
- またはLinear AE1000Plusの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Linear AE1000Plusの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Linear AE1000Plusの取り付け説明書、サービスマニュアル、簡易説明書、またはLinear AE1000Plusのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Linear AE1000Plusの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Linear AE1000Plusデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLinear AE1000Plusを使用するのを助ける技術的文書のことです。説明書は通常、全てのLinear AE1000Plusユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Linearの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Linear AE1000Plusの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLinear AE1000Plusの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Linear AE1000Plusに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Linear AE1000Plusデバイスの基本機能を使うにあたってのヒント。 Linear AE1000Plusのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Linear AE1000Plusに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLinear AE1000Plusのメーカー/サービスへの連絡先に関する情報。

Linear AE1000Plusについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLinear AE1000Plusの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLinear AE1000Plusで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください