Liebert Network Cardの取扱説明書

32ページ 1.1 mb
ダウンロード

ページに移動 of 32

Summary
  • Liebert Network Card - page 1

    User Manual English OpenComms Web Card ...

  • Liebert Network Card - page 2

    CONTENTS ABOUT THIS USER MANUAL QUICK START GUIDE INTRODUCTION INSTALLATION Installing the Card Connecting the Card to the Network Configuring the Card SERVICE TERMINAL Opening a Service Terminal Connection Main Menu System Information Menu Network Interface Menu SNMP Communication Menu Web Server Menu Firmware Updates Menu Factory Settings Menu WE ...

  • Liebert Network Card - page 3

    ABOUT THIS USER MANUAL Welcome to the User Manual for the OpenComms Web Card. This man- ual is available from Liebert's web site at www.liebert.com. The most recent version is always located online and you should consult the Web if you feel you have an older copy. ABOUT THE QUICK START GUIDE On the next two pages you will find a copy of the Qu ...

  • Liebert Network Card - page 4

    CONFIGURE ! Using a terminal emulation software package, like HyperT erminal™, open a direct connection to the card. BAUD RATE: 9600 DAT A BITS: 8 PARITY : None STOP BITS: 1 FLOW CONTROL: None ! Press “ENTER” for the Main Menu. ! Select option “2” and follow the instructions to enter an IP ADDRESS, NETMASK, and GATEWA Y . ! Return to the ...

  • Liebert Network Card - page 5

    Worldwide Support Worldwide FAX Support U.S.A. U.K. France Germany Italy Netherlands E-mail Web site +1 614-841-6755 +1 614-841-6755 1-800 222-5877 +44 (0) 1628 403200 +33 (0) 1 43 60 01 77 +49 89 99 19 220 +39 02 98250 324 +31 (0) 475 503333 monitoring@liebert.com www.liebert.com User Manual This Quick Start Guide is designed to give you all of th ...

  • Liebert Network Card - page 6

    Installing the Card The OpenComms Web Card is hot swappable and user-serviceable. Although you do not need to turn off the UPS, disconnect any loads, or restart the UPS to install or remove the card, discretion should be used. CAUTION: The Intellislot Bay is located in close proximity to the UPS' output and the UPS' electrical receptacles ...

  • Liebert Network Card - page 7

    Opening a Service Terminal Connection This section covers the Service Terminal in detail. From the Service Ter- minal, you can configure all settings of the card. NOTE: You can also configure many of the setting discussed in this sec- tion from the Web. To specify that the card communicate at either 10Mbit or 100Mbit instead of it trying to auto-ne ...

  • Liebert Network Card - page 8

    5. Press "Enter" to see the Main Menu. If you do not see the Main Menu, press "Enter" again several times. If the Main Menu fails to appear, confirm that the blue configuration cable is installed properly, that your PC or terminal COM port is active, and that you are using the correct communication settings. If, after verifying ...

  • Liebert Network Card - page 9

    Selecting Option "1" from the Main Menu opens the System Information Menu. Liebert Network Interface Card System Information Menu ------------------------ 1: Name Data Room UPS 2: Contact Network Services x100 3: Location Building 2, Floor 4 4: Description Supporting Main Server <ESC>: Cancel menu level Please select a key ?> The ...

  • Liebert Network Card - page 10

    Network Interface Menu Selecting Option "2" from the Main Menu opens the Network Interface Menu. Network Interface Menu ----------------------- 1: Speed/Duplex Auto 2: Boot mode DHCP IP Address 0.0.0.0 Netmask 0.0.0.0 <ESC>: Cancel menu level Please select a key ?> From the Network Interface Menu you can configure the Network set ...

  • Liebert Network Card - page 11

    Select option "2" to change Boot mode settings of the card. Valid Selections: ------------------ 1. Static 2. BootP 3. DHCP Select Boot Mode: Your Boot mode setting options are Static, BootP, and DHCP. The card ships from the factory with DHCP service enabled. DHCP allows the card to obtain an address dynamically from a DHCP server on you ...

  • Liebert Network Card - page 12

    SNMP Communication Menu Liebert Network Interface Card SNMP Communications Menu ------------------------- 1: Authentication Traps 'no' 2: Display/Modify Communities 3: Display/Modify Trap Communities <ESC>: Cancel menu level Please select a key ?> Selecting Option "3" from the Main Menu opens the SNMP Communica- tions M ...

  • Liebert Network Card - page 13

    The options "a" "d" and "e" allow you to manage your list of network devices with access to the card. These options can be used as a com- plex instruction to add a single device, specify read/write access rights, and designate the Community String. For, example, entering: "a 126.4.1.200 read NewCommunity" add ...

  • Liebert Network Card - page 14

    The options "a" "d" and "e" allow you to manage you list of network devices that will receive SNMP Traps from the card. These options can be used as a complex instruction to add a single device and designate the Community String. For, example, entering: "a 126.4.1.200 NewCommunity" adds device 126.4.1.200 to ...

  • Liebert Network Card - page 15

    Web Server Menu Web Server Menu ---------------- 1: Web Server 'enabled' 2: Change Username/Password <ESC>: Cancel menu level Please select a key ?> Selecting Option "4" from the Main Menu opens the Web Server Menu. From the Web Server Menu you can enable/disable the Web functionality of the card and edit the Username/P ...

  • Liebert Network Card - page 16

    Firmware Updates Menu Firmware Updates Menu ---------------------- 1: Initiate XMODEM session... <ESC>: Cancel menu level Please select a key ?> Selecting Option "5" from the Main Menu opens the Firmware Updates Menu. From the Firmware Updates Menu you can reload the firmware of the card. Please consult the instructions you downl ...

  • Liebert Network Card - page 17

    Factory Settings Menu Factory Settings Menu ---------------------- 1: Reset to Factory Defaults Manufacture Date OCT 27,2000 MAC Address 00-00-68-16-00-03 Serial Number 415981G101D2000OCT270003 <ESC>: Cancel menu level Please select a key ?> Selecting Option "6" from the Main Menu opens Factory Settings Menu. The Factory Settings ...

  • Liebert Network Card - page 18

    Opening a Web Connection This section explains the Web interface in detail. From the Web, you can monitor and control the UPS in which the card is installed. You can also configure many settings of the card. NOTE: To specify that the card communicates at either 10Mbit or 100Mbit, instead of it trying to auto-negotiate, you must use the Service Term ...

  • Liebert Network Card - page 19

    You will notice that information on the Web page is grouped in Tabs and Folders. The card organizes similar information together in folders, and similar functions in tabs. Tabs: Across the top of the screen are four tabs, monitor, control, config- ure, and support. As the tab names suggest, different information is pre- sented and different operati ...

  • Liebert Network Card - page 20

    Connected Device Information Clicking between the monitor, contol, configure, and support tabs gives you access to folder lists on the bottom of the left pane. Although the folder list changes, depending on the tab selected, the top portion of the left pane remains constant. In the top or the left pane, connected device information and connected UP ...

  • Liebert Network Card - page 21

    Security By opening a connection to the OpenComms Web Card, you are able to do three things. You can Monitor, Configure and Control the UPS. The card allows any user with access to the network segment on which it resides to monitor the UPS. This means anyone on the segment can view the entire contents of the monitor and support tabs. The card restr ...

  • Liebert Network Card - page 22

    Monitor Tab When you select the monitor tab, you are presented with Connected Device: and Connected Device Status: on the top of the left pane. The Folder list is at the bottom of the pane under Device Information:. The first page you will see every time you open a new Web connection to the card is the Power Flow folder in the monitor tab. After yo ...

  • Liebert Network Card - page 23

    Clicking on the Battery, Output, Input, Bypass (not supported in Power- Sure Interactive UPSs), or Internals folder replaces the summary data presented on the graphical power flow pane with a tabular view of the complete list of data points reported by the UPS. Clicking on the Input folder presents a screen similar to: In the tabular view data, lik ...

  • Liebert Network Card - page 24

    Control Tab When you select the control tab, you are presented with Connected Device: and Connected Device Status: on the top of the left pane. The Folder list is at the bottom of the pane under Control Operations:. As detailed in the Web Security section, a Username and Password pro- tect the folders in the control tab. From the control tab you ca ...

  • Liebert Network Card - page 25

    Configure Tab When you select the configure tab, you are presented with Connected Device: and Connected Device Status: on the top of the left pane. The Folder list is at the bottom of the pane under Configuration Categories:. As detailed in the Web Security section, a Username and Password pro- tect the folders in the configure tab. When you click ...

  • Liebert Network Card - page 26

    SNMP Clicking on the SNMP folder allows you to enable authentication traps. Clicking on the Access or Traps folder allows you to configure the devices you want to have access to the card via SNMP and devices you want to receive traps from the card. The Access folder is shown below: As you are adding communities, you need to consider access rights. ...

  • Liebert Network Card - page 27

    Configure Tab - Making and Saving Configurations Similar to configuring the card using the Service Terminal, every time you make a configuration change, the card will have “save and reboot” for that change to take effect. As you navigate between the card's control web pages, you will notice that configuration screens include Edit and Save ...

  • Liebert Network Card - page 28

    Configure Tab - After Reinitialization Once card reinitialization is selected and confirmed, the card is unavail- able on the network. As the card reboots, it first begins communicating on the network and it will begin communicating with the UPS in which it is installed. The card will present to you some helpful information during the period of tim ...

  • Liebert Network Card - page 29

    Support Tab When you select the support tab, you are presented with Connected Device: and Connected Device Status: on the top of the left pane. A sin- gle device list is at the bottom of the pane under Support:. The support tab displays the Name, Location, and Description fields as well as relevant contact information for Liebert Technical Applicat ...

  • Liebert Network Card - page 30

    The OpenComms Web Card utilizes a SNMPv1 agent and is MIB-II com- pliant. The card supports the open standard UPS MIB RFC1628, with additional functionality and support through the Liebert Global Products MIB. A copy of the Liebert Global Products MIB is included on the CD included with your purchase. Likewise, the latest version of Libert Global P ...

  • Liebert Network Card - page 31

    MultiLink Support The most frequently asked question about configuring MultiLink to moni- tor a SNMP device, like the OpenComms Web Card, across the network is, what community string do I use? NOTE: Use the community string LiebertEM for MultiLink. Configuring for MultiLink support from the Service Terminal From the Main Menu, select option "3 ...

  • Liebert Network Card - page 32

    SL-52610 (9/02) Rev.2 ...

メーカー Liebert カテゴリー Network Card

Liebert Network Cardのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Network Cardの取扱説明書
- Liebertの製品カード
- パンフレット
- またはLiebert Network Cardの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Liebert Network Cardの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Liebert Network Cardの取り付け説明書、サービスマニュアル、簡易説明書、またはLiebert Network Cardのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Liebert Network Cardの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Liebert Network Cardデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLiebert Network Cardを使用するのを助ける技術的文書のことです。説明書は通常、全てのLiebert Network Cardユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Liebertの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Liebert Network Cardの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLiebert Network Cardの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Liebert Network Cardに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Liebert Network Cardデバイスの基本機能を使うにあたってのヒント。 Liebert Network Cardのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Liebert Network Cardに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLiebert Network Cardのメーカー/サービスへの連絡先に関する情報。

Liebert Network Cardについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLiebert Network Cardの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLiebert Network Cardで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)