Master Lock 150000 BTU/Hrの取扱説明書

24ページ 0.41 mb
ダウンロード

ページに移動 of 24

Summary
  • Master Lock 150000 BTU/Hr - page 1

    Heater Sizes: 70,000 100,000 150,000 BTU/Hr IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. 100 SIDE PV 002 PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL R 150 SIDE HANDLE PFA/PV 005 ...

  • Master Lock 150000 BTU/Hr - page 2

    2 101585 Safety Information ......................................................................... 3 Product Identification .................................................................... 4 Unpacking ...................................................................................... 5 Assembly ........................................... ...

  • Master Lock 150000 BTU/Hr - page 3

    3 101585 SAFETY INFORMA TION ! DANGER Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the fl u, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected b ...

  • Master Lock 150000 BTU/Hr - page 4

    4 101585 Upper Shell Figure 3 - 150,000 BTU/Hr Model 35/50/70,000 BTU/HR DOMESTIC PFA/PV 042 Handle Fuel Cap Lower Shell Side Cover Fuel Tank Figure 1 - 70,000 BTU/Hr Model Side Cover Fuel Tank Lower Shell Fuel Cap Fan Guard Power Cord Upper Shell PRODUCT IDENTIFICA TION Upper Shell Hot Air Outlet Hot Air Outlet Air Filter End Cover Fan Guard Power ...

  • Master Lock 150000 BTU/Hr - page 5

    5 101585 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y (For 100,000 and 150,000 BTU/Hr Models Only) These models are furnished with wheels and handles. Wheels, handles, and ...

  • Master Lock 150000 BTU/Hr - page 6

    6 101585 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fi ne mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the combustion cham ...

  • Master Lock 150000 BTU/Hr - page 7

    7 101585 VENTILA TION OPERA TION Continued Figure 6 - Flame-Out Control Reset Button, 70,000 BTU/Hr Model Figure 7 - Flame-Out Control Reset Button, 100/150,000 BTU/Hr Models W ARNING Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide ...

  • Master Lock 150000 BTU/Hr - page 8

    8 101585 OPERA TION Continued To Stop Heater 1. Unplug power cord from outlet. To Restart Heater 1. Wait 2 minutes after stopping heater. 2. Repeat steps under To Start Heater , page 7. 1. Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, dra ...

  • Master Lock 150000 BTU/Hr - page 9

    9 101585 TROUBLE- SHOOTING OBSERVED FAULT POSSIBLE CAUSE REMEDY Wrong pump pressure Dirty air output, air intake, and lint fi lters Dirty fuel fi lter Dirt in nozzle Dirty photocell lens Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time See Pump Pressure Adjustment , page 12. See Air Output, ...

  • Master Lock 150000 BTU/Hr - page 10

    10 101585 SER VICE PROCEDURES Upper Shell Removal 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. 2. Lift upper shell off. 3. Remove fan guard. Figure 10 - Fuel Filter Removal, 70,000 BTU/Hr Model Fuel Filter Side Cover Fuel Line Fuel Filter (70,000 BTU/Hr Model) 1. Remove ...

  • Master Lock 150000 BTU/Hr - page 11

    11 101585 150,000 BTU/Hr PFA/P 041.G Fuel Filter (100/150,000 BTU/Hr Models) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel fi lter neck. 4. Carefully pry bushing, lower fuel line, and fuel fi lter out of fuel tank. 5. Wash fuel fi lter with clean fuel and replace in tank. 6. Attac ...

  • Master Lock 150000 BTU/Hr - page 12

    12 101585 Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover. 4. Replace air output and lint fi lters. 5. Wash or replace air intake fi lter (see Preventative Maintenance Schedule, page 8). 6. Replace fi lter end cover. 7. Re ...

  • Master Lock 150000 BTU/Hr - page 13

    13 101585 Nozzle 1. Remove upper shell (see page 10). 2. Remove fan (see page 15). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using 5/16" nut-driver and remove burner head from combustion chamber. ...

  • Master Lock 150000 BTU/Hr - page 14

    14 101585 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover and air fi lters. 4. Remove pump plate screws using 5/16" nut- driver. 5. Remove pump plate. 6. Remove rotor, insert, and blades. 7. Check for debris in pump. ...

  • Master Lock 150000 BTU/Hr - page 15

    15 101585 Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 10). 2. Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft. 3. Slip fan off motor shaft. 4. Clean fan using a soft cloth moistened wi ...

  • Master Lock 150000 BTU/Hr - page 16

    16 101585 ILLUSTRA TED P ARTS BREAKDOWN 70,000 BTU/Hr 18-2 Motor and Pump Assembly 18-5 18-16 18-4 18-8 18-3 18-6 18-7 18-9 18-10 18-11 18-12 18-13 18-14 18-15 10-2 10-3 10-4 10-5 10-6 10-7 10-1 18-1 18-18 Burner Head Assembly 1 2 4 3 5 6 7 8 10 11 12 12 14 15 16 17 20 18 19 21 22 24 25 26 27 28 29 30 31 32 34 38 37 41 13 9 33 35 36 42 43 39 40 23 ...

  • Master Lock 150000 BTU/Hr - page 17

    17 101585 P ARTS LIST 70,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-54 Upper Shell 1 3 100647 ...

  • Master Lock 150000 BTU/Hr - page 18

    18 101585 ILLUSTRA TED P ARTS BREAKDOWN 100,000 BTU/Hr 13-1 13-2 13-3 13-4 13-5 13-7 13-8 13-9 13-10 13-11 13-12 13-13 13-15 13-16 13-17 13-18 13-14 Motor and Pump Assembly BURNER HEAD 100 EAI/EBI PFA/P 022 8-2 8-6 8-5 8-4 8-3 8-1 Burner Head Assembly 8-7 13-6 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 25 29 30 31 32 33 34 35 36 37 38 39 40 4 ...

  • Master Lock 150000 BTU/Hr - page 19

    19 101585 P ARTS LIST 100,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. **Not available as an assembly, order parts separately. KEY PART PART NO. NUMBER DESCRIPTION QTY ...

  • Master Lock 150000 BTU/Hr - page 20

    20 101585 ILLUSTRA TED P ARTS BREAKDOWN 150,000 BTU/Hr 10-2 10-11 Motor and Pump Assembly 10-1 10-4 10-3 10-5 10-6 10-7 10-8 10-9 10-10 10-12 10-13 10-14 10-15 10-16 10-17 10-18 BURNER HEAD 100 EAI/EBI PFA/P 022 Burner Head Assembly 7-1 7-2 7-3 7-4 7-5 7-7 7-6 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 25 26 27 24 28 29 20 22 21 30 31 41 33 34 35 36 13 ...

  • Master Lock 150000 BTU/Hr - page 21

    21 101585 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 150,000 BTU/Hr 1 098511-138 Upper Shell 1 2 100647-01 Screw, #10-16 x 1/2" 8 3 098512-29 Combustion Chambe ...

  • Master Lock 150000 BTU/Hr - page 22

    22 101585 4 7 KEY PART PART 100,000 150,000 NO. NUMBER DESCRIPTION QTY. QTY. 1 HA2203 Handles 2 — HA2204 Handles — 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 8 3 M12342-3 Wheel Support Frame 1 — M12831-3 Wheel Support Frame — 1 4 NTC-3C Hex Nut, #10-24 8 8 5 097896-01 Wheel 2 2 6 M28526 Cap Nut 2 2 7 M51015-01 Axle 1 — M16801-2 Axle — ...

  • Master Lock 150000 BTU/Hr - page 23

    23 101585 WIRING DIAGRAMS Figure 26 - Wiring Diagram ACCESSORIES Purchase accessories from your local dealer. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. For 70,000 BTU/Hr model only. AIR GAUGE KIT - HA1180 For all models. Special tool to check pump pressure. Ignitor Wh ...

  • Master Lock 150000 BTU/Hr - page 24

    W ARRANTY AND REP AIR SER VICE POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. Any transportation charges, costs of installation, duty, taxes or any other charges whatsoever must be borne by the user. DESA International's oblig ...

メーカー Master Lock カテゴリー Electric Heater

Master Lock 150000 BTU/Hrのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 150000 BTU/Hrの取扱説明書
- Master Lockの製品カード
- パンフレット
- またはMaster Lock 150000 BTU/Hrの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Master Lock 150000 BTU/Hrの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Master Lock 150000 BTU/Hrの取り付け説明書、サービスマニュアル、簡易説明書、またはMaster Lock 150000 BTU/Hrのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Master Lock 150000 BTU/Hrの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Master Lock 150000 BTU/Hrデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMaster Lock 150000 BTU/Hrを使用するのを助ける技術的文書のことです。説明書は通常、全てのMaster Lock 150000 BTU/Hrユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Master Lockの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Master Lock 150000 BTU/Hrの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMaster Lock 150000 BTU/Hrの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Master Lock 150000 BTU/Hrに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Master Lock 150000 BTU/Hrデバイスの基本機能を使うにあたってのヒント。 Master Lock 150000 BTU/Hrのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Master Lock 150000 BTU/Hrに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMaster Lock 150000 BTU/Hrのメーカー/サービスへの連絡先に関する情報。

Master Lock 150000 BTU/Hrについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMaster Lock 150000 BTU/Hrの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMaster Lock 150000 BTU/Hrで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)